The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Weight" with "23.5kg" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 67, Technical Data table, General data, "Weight" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "MPPT number/Max input strings number" with "2/2" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. apparent output power" with "2 times of rated power, 10 S" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. This is the back-up output row. Read on September 25, 2026.
Where: User manual PDF page 66, Technical Data table, Output AC(Back-up), "Max. apparent output power" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. charge / discharge current" with "135A" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Battery, "Max. charge / discharge current" row, S6-EH1P6K-L-PLUS column
W 335 × H 560 × D 253 mm / W 13.2 × H 22 × D 9.96 in converted
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Dimensions(W/H/D)" with "335*560*253mm" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Recorded as width x height x depth in millimeters. Read on September 25, 2026.
Where: User manual PDF page 67, Technical Data table, General data, "Dimensions(W/H/D)" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. efficiency" with "96.2%" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 66, Technical Data table, Efficiency, "Max. efficiency" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "MPPT voltage range" with "90-435V" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Input DC (PV side), "MPPT voltage range" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "MPPT number/Max input strings number" with "2/2" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max Usable PV Input Power" with "9600W" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Input DC (PV side), "Max Usable PV Input Power" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. charge / discharge current" with "135A" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Battery, "Max. charge / discharge current" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Rated output voltage" with "1/N/PE, 220 V/230 V" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 66, Technical Data table, Output AC(Back-up), "Rated output voltage" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Ingress protection" with "IP66" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 67, Technical Data table, General data, "Ingress protection" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. input current" with "16A/16A" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Input DC (PV side), "Max. input current" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. input voltage" with "500V" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Input DC (PV side), "Max. input voltage" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Start-up voltage" with "90V" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Input DC (PV side), "Start-up voltage" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. charge / discharge power" with "6kW" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Battery, "Max. charge / discharge power" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Rated output power" with "6kW" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Output AC(Grid side), "Rated output power" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. charge / discharge power" with "6kW" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Battery, "Max. charge / discharge power" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. short circuit current" with "20A/20A" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Input DC (PV side), "Max. short circuit current" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Battery Voltage range" with "40 - 60V" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 65, Technical Data table, Battery, "Battery Voltage range" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Operation temperature range" with "-40℃~+60℃" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 67, Technical Data table, General data, "Operation temperature range" row, S6-EH1P6K-L-PLUS column
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "EU efficiency" with "96.1%" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 66, Technical Data table, Efficiency, "EU efficiency" row, S6-EH1P6K-L-PLUS column
47.46 L* (Calculated from published dimensions)W: 335 × H: 560 × D: 253 mm / W: 13.2 × H: 22 × D: 9.96 inWeight23.5 kg / 51.8 lb
Evidence score
6/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Warranty" with "5 years standard (extend to 20 years)" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
EN 61000-6-2/-3manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EH1P6K-L-PLUS
Limitations
The Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
IEC/EN 62109-1/-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EH1P6K-L-PLUS
Limitations
The Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Warranty" with "5 years standard (extend to 20 years)" for S6-EH1P6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026.
Where: User manual PDF page 67, Technical Data table, Features, "Warranty" row, S6-EH1P6K-L-PLUS column
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
1 on file
Manuals
PDF
Solis user manualOfficial · Solis · Official user manual · PDFCertificate & compliance claims (2)
IEC/EN 62109-1/-2Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
EN 61000-6-2/-3Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Solis user manual
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].