Charged ReviewsSaved 0Compare 0Login
Solis S6-EH1P3.6K-L-EU
Solis
Hybrid inverter

Solis S6-EH1P3.6K-L-EU

Key specs

Weight24.18 kg / 53.31 lb converted
Continuous output3.6 kW
Max PV voltage600 V
Efficiency97 %
Max charge75 A
MPPT count2

All specifications

Identity

BrandSolis · Website
ModelS6-EH1P3.6K-L-EU
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Weight24.18 kg / 53.31 lb converted
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Weight" with "24.18kg" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Read on September 25, 2026.
Where: User manual PDF page 53, Technical Data table, General data, "Weight" row, S6-EH1P3.6K-L-EU column
[1]
MPPT count2
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "MPPT number/Max input strings number" with "2/2" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH1P3.6K-L-EU column
[1]
Peak output5 kVA, 60SEC
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Max. apparent output power" with "5 kVA, 60SEC" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. This is the back-up output row. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Output AC(Back-up), "Max. apparent output power" row, S6-EH1P3.6K-L-EU column
[1]
Max charge75 A
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Maximum Charge/discharge current" with "75A" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Battery, "Maximum Charge/discharge current" row, S6-EH1P3.6K-L-EU column
[1]
DimensionsW 405 × H 480 × D 205 mm / W 15.9 × H 18.9 × D 8.07 in converted
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Dimensions(W/H/D)" with "405*480*205mm" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Recorded as width x height x depth in millimeters. Read on September 25, 2026.
Where: User manual PDF page 53, Technical Data table, General data, "Dimensions(W/H/D)" row, S6-EH1P3.6K-L-EU column
[1]
Efficiency97 %
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Max efficiency" with ">97.0%" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 52, Technical Data table, Efficiency, "Max efficiency" row, S6-EH1P3.6K-L-EU column
[1]
MPPT voltage90 to 520 V
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "MPPT voltage range" with "90-520V" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Input DC (PV side), "MPPT voltage range" row, S6-EH1P3.6K-L-EU column
[1]
PV input count2
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "MPPT number/Max input strings number" with "2/2" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH1P3.6K-L-EU column
[1]
Solar array5.7 kW
Converted: 5700 W / 1000 = 5.7 kW
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Recommended max. PV power" with "5700W" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Input DC (PV side), "Recommended max. PV power" row, S6-EH1P3.6K-L-EU column
Sources
Converted: 5700 W / 1000 = 5.7 kW
[1]
Max discharge75 A
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Maximum Charge/discharge current" with "75A" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Battery, "Maximum Charge/discharge current" row, S6-EH1P3.6K-L-EU column
[1]
AC configurationSingle-phase 1/N/PE, 220 V/230 V
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Rated output voltage" with "1/N/PE, 220 V/230 V" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Output AC(Back-up), "Rated output voltage" row, S6-EH1P3.6K-L-EU column
[1]
Enclosure ratingIP66
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Ingress protection" with "IP66" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Read on September 25, 2026.
Where: User manual PDF page 53, Technical Data table, General data, "Ingress protection" row, S6-EH1P3.6K-L-EU column
[1]
Max PV current16 A
Per MPPT
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Max. input current" with "16A/16A" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Input DC (PV side), "Max. input current" row, S6-EH1P3.6K-L-EU column
[1]
Max PV voltage600 V
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Max. input voltage" with "600V" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Input DC (PV side), "Max. input voltage" row, S6-EH1P3.6K-L-EU column
[1]
PV start voltage90 V
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Start-up voltage" with "90V" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Input DC (PV side), "Start-up voltage" row, S6-EH1P3.6K-L-EU column
[1]
Max charge power3.6 kW
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Maximum Charging Power" with "3.6kW" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Battery, "Maximum Charging Power" row, S6-EH1P3.6K-L-EU column
[1]
Continuous output3.6 kW
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Rated output power" with "3.6kW" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 52, Technical Data table, Output AC(Grid side), "Rated output power" row, S6-EH1P3.6K-L-EU column
[1]
Max PV short circuit24 A
Per MPPT
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Max. short circuit current" with "24A/24A" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Input DC (PV side), "Max. short circuit current" row, S6-EH1P3.6K-L-EU column
[1]
Battery voltage range42 to 58 V
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Battery Voltage range" with "42 - 58V" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Read on September 25, 2026.
Where: User manual PDF page 51, Technical Data table, Battery, "Battery Voltage range" row, S6-EH1P3.6K-L-EU column
[1]
Operating temperature-25 to 60 °C / -13 to 140 °F converted
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Operation temperature range" with "-25℃~+60℃" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Read on September 25, 2026.
Where: User manual PDF page 53, Technical Data table, General data, "Operation temperature range" row, S6-EH1P3.6K-L-EU column
[1]
Weighted efficiency96.2 %
EU weighted
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "EU efficiency" with ">96.2%" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 52, Technical Data table, Efficiency, "EU efficiency" row, S6-EH1P3.6K-L-EU column
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
3.6 kW
Battery voltage
42 to 58 V
Solar input
5.7 kWMPPT trackers 2MPPT range 90 to 520 V
AC output
Single-phase 1/N/PE, 220 V/230 V
Warranty
5 years
Size
39.85 L* (Calculated from published dimensions)W: 405 × H: 480 × D: 205 mm / W: 15.9 × H: 18.9 × D: 8.07 inWeight 24.18 kg / 53.31 lb

