AC output
- Continuous output
- 6 kW [1]
- Peak output
- 2 times of rated power,10s [2]
- AC configuration
- 230 V AC (200/208/220/230/240 V AC Settable) [2]
- AC output voltage
- ?
- AC frequency
- ?
- Grid pass-through
- 40 A [1]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- ?
- Maximum charge current
- 135 A [1]
- Maximum discharge current
- 135 A [1]
- Battery-only output
- ?
- Maximum grid charging
- 135 A [1]
- Compatible batteries / BMS
- Lithium-ion, lead-acid or user-defined batteries [1]
PV input
- PV array limit (connected)
- 12 kW [2]
- PV input limit (converted)
- ?
- Maximum PV voltage (Voc)
- 500 V [2]
- MPPT voltage range
- 65 to 450 V [2]
- String inputs per MPPT
- ?
- PV current per MPPT
- ?
- PV short-circuit current
- 33 A [1]
- PV startup voltage
- 60 V [1]
Efficiency and modes
- Peak efficiency
- 97.5 % [2]
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- Generator input; max. grid/generator charging current 135A [1]
- Transfer time
- typical: 10 [1]
- Idle consumption
- ?
- Parallel units
- 6 count [2]
Communication and environment
- Communications
- ?
- Operating temperature
- ?
- Operating noise
- ?
Mechanical
- Dimensions
- 300 × 460 × 217.5 mm / 11.8 × 18.1 × 8.56 in converted [2]
- Weight
- 17.5 kg / 38.6 lb converted [2]
Installation (from the manual)
Conductors
- Battery conductors
- 1AWG/43mm² [1]
- AC output conductors
- 8AWG/10mm² [1]
- PV conductors
- 10AWG/6mm² [1]
- Ground conductor
- ?
Protection
- Breakers / fuses
- Battery breaker 2P-200A; PV breaker 2P-25A; grid, generator and load breakers 2P-40A [1]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- ?
- PV disconnect
- ?
Not in the manual: Torque, Clearances and orientation, Grounding, Communication