Charged ReviewsSaved 0Compare 0Login
Solis S6-EH3P49K-H-ND
Solis
Three-phase inverter

Solis S6-EH3P49K-H-ND

Key specs

Continuous output49 kW
Weight73 kg / 160 lb converted
Max PV voltage1,000 V
Efficiency97.8 %
Weighted efficiency97.4 %
PV start voltage180 V

All specifications

Identity

BrandSolis · Website
ModelS6-EH3P49K-H-ND
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Weight73 kg / 160 lb converted
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Weight" with "73kg" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 81, Technical Data table, General data, "Weight" row, S6-EH3P49K-H-ND column
[1]
MPPT count4
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "MPPT number/Max input strings number" with "4/8" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH3P49K-H-ND column
[1]
Peak output1.6 times of rated power, 2 S
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max. apparent output power" with "1.6 times of rated power, 2 S" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. This is the back-up output row. Read on September 25, 2026.
Where: User manual PDF page 80, Technical Data table, Output AC(Back-up), "Max. apparent output power" row, S6-EH3P49K-H-ND column
[1]
Max charge70 A
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max. charge / discharge current" with "70A*2" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Battery, "Max. charge / discharge current" row, S6-EH3P49K-H-ND column
[1]
DimensionsW 530 × H 880 × D 290 mm / W 20.9 × H 34.6 × D 11.4 in converted
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Dimensions(W/H/D)" with "530*880*290mm" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Recorded as width x height x depth in millimeters. Read on September 25, 2026.
Where: User manual PDF page 81, Technical Data table, General data, "Dimensions(W/H/D)" row, S6-EH3P49K-H-ND column
[1]
Efficiency97.8 %
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max. efficiency" with "97.8%" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 80, Technical Data table, Efficiency, "Max. efficiency" row, S6-EH3P49K-H-ND column
[1]
MPPT voltage150 to 850 V
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "MPPT voltage range" with "150-850V" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Input DC (PV side), "MPPT voltage range" row, S6-EH3P49K-H-ND column
[1]
PV input count8
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "MPPT number/Max input strings number" with "4/8" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH3P49K-H-ND column
[1]
Solar array98 kW
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Recommended Max PV array size" with "98kW" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Input DC (PV side), "Recommended Max PV array size" row, S6-EH3P49K-H-ND column
[1]
Solar input96 kW
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max Usable PV Input Power" with "96kW" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Input DC (PV side), "Max Usable PV Input Power" row, S6-EH3P49K-H-ND column
[1]
Max discharge70 A
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max. charge / discharge current" with "70A*2" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Battery, "Max. charge / discharge current" row, S6-EH3P49K-H-ND column
[1]
AC configurationThree-phase
Phase configuration stated in the manufacturer document.
Where: PDF physical pages 1-2; explicit family phase/topology description
[1]
Enclosure ratingIP66
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Ingress protection" with "IP66" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 81, Technical Data table, General data, "Ingress protection" row, S6-EH3P49K-H-ND column
[1]
Max PV current40 A
Per MPPT
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max. input current" with "40A/40A/40A/40A" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Input DC (PV side), "Max. input current" row, S6-EH3P49K-H-ND column
[1]
Max PV voltage1,000 V
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max. input voltage" with "1000V" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Input DC (PV side), "Max. input voltage" row, S6-EH3P49K-H-ND column
[1]
PV start voltage180 V
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Start-up voltage" with "180V" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Input DC (PV side), "Start-up voltage" row, S6-EH3P49K-H-ND column
[1]
Max charge power53.9 kW
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max. charge / discharge power" with "53.9kW" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Battery, "Max. charge / discharge power" row, S6-EH3P49K-H-ND column
[1]
Continuous output49 kW
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Rated output power" with "49kW" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Output AC(Grid side), "Rated output power" row, S6-EH3P49K-H-ND column
[1]
Battery efficiency97.5 %
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "BAT charged/discharged to AC Max. efficiency" with "97.5%" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 80, Technical Data table, Efficiency, "BAT charged/discharged to AC Max. efficiency" row, S6-EH3P49K-H-ND column
[1]
Max discharge power53.9 kW
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max. charge / discharge power" with "53.9kW" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Battery, "Max. charge / discharge power" row, S6-EH3P49K-H-ND column
[1]
Max PV short circuit60 A
Per MPPT
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Max. short circuit current" with "60A/60A/60A/60A" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Input DC (PV side), "Max. short circuit current" row, S6-EH3P49K-H-ND column
[1]
Battery voltage range150 to 800 V
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Battery Voltage range" with "150 - 800V" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 79, Technical Data table, Battery, "Battery Voltage range" row, S6-EH3P49K-H-ND column
[1]
Operating temperature-25 to 60 °C / -13 to 140 °F converted
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Operation temperature range" with "-25℃~+60℃" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 81, Technical Data table, General data, "Operation temperature range" row, S6-EH3P49K-H-ND column
[1]
Weighted efficiency97.4 %
EU weighted
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "EU efficiency" with "97.4%" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 80, Technical Data table, Efficiency, "EU efficiency" row, S6-EH3P49K-H-ND column
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
49 kW
Battery voltage
150 to 800 V
Solar input
98 kWMPPT trackers 4MPPT range 150 to 850 V
AC output
Three-phase
Warranty
5 years
Size
135.26 L* (Calculated from published dimensions)W: 530 × H: 880 × D: 290 mm / W: 20.9 × H: 34.6 × D: 11.4 inWeight 73 kg / 160 lb

Evidence score

21/100Missing details45% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term5 years6.0 / 30.0

5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Warranty" with "5 years (Extendable to 20 years)" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026.

[1]

Battery conversion efficiency97.5 %14.9 / 15.0

97.5 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10

The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "BAT charged/discharged to AC Max. efficiency" with "97.5%" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.

[1]

Research pending, 0 points: Certificates, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 15 to 50 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Warranty term5 years
The Technical Data table of the Solis S6-EH3P(15-30)K-H-LV-ND EUR user manual (file version V1,2(20250630)) prints the row "Warranty" with "5 years (Extendable to 20 years)" for S6-EH3P49K-H-ND. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026.
Where: User manual PDF page 81, Technical Data table, Features, "Warranty" row, S6-EH3P49K-H-ND column
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Solis user manualOfficial · Solis · Official user manual · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF physical page 1; literal model S6-EH3P15K-H-LV-ND in manufacturer model list/table

    Retrieved Sep 15, 2026

    SHA-256: 85b73462230a7d4297619b4d3fdb4e5ac7267922d82abb773ffc2cda424d9d8d

    Archived copies

    Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 4.62 MB

    Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EH3P(15-30)K-H-LV-ND_EUR_V1,2(20250630).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    86

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 85b73462230a7d4297619b4d3fdb4e5ac7267922d82abb773ffc2cda424d9d8d

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Solis user manual

Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 4.62 MB

Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EH3P(15-30)K-H-LV-ND_EUR_V1,2(20250630).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
86

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 85b73462230a7d4297619b4d3fdb4e5ac7267922d82abb773ffc2cda424d9d8d

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
S6-EH3P49K-H-ND

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 45
basis: Unknown
missing:
Certificate evidence needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 5
unit: Unknown
shown: 5 years
shown detail: Unknown
state: documented
points: 6
ceiling: 30
weight: 30
share: 20
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: efficiency
label: Battery conversion efficiency
value: 97.5
unit: Unknown
shown: 97.5 %
shown detail: Unknown
state: documented
points: 14.9
ceiling: 15
weight: 15
share: 99.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Solis user manual (Solis · manufacturer · observed Sep 15, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details