Charged ReviewsSaved 0Compare 0Login
Solis S6-EH1P10K-L-PLUS
Solis
Hybrid inverter

Solis S6-EH1P10K-L-PLUS

Key specs

Weight23.8 kg / 52.5 lb converted
Continuous output10 kW
Max PV voltage500 V
Efficiency96.2 %
Max charge210 A
MPPT count2

All specifications

Identity

BrandSolis · Website
ModelS6-EH1P10K-L-PLUS(21A)
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Weight23.8 kg / 52.5 lb converted
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Weight" with "23.8kg" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. Read on September 25, 2026.
Where: User manual PDF page 78, Technical Data table, General data, "Weight" row, S6-EH1P10K-L-PLUS(21A) column
[1]
MPPT count2
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "MPPT number/Max input strings number" with "2/4" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Peak output2 times of rated power, 10 S
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Max. apparent output power" with "2 times of rated power, 10 S" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. This is the back-up output row. Read on September 25, 2026.
Where: User manual PDF page 77, Technical Data table, Output AC(Back-up), "Max. apparent output power" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Max charge210 A
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Max. charge / discharge current" with "210A" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Battery, "Max. charge / discharge current" row, S6-EH1P10K-L-PLUS(21A) column
[1]
DimensionsW 335 × H 560 × D 253 mm / W 13.2 × H 22 × D 9.96 in converted
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Dimensions(W/H/D)" with "335*560*253mm" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. Recorded as width x height x depth in millimeters. Read on September 25, 2026.
Where: User manual PDF page 78, Technical Data table, General data, "Dimensions(W/H/D)" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Efficiency96.2 %
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Max. efficiency" with "96.2%" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 77, Technical Data table, Efficiency, "Max. efficiency" row, S6-EH1P10K-L-PLUS(21A) column
[1]
MPPT voltage90 to 435 V
Printed as "90-435V" on page 76 of the Solis S6-EH1P(9-10)K-L-PLUS(21A) user manual (V1.0, September 2025), in the technical data table for S6-EH1P9.9K-L-PLUS(21A) and S6-EH1P10K-L-PLUS(21A), where one value covers both models. Revised on 30 September 2026: The value is unchanged. The locator had pointed at pages 64 and 66, which are the S6-EH1P3K and 3.6K-L-PLUS(21A) tables; the same figure is printed for this model on its own table pages, and the locator now names them.
Where: User manual, 8. Specifications, page 76, "MPPT voltage range" row
[1]
PV input count4
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "MPPT number/Max input strings number" with "2/4" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Input DC (PV side), "MPPT number/Max input strings number" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Solar input16 kW
Converted: 16000 W / 1000 = 16 kW
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Max Usable PV Input Power" with "16000W" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Input DC (PV side), "Max Usable PV Input Power" row, S6-EH1P10K-L-PLUS(21A) column
Sources
Converted: 16000 W / 1000 = 16 kW
[1]
Max discharge210 A
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Max. charge / discharge current" with "210A" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. One figure is printed for charge and discharge. Where the cell prints a per-port figure times the number of battery ports, the value recorded is the per-port figure. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Battery, "Max. charge / discharge current" row, S6-EH1P10K-L-PLUS(21A) column
[1]
AC configurationSingle-phase 1/N/PE, 220 V/230 V
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Rated output voltage" with "1/N/PE, 220 V/230 V" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. Read on September 25, 2026.
Where: User manual PDF page 77, Technical Data table, Output AC(Back-up), "Rated output voltage" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Enclosure ratingIP66
Printed as "Ingress protection IP66" on page 78 of the Solis S6-EH1P(9-10)K-L-PLUS(21A) user manual (V1.0, September 2025), in the technical data table for S6-EH1P9.9K-L-PLUS(21A) and S6-EH1P10K-L-PLUS(21A), where one value covers both models. Revised on 30 September 2026: The value is unchanged. The locator had pointed at pages 64 and 66, which are the S6-EH1P3K and 3.6K-L-PLUS(21A) tables; the same figure is printed for this model on its own table pages, and the locator now names them.
Where: User manual, 8. Specifications, page 78, "Ingress protection" row
[1]
Max PV current42 A
Per MPPT
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Max. input current" with "42A/42A" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Input DC (PV side), "Max. input current" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Max PV voltage500 V
Printed as "500V" on page 76 of the Solis S6-EH1P(9-10)K-L-PLUS(21A) user manual (V1.0, September 2025), in the technical data table for S6-EH1P9.9K-L-PLUS(21A) and S6-EH1P10K-L-PLUS(21A), where one value covers both models. Revised on 30 September 2026: The value is unchanged. The locator had pointed at pages 64 and 66, which are the S6-EH1P3K and 3.6K-L-PLUS(21A) tables; the same figure is printed for this model on its own table pages, and the locator now names them.
Where: User manual, 8. Specifications, page 76, "Max. input voltage" row
[1]
PV start voltage90 V
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Start-up voltage" with "90V" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Input DC (PV side), "Start-up voltage" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Max charge power10 kW
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Max. charge / discharge power" with "10kW" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Battery, "Max. charge / discharge power" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Continuous output10 kW
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Rated output power" with "10kW" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Output AC(Grid side), "Rated output power" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Max discharge power10 kW
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Max. charge / discharge power" with "10kW" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Battery, "Max. charge / discharge power" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Max PV short circuit48 A
Per MPPT
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Max. short circuit current" with "48A/48A" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Input DC (PV side), "Max. short circuit current" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Battery voltage range40 to 60 V
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Battery Voltage range" with "40 - 60V" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. Read on September 25, 2026.
Where: User manual PDF page 76, Technical Data table, Battery, "Battery Voltage range" row, S6-EH1P10K-L-PLUS(21A) column
[1]
Operating temperature-40 to 60 °C / -40 to 140 °F converted
Printed as "-40℃~+60℃" on page 78 of the Solis S6-EH1P(9-10)K-L-PLUS(21A) user manual (V1.0, September 2025), in the technical data table for S6-EH1P9.9K-L-PLUS(21A) and S6-EH1P10K-L-PLUS(21A), where one value covers both models. Revised on 30 September 2026: The value is unchanged. The locator had pointed at pages 64 and 66, which are the S6-EH1P3K and 3.6K-L-PLUS(21A) tables; the same figure is printed for this model on its own table pages, and the locator now names them.
Where: User manual, 8. Specifications, page 78, "Operation temperature range" row
[1]
Weighted efficiency96.1 %
EU weighted
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "EU efficiency" with "96.1%" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. Where the cell prints a greater-than sign, the value recorded is the figure after it. Read on September 25, 2026.
Where: User manual PDF page 77, Technical Data table, Efficiency, "EU efficiency" row, S6-EH1P10K-L-PLUS(21A) column
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
10 kW
Battery voltage
40 to 60 V
Solar input
16 kWMPPT trackers 2MPPT range 90 to 435 V
AC output
Single-phase 1/N/PE, 220 V/230 V
Warranty
5 years
Size
47.46 L* (Calculated from published dimensions)W: 335 × H: 560 × D: 253 mm / W: 13.2 × H: 22 × D: 9.96 inWeight 23.8 kg / 52.5 lb

