Charged ReviewsSaved 0Compare 0Login
Solis S6-EH1P4.6K-L-PLUS
Solis
Hybrid inverter

Solis S6-EH1P4.6K-L-PLUS

Key specs

Weight23 kg / 51 lb converted
Continuous output4.6 kW
Max PV voltage500 V
Efficiency96.2 %
Max charge105 A
MPPT count2

All specifications

Identity

BrandSolis · Website
ModelS6-EH1P4.6K-L-PLUS
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Weight23 kg / 51 lb converted
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Weight" with "23.0kg" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Read on September 25, 2026.
Where: User manual PDF page 64, Technical Data table, General data, "Weight" row, S6-EH1P4.6K-L-PLUS column
[1]
MPPT count2
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "MPPT number/Max input strings number" with "2/2" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH1P4.6K-L-PLUS column
[1]
Peak output2 times of rated power, 10 S
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. apparent output power" with "2 times of rated power, 10 S" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. This is the back-up output row. Read on September 25, 2026.
Where: User manual PDF page 63, Technical Data table, Output AC(Back-up), "Max. apparent output power" row, S6-EH1P4.6K-L-PLUS column
[1]
Max charge105 A
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. charge / discharge current" with "105A" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Battery, "Max. charge / discharge current" row, S6-EH1P4.6K-L-PLUS column
[1]
DimensionsW 335 × H 560 × D 253 mm / W 13.2 × H 22 × D 9.96 in converted
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Dimensions(W/H/D)" with "335*560*253mm" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Recorded as width x height x depth in millimeters. Read on September 25, 2026.
Where: User manual PDF page 64, Technical Data table, General data, "Dimensions(W/H/D)" row, S6-EH1P4.6K-L-PLUS column
[1]
Efficiency96.2 %
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. efficiency" with "96.2%" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 63, Technical Data table, Efficiency, "Max. efficiency" row, S6-EH1P4.6K-L-PLUS column
[1]
MPPT voltage90 to 435 V
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "MPPT voltage range" with "90-435V" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Input DC (PV side), "MPPT voltage range" row, S6-EH1P4.6K-L-PLUS column
[1]
PV input count2
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "MPPT number/Max input strings number" with "2/2" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH1P4.6K-L-PLUS column
[1]
Solar input7.36 kW
Converted: 7360 W / 1000 = 7.36 kW
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max Usable PV Input Power" with "7360W" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Input DC (PV side), "Max Usable PV Input Power" row, S6-EH1P4.6K-L-PLUS column
Sources
Converted: 7360 W / 1000 = 7.36 kW
[1]
Max discharge105 A
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. charge / discharge current" with "105A" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Battery, "Max. charge / discharge current" row, S6-EH1P4.6K-L-PLUS column
[1]
AC configurationSingle-phase 1/N/PE, 220 V/230 V
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Rated output voltage" with "1/N/PE, 220 V/230 V" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Read on September 25, 2026.
Where: User manual PDF page 63, Technical Data table, Output AC(Back-up), "Rated output voltage" row, S6-EH1P4.6K-L-PLUS column
[1]
Enclosure ratingIP66
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Ingress protection" with "IP66" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Read on September 25, 2026.
Where: User manual PDF page 64, Technical Data table, General data, "Ingress protection" row, S6-EH1P4.6K-L-PLUS column
[1]
Max PV current16 A
Per MPPT
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. input current" with "16A/16A" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Input DC (PV side), "Max. input current" row, S6-EH1P4.6K-L-PLUS column
[1]
Max PV voltage500 V
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. input voltage" with "500V" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Input DC (PV side), "Max. input voltage" row, S6-EH1P4.6K-L-PLUS column
[1]
PV start voltage90 V
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Start-up voltage" with "90V" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Input DC (PV side), "Start-up voltage" row, S6-EH1P4.6K-L-PLUS column
[1]
Max charge power4.6 kW
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. charge / discharge power" with "4.6kW" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Battery, "Max. charge / discharge power" row, S6-EH1P4.6K-L-PLUS column
[1]
Continuous output4.6 kW
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Rated output power" with "4.6kW" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Output AC(Grid side), "Rated output power" row, S6-EH1P4.6K-L-PLUS column
[1]
Max discharge power4.6 kW
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. charge / discharge power" with "4.6kW" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Battery, "Max. charge / discharge power" row, S6-EH1P4.6K-L-PLUS column
[1]
Max PV short circuit20 A
Per MPPT
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Max. short circuit current" with "20A/20A" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Input DC (PV side), "Max. short circuit current" row, S6-EH1P4.6K-L-PLUS column
[1]
Battery voltage range40 to 60 V
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Battery Voltage range" with "40 - 60V" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Read on September 25, 2026.
Where: User manual PDF page 62, Technical Data table, Battery, "Battery Voltage range" row, S6-EH1P4.6K-L-PLUS column
[1]
Operating temperature-40 to 60 °C / -40 to 140 °F converted
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Operation temperature range" with "-40℃~+60℃" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Read on September 25, 2026.
Where: User manual PDF page 64, Technical Data table, General data, "Operation temperature range" row, S6-EH1P4.6K-L-PLUS column
[1]
Weighted efficiency96.1 %
EU weighted
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "EU efficiency" with "96.1%" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 63, Technical Data table, Efficiency, "EU efficiency" row, S6-EH1P4.6K-L-PLUS column
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
4.6 kW
Battery voltage
40 to 60 V
Solar input
7.36 kWMPPT trackers 2MPPT range 90 to 435 V
AC output
Single-phase 1/N/PE, 220 V/230 V
Warranty
5 years
Size
47.46 L* (Calculated from published dimensions)W: 335 × H: 560 × D: 253 mm / W: 13.2 × H: 22 × D: 9.96 inWeight 23 kg / 51 lb

