AC output
- Continuous output
- 6 kW [1]
- AC configuration
- 120/240 V AC (single-phase/split-phase) [2]
- AC output voltage
- 240 V [2]
- Grid pass-through
- 40 A [1]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- 40 to 60 V [1]
- Maximum charge current
- 140 A [1]
- Maximum discharge current
- ?
- Battery-only output
- ?
- Maximum grid charging
- 80 A [1]
- Compatible batteries / BMS
- Lithium-ion, lead-acid or user-defined batteries [1]
PV input
- PV array limit (connected)
- 4500W+4500W [1]
- PV input limit (converted)
- ?
- Maximum PV voltage (Voc)
- 550 V [2]
- MPPT voltage range
- 150 to 450 [2]
- String inputs per MPPT
- ?
- PV current per MPPT
- 18/18 A [1]
- PV short-circuit current
- ?
- PV startup voltage
- ?
Efficiency and modes
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- Generator input; max. mains/generator charging current 80A [1]
- Transfer time
- typical: 10 [1]
- Idle consumption
- ?
- Parallel units
- 6 count [2]
Communication and environment
- Communications
- RS485; CAN; USB; Dry contact; Wi-Fi (optional); GPRS (optional) [1]
- Operating temperature
- -10 to 55 C / 14 to 131 °F converted [1]
- Operating noise
- ?
Mechanical
- Dimensions
- 648 × 410 × 140 mm / 25.5 × 16.1 × 5.51 in converted [2]
- Weight
- 21.7 kg / 47.8 lb converted [2]
Installation (from the manual)
Conductors
- Battery conductors
- 35mm2/2AWG [1]
- AC output conductors
- 10mm2/8AWG (L1/L2/N) split phase; 10mm2/8AWG (L1/L2) and 16mm2/6AWG (N) single phase [1]
- PV conductors
- 4mm2/12AWG [1]
- Ground conductor
- ?
Protection
- Breakers / fuses
- Battery breaker 2P-160A; PV breaker 2P-25A; AC input, generator and output breakers 3P-40A (split phase) or 2P-80A (single phase) [1]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- ?
- PV disconnect
- ?
Not in the manual: Torque, Clearances and orientation, Grounding, Communication