AC output
- Continuous output
- 3.5 kW [1]
- Peak output
- 2 × rated power, 5s [1]
- AC configuration
- 110/120 V AC (L+N+PE) [1]
- AC output voltage
- ?
- AC frequency
- ?
- Grid pass-through
- 40 A [2]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- ?
- Maximum charge current
- ?
- Maximum discharge current
- ?
- Battery-only output
- ?
- Maximum grid charging
- 80 A [2]
- Compatible batteries / BMS
- Lead-acid or lithium batteries [2]
PV input
- PV array limit (connected)
- ?
- Maximum PV voltage (Voc)
- 500 V [1]
- MPPT voltage range
- 60 to 450 V [1]
- String inputs per MPPT
- ?
- PV current per MPPT
- ?
- PV short-circuit current
- ?
- PV startup voltage
- ?
Efficiency and modes
- Peak efficiency
- ?
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- ?
- Transfer time
- typical: 10 [2]
- Idle consumption
- ?
- Parallel units
- 6 count [1]
Communication and environment
- Communications
- ?
- Operating temperature
- ?
- Operating noise
- ?
Mechanical
- Dimensions
- 360.7 × 289.6 × 139.7 mm / 14.2 × 11.4 × 5.5 in converted [1]
- Weight
- 9.07 kg / 20 lb converted [1]
Installation (from the manual)
Conductors
- Battery conductors
- 33mm2/2AWG [2]
- AC output conductors
- 10mm2/7AWG [2]
- PV conductors
- 3mm2/12AWG (two inputs) or 5mm2/10AWG (single input) [2]
- Ground conductor
- ?
Protection
- Breakers / fuses
- Battery breaker 2P—125A; PV breaker 2P—25A (two inputs) or 2P—32A (single input); AC input and output breakers 2P—40A [2]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- ?
- PV disconnect
- ?
Not in the manual: Torque, Clearances and orientation, Grounding, Communication