Evidence score

6/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term5 years6.0 / 30.0

5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Warranty" with "5 years standard (extand to 20 years)" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. The extension terms are not stated on this page. Read on September 25, 2026.

[1]

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
EN 61000-6-1/-2/-3/-4manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EH1P3.6K-L-EU
Limitations
The Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints "IEC/EN 62109-1/-2, EN 61000-6-1/-2/-3/-4" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC/EN 62109-1/-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EH1P3.6K-L-EU
Limitations
The Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints "IEC/EN 62109-1/-2, EN 61000-6-1/-2/-3/-4" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

FieldValueConditionsSource
Warranty term5 years
The Technical Data table of the Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints the row "Warranty" with "5 years standard (extand to 20 years)" for S6-EH1P3.6K-L-EU. The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU columns. The extension terms are not stated on this page. Read on September 25, 2026.
Where: User manual PDF page 53, Technical Data table, Features, "Warranty" row, S6-EH1P3.6K-L-EU column
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Solis user manualOfficial · Solis · Official user manual · PDF
    Certificate & compliance claims (2)
    IEC/EN 62109-1/-2Manufacturer claim · equipment listingClaimedListed when checked

    The Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints "IEC/EN 62109-1/-2, EN 61000-6-1/-2/-3/-4" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.

    Manufacturer document

    Official user manual: Solis user manual
    EN 61000-6-1/-2/-3/-4Manufacturer claim · equipment listingClaimedListed when checked

    The Solis S6-EH1P(3-6)K-L-EU EUR user manual (file version V1,3(20250630)) prints "IEC/EN 62109-1/-2, EN 61000-6-1/-2/-3/-4" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P3K-L-EU, S6-EH1P3.6K-L-EU). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.

    Manufacturer document

    Official user manual: Solis user manual
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF physical page 1; literal model S6-EH1P3.6K-L-EU in manufacturer model list/table

    Retrieved Sep 15, 2026

    SHA-256: 0aaf5d89a8d6988f65c39300e105761cd079211d8d1bfeef3265f6b704a8081a

    Archived copies

    Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 4.78 MB

    Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EH1P(3-6)K-L-EU_EUR_V1,3(20250630).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    60

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 0aaf5d89a8d6988f65c39300e105761cd079211d8d1bfeef3265f6b704a8081a

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Solis user manual

Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 4.78 MB

Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EH1P(3-6)K-L-EU_EUR_V1,3(20250630).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
60

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 0aaf5d89a8d6988f65c39300e105761cd079211d8d1bfeef3265f6b704a8081a

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
S6-EH1P3.6K-L-EU

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: IEC/EN 62109-1/-2 +1
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 5
unit: Unknown
shown: 5 years
shown detail: Unknown
state: documented
points: 6
ceiling: 30
weight: 30
share: 20
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Solis user manual (Solis · manufacturer · observed Sep 15, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details