Evidence score

6/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term5 years6.0 / 30.0

5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Warranty" with "5 years standard (extend to 20 years)" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. The extension terms are not stated on this page. Read on September 25, 2026.

[1]

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
EN 61000-6-2/-3manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EH1P4.6K-L-PLUS
Limitations
The Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC/EN 62109-1/-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EH1P4.6K-L-PLUS
Limitations
The Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

FieldValueConditionsSource
Warranty term5 years
The Technical Data table of the Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints the row "Warranty" with "5 years standard (extend to 20 years)" for S6-EH1P4.6K-L-PLUS. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS columns. The extension terms are not stated on this page. Read on September 25, 2026.
Where: User manual PDF page 64, Technical Data table, Features, "Warranty" row, S6-EH1P4.6K-L-PLUS column
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Solis user manualOfficial · Solis · Official user manual · PDF
    Certificate & compliance claims (2)
    IEC/EN 62109-1/-2Manufacturer claim · equipment listingClaimedListed when checked

    The Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.

    Manufacturer document

    Official user manual: Solis user manual
    EN 61000-6-2/-3Manufacturer claim · equipment listingClaimedListed when checked

    The Solis S6-EH1P(3-8)K-L-PLUS EUR user manual (file version V1,3(20260402)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P4.6K-L-PLUS, S6-EH1P5K-L-PLUS). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.

    Manufacturer document

    Official user manual: Solis user manual
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF physical page 1; literal model S6-EH1P3.6K-L-PLUS in manufacturer model list/table

    Retrieved Sep 15, 2026

    SHA-256: a5dec7a6923ea05235b45bcd8cb794a59381a9dc001929faf1e7b571da0b354e

    Archived copies

    Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 2.44 MB

    Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EH1P(3-8)K-L-PLUS_EUR_V1,3(20260402).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    75

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: a5dec7a6923ea05235b45bcd8cb794a59381a9dc001929faf1e7b571da0b354e

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Solis user manual

Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 2.44 MB

Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EH1P(3-8)K-L-PLUS_EUR_V1,3(20260402).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
75

Embedded dates are file metadata, not independent proof of publication.

SHA-256: a5dec7a6923ea05235b45bcd8cb794a59381a9dc001929faf1e7b571da0b354e

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
S6-EH1P4.6K-L-PLUS

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: IEC/EN 62109-1/-2 +1
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 5
unit: Unknown
shown: 5 years
shown detail: Unknown
state: documented
points: 6
ceiling: 30
weight: 30
share: 20
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Solis user manual (Solis · manufacturer · observed Sep 15, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details