AC output
- Continuous output
- 10 kW [1]
- AC configuration
- 230 V AC (Single phase) (200/208/220/240 V AC settable) [2]
- AC output voltage
- ?
- AC frequency
- 50/60Hz ± 0.3Hz [1]
- Grid pass-through
- 63 A [1]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- ?
- Maximum charge current
- 200 A [1]
- Maximum discharge current
- ?
- Battery-only output
- ?
- Maximum grid charging
- 120 A [1]
- Compatible batteries / BMS
- Li-ion, lead-acid or user-defined batteries [1]
PV input
- PV array limit (connected)
- ?
- PV input limit (converted)
- ?
- Maximum PV voltage (Voc)
- 500 V [2]
- MPPT voltage range
- 125 to 425 V [2]
- String inputs per MPPT
- ?
- PV current per MPPT
- ?
- PV short-circuit current
- 37 A [1]
- PV startup voltage
- ?
Efficiency and modes
- Peak efficiency
- 97.5 % [2]
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- Generator input; max. generator charging current 60A [1]
- Transfer time
- typical: 10 [1]
- Idle consumption
- ?
- Parallel units
- 6 count [2]
Communication and environment
- Communications
- ?
- Operating temperature
- ?
- Operating noise
- ?
Mechanical
- Dimensions
- 670 × 440 × 240 mm / 26.4 × 17.3 × 9.45 in converted [2]
- Weight
- 37 kg / 82 lb converted [2]
Installation (from the manual)
Conductors
- Battery conductors
- 42mm²/ 1 AWG [1]
- AC output conductors
- 13mm2/6AWG (L/N) [1]
- PV conductors
- 5mm²/ 10 AWG [1]
- Ground conductor
- ?
Protection
- Breakers / fuses
- Battery breaker 2P-250A; PV breaker 2P-25A; AC input, generator and AC output breakers 2P-63A [1]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- ?
- PV disconnect
- ?
Not in the manual: Torque, Clearances and orientation, Grounding, Communication