Evidence score

6/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term5 years6.0 / 30.0

5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Warranty" with "5 years standard (extend to 20 years)" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. The extension terms are not stated on this page. Read on September 25, 2026.

[1]

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
EN 61000-6-2/-3manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EH1P10K-L-PLUS
Limitations
The Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A)). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC/EN 62109-1/-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EH1P10K-L-PLUS
Limitations
The Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A)). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

FieldValueConditionsSource
Warranty term5 years
The Technical Data table of the Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints the row "Warranty" with "5 years standard (extend to 20 years)" for S6-EH1P10K-L-PLUS(21A). The PDF text layer lists the table's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell is shared by the S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A) columns. The extension terms are not stated on this page. Read on September 25, 2026.
Where: User manual PDF page 78, Technical Data table, Features, "Warranty" row, S6-EH1P10K-L-PLUS(21A) column
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Solis user manualOfficial · Solis · Official user manual · PDF
    Certificate & compliance claims (2)
    IEC/EN 62109-1/-2Manufacturer claim · equipment listingClaimedListed when checked

    The Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A)). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.

    Manufacturer document

    Official user manual: Solis user manual
    EN 61000-6-2/-3Manufacturer claim · equipment listingClaimedListed when checked

    The Solis S6-EH1P(9-10)K-L-PLUS(21A) EUR user manual (file version V1,0(20250916)) prints "IEC/EN 62109-1/-2, EN 61000-6-2/-3" in its Technical Data table, "Safty/EMC standard" row (one cell shared by S6-EH1P9.9K-L-PLUS(21A), S6-EH1P10K-L-PLUS(21A)). This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.

    Manufacturer document

    Official user manual: Solis user manual
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF physical page 1; literal model S6-EH1P10K-L-PLUS in manufacturer model list/table

    Retrieved Sep 15, 2026

    SHA-256: 5a6dc2a399b73bee77f91f92e744db847f2a3fe42a44124eb3cd54dbbdc3fde4

    Archived copies

    Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 2.80 MB

    Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EH1P(9-10)K-L-PLUS(21A)_EUR_V1,0(20250916).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    80

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 5a6dc2a399b73bee77f91f92e744db847f2a3fe42a44124eb3cd54dbbdc3fde4

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Solis user manual

Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 2.80 MB

Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EH1P(9-10)K-L-PLUS(21A)_EUR_V1,0(20250916).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
80

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 5a6dc2a399b73bee77f91f92e744db847f2a3fe42a44124eb3cd54dbbdc3fde4

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
S6-EH1P10K-L-PLUS(21A)

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: IEC/EN 62109-1/-2 +1
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 5
unit: Unknown
shown: 5 years
shown detail: Unknown
state: documented
points: 6
ceiling: 30
weight: 30
share: 20
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Solis user manual (Solis · manufacturer · observed Sep 15, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details