AC output
- Continuous output
- 10 kW [1]
- AC configuration
- Three-phase [1]
- AC output voltage
- 400 V [2]
- Grid pass-through
- 29 A [3]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- ?
- Maximum charge current
- 220 A [3]
- Maximum discharge current
- ?
- Battery-only output
- ?
- Maximum grid charging
- 120 A [3]
- Compatible batteries / BMS
- Li-ion, lead-acid or user-defined batteries [3]
PV input
- PV array limit (connected)
- 7500W/7500W [3]
- PV input limit (converted)
- ?
- Maximum PV voltage (Voc)
- 800 V [1]
- MPPT voltage range
- 200 to 650 [2]
- String inputs per MPPT
- ?
- PV current per MPPT
- 22/22A [3]
- PV short-circuit current
- ?
- PV startup voltage
- ?
Efficiency and modes
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- Generator input; max. utility/generator charging current 120A [3]
- Transfer time
- typical: 10 [3]
- Idle consumption
- ?
- Parallel units
- 6 count [1]
Communication and environment
- Communications
- RS485; CAN; USB; Dry contact; Wi-Fi (optional); GPRS (optional) [3]
- Operating temperature
- -10 to 55 C / 14 to 131 °F converted [3]
- Operating noise
- ?
Mechanical
- Dimensions
- 620 × 445 × 130 mm / 24.4 × 17.5 × 5.12 in converted [1]
- Weight
- 27 kg / 60 lb converted [1]
Installation (from the manual)
Conductors
- Battery conductors
- 42mm²/ 1 AWG [3]
- AC output conductors
- 7mm²/8 AWG(L1/L2/L3/N) [3]
- PV conductors
- 5mm²/ 10 AWG [3]
- Ground conductor
- ?
Protection
- Breakers / fuses
- Battery breaker 2P-250A; PV breaker 2P-25A; AC input and output breakers 4P-40A [3]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- ?
- PV disconnect
- ?
Not in the manual: Torque, Clearances and orientation, Grounding, Communication