AC output
- Continuous output
- 16 kW [1]
- AC configuration
- 230 V AC (L+N+PE) [2]
- AC output voltage
- ?
- AC frequency
- ?
- Grid pass-through
- 200 A [1]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- ?
- Maximum charge current
- 340 A [1]
- Maximum discharge current
- 340 A [1]
- Battery-only output
- ?
- Maximum grid charging
- 340 A [1]
- Compatible batteries / BMS
- Li-ion, lead-acid or user-defined batteries; Li-ion charging adapts to the BMS [1]
PV input
- PV array limit (connected)
- ?
- Maximum PV voltage (Voc)
- 600 V [2]
- MPPT voltage range
- 120 to 500 V [2]
- String inputs per MPPT
- 2+2+2 [1]
- PV current per MPPT
- ?
- PV short-circuit current
- 63 A [1]
- PV startup voltage
- 120 V [1]
Efficiency and modes
- Peak efficiency
- 97.6 % [2]
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- Generator input; max. generator bypass overload current 69.6A [1]
- Transfer time
- ?
- Idle consumption
- ?
- Parallel units
- 9 count [2]
Communication and environment
- Communications
- ?
- Operating temperature
- ?
- Operating noise
- ?
Mechanical
- Dimensions
- W 480 × H 860 × D 313 mm / W 18.9 × H 33.9 × D 12.3 in converted [2]
- Weight
- 64.7 kg / 143 lb converted [2]
Installation (from the manual)
Conductors
- Battery conductors
- 70mm²/ 00 [1]
- AC output conductors
- 85mm²/000 [1]
- PV conductors
- 6mm²/ 10 [1]
- Ground conductor
- ?
Protection
- Breakers / fuses
- Battery breaker 2P-200A; PV breaker 2P-50A; grid breaker 2P-250A; generator breaker 2P-100A; load breaker 2P-250A [1]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- ?
- PV disconnect
- ?
Not in the manual: Torque, Clearances and orientation, Grounding, Communication