Sol-Ark Limitless 12K

Brand
Sol-Ark
Model
12K-2P-LL
SKU / part number
12K-2P-LL [1]
Category
Inverters

chargedreviews.com/inverters/sol-ark-limitless-12k-12k-2p-ll

AC output

Continuous output
12 kW [2]
Peak output
24000 W [3]
AC configuration
120/240 V Split-Phase [4]
AC output voltage
120/240 V (L-N/L-L); 120/208 V [3]
AC frequency
?
Grid pass-through
100 A [2]
Maximum output per leg
?

Battery

Battery voltage
48 V [2]
Battery voltage range
43 to 59 [2]
Maximum charge current
220 A [2]
Maximum discharge current
220 A [2]
Battery-only output
10 kW [2]
Maximum grid charging
?
Compatible batteries / BMS
The inverter can work with any battery chemistry as long as it remains within the range of 43 VDC to 59 VDC [4]

PV input

PV array limit (connected)
19.2 kW [2]
PV input limit (converted)
12 kW [2]
Maximum PV voltage (Voc)
500 V [2]
MPPT voltage range
150 to 425 [2]
MPPT trackers
3 [2]
String inputs per MPPT
2 [2]
PV current per MPPT
32 A [2]
PV short-circuit current
60 A [2]
PV startup voltage
125 V [2]

Efficiency and modes

Peak efficiency
97.6 % [1]
CEC weighted efficiency
?
Battery conversion efficiency
?
Grid / off-grid modes
?
Generator input
A generator or an AC-coupled source (58 A maximum or 14 kW), such as string or micro inverters, can be connected to the inverter’s GEN terminal [4]
Transfer time
5 ms [2]
Idle consumption
96 W [2]
Parallel units
12 [2]

Communication and environment

Communications
CANbus; RS485; MODBUS RTU [2]
Operating temperature
-40 to 60 [2]
Enclosure rating
IP65; NEMA3R [2]
Operating noise
?

Mechanical

Dimensions
W 421.4 × H 653 × D 249.5 mm / W 16.59 × H 25.7 × D 9.82 in converted [2]
Weight
29.5 kg / 65 lb converted [2]

Installation (from the manual)

Torque

Terminal torque
5.2 N·m [4]
AC terminal torque
3 N·m [4]
Battery terminal torque
5.2 N·m [4]
PV terminal torque
?
Ground terminal torque
3 N·m [4]

Conductors

Battery conductors
2/0 to 4/0 AWG [4]
AC input conductors
2 to 1 AWG (GRID terminal) [4]
AC output conductors
2 to 1 AWG (LOAD terminal) [4]
PV conductors
10 AWG [4]
Ground conductor
6-1 AWG [4]

Protection

AC input breaker
?
AC output breaker
?
Battery fuse or breaker
?
PV disconnect
PV DC disconnect [4]

Clearances and orientation

Installation clearances
There must be at least 6 in [15 cm] of vertical clearance and 2 in [5 cm] of side clearance for proper heat dissipation. [4]
Mounting orientation
?

Communication

Communication ports
BMS RJ45 terminals (RS485 / CAN); Parallel RJ45 terminals [4]

Not in the manual: Grounding

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Sol-Ark Limitless 12K · 12K-2P-LL

Warranty

Warranty term10 years[2]
Optional extension?
Coverage startsThe term of this warranty begins on the Product(s) initial purchase date, or the date of receipt of the Product(s) by the end user, whichever is later.[5]
Coverage conditionsExcludes damage from installation or removal, alteration or disassembly, normal wear and tear, accident or abuse, unauthorized firmware or software changes, corrosion, lightning (unless an EMP hardened system), unauthorized repair, operation contrary to instructions, fire, floods or acts of nature, shipping, damage caused by other system components, and altered or removed serial numbers. LCD screen and fans are covered for 5 years from date of purchase.[5]
RemedyRepair or replacement of the Product, at Sol-Ark discretion.[5]
Labor and shippingThis warranty does not cover the costs of installation, removal, shipping (except as described below), or reinstallation of Products or parts of Products.[5]
Transfer to another ownerApplies to the original purchaser and is transferable only if the Product remains installed in the original use location.[5]
Registration?
Territory?

Certifications and listings

UL 1741Claimed [1]
UL 1741 SA?
UL 1741 SBVerified listed as of snapshot [6]
IEEE 1547Claimed [2]
CA Rule 21?
UL 9540Claimed [2]
FCC Part 15?
CECVerified listed as of snapshot [6]
CECVerified listed as of snapshot [6]
CSA C22.2Claimed [2]
UL 1699BClaimed [1]
UL 1998Claimed [1]

Documents and sources

  1. Sol-Ark Limitless 12K datasheet manufacturer · Revised 2026-03 · Checked Sep 8, 2026 https://sol-ark.com/wp-content/uploads/2026/05/SA-12K-2P-LL_Datasheet_Rev1.1_PS-00045.pdf
  2. Sol-Ark 12K-2P-LL Datasheet Rev3 PS-00045 14July2026 Manufacturer datasheet · Checked Sep 9, 2026 https://sol-ark.com/wp-content/uploads/2026/05/12K-2P-LL_Datasheet_Rev3_PS-00045_14July2026.pdf
  3. 12K-2P-LL Datasheet V4.0 (EN) Datasheet · Checked Sep 19, 2026 https://sol-ark.com/wp-content/uploads/2026/09/12K-LL_Datasheet_PS-00045_Rev_4_9Sept2026.pdf
  4. Sol-Ark 12k-2p-ll Installation and user manual Manufacturer manual · Revision Rev3 · Revised Jul 16, 2026 · Checked Sep 10, 2026 https://sol-ark.com/wp-content/uploads/2026/05/12K-LL_Installation_Manual_MA-00057_Rev3_16July202.pdf
  5. Sol-Ark 12K-2P LL Limited Warranty PO-00021 Manufacturer warranty policy · Checked Sep 9, 2026 https://sol-ark.com/wp-content/uploads/2024/06/12K-2P_LL_Limited_Warranty_PO-00021.pdf
  6. CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) Government equipment list (spreadsheet) · Revision Data unchanged since October 1, 2026 · Revised Oct 1, 2026 · Checked Oct 10, 2026 https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=InvertersList

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/inverters/sol-ark-limitless-12k-12k-2p-llSome links pay us a commission. That does not affect what we record.