Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Total harmonic distortion (THD) at rated power < 5%". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Output power (surge) at 40°C 8.0 kVA (20 sec)". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Product weight 52.5 kg (116.0 lb)". No value was taken from another column or another part number.
Printed as "Output power (surge) at 40°C 8.0 kVA (20 sec) 9.0 kVA (15 sec) 12.0 kVA (15 sec)" in the Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz); the XW4024 120 240 60 column (part number 865-1010) reads "8.0 kVA (20 sec)". The rating is for 40°C ambient. Read on September 25, 2026.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "AC input voltage (nominal) 120 / 240 V split-phase". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Product dimensions (H x W x D) 58 x 41 x 23 cm". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Idle consumption (search mode) < 8 W". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Efficiency Peak 94.0%". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Total harmonic distortion (THD) at rated power < 5%". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Output power (surge) at 40°C 8.0 kVA (20 sec)". No value was taken from another column or another part number.
Printed as "Output power (surge) at 40°C 8.0 kVA (20 sec) 9.0 kVA (15 sec) 12.0 kVA (15 sec)" in the Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz); the XW4024 120 240 60 column (part number 865-1010) reads "8.0 kVA (20 sec)". The rating is for 40°C ambient. Read on September 25, 2026.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "AC input voltage (nominal) 120 / 240 V split-phase". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Efficiency Peak 94.0%". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Frequency 60 +/-0.1 Hz". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Typical transfer time 8 ms". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Input voltage limits 20 to 32 V". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "CEC weighted 91.0%". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Automatic transfer relay 60 A". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Product weight 52.5 kg (116.0 lb)". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Product dimensions (H x W x D) 58 x 41 x 23 cm". No value was taken from another column or another part number.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Idle consumption (search mode) < 8 W". No value was taken from another column or another part number.
Schneider Electric publishes this model's family at https://solar.se.com/us/en/product/conext-xw-120-240-60hz/ under the heading "Discontinued Product". The page does not publish a last-order date or a service-end date for part number 865-1010.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "NEMA degree of protection NEMA1R (indoor rating)". No value was taken from another column or another part number.
Printed as "Multiple-unit configurations Split-phase: up to four parallel units in 120/240 V." in the Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz), for every model in the table. The word "four" is recorded as 4. Read on September 25, 2026.
Read from Schneider Electric's datasheet at https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, from the column the sheet identifies as part number 865-1010. Printed: "Ambient air temperature for operation -25 to 70°C (power derated above 45°C)". No value was taken from another column or another part number.
Printed as "Safety UL1741, CSA 107.1 EMC FCC and Industry Canada Class B Interconnect IEEE 1547 and CSA 107.1" in the Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz). An EMC class with no rule part number printed; the numbered standards are recorded as certification claims. Read on September 25, 2026.
Published claims and calculations, not independent test results.
Documents
4 on file
PDF
Schneider Electric datasheetOfficialSchneider ElectricOfficial datasheetOctober 2, 2014
Certificate & compliance claims (3)
UL 1741Manufacturer claim · equipment listingClaimedStatus unconfirmed
Schneider Electric prints "UL 1741" in a certification, standards or compliance row on PDF page 2 of https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, a document this catalog already attaches to 865-1010; the value was located through the specification column headed 865-1010. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
CSA 107.1Manufacturer claim · equipment listingClaimedListed when checked
The Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz) prints "Safety UL1741, CSA 107.1 EMC FCC and Industry Canada Class B Interconnect IEEE 1547 and CSA 107.1" in its "Regulatory approval" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked
The Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz) prints "Safety UL1741, CSA 107.1 EMC FCC and Industry Canada Class B Interconnect IEEE 1547 and CSA 107.1" in its "Regulatory approval" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Conext XW Power System Installation Guide (975-0239-01-01 Rev F)OfficialSchneider ElectricOfficial instruction manual
Source details
Revision
Not stated
Revision date
Not stated
Location: Conext XW Power System Installation Guide (975-0239-01-01 Rev F)
Retrieved
Manufacturer document PDF preserved byte for byte from the link Schneider Electric publishes on https://solar.se.com/us/en/product/conext-xw-120-240-60hz/. It is attached as the document the manufacturer publishes for this family; no claim is made that it was reviewed clause by clause for part number 865-1010.
Archived copies
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Conext XW USA Contractual Warranty Statement v2.1OfficialSchneider ElectricOfficial warranty
Source details
Revision
Not stated
Revision date
Not stated
Location: Conext XW USA Contractual Warranty Statement v2.1
Retrieved
Manufacturer document PDF preserved byte for byte from the link Schneider Electric publishes on https://solar.se.com/us/en/product/conext-xw-120-240-60hz/. It is attached as the document the manufacturer publishes for this family; no claim is made that it was reviewed clause by clause for part number 865-1010.
Archived copies
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Schneider Electric reference document
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Conext XW Power System Installation Guide (975-0239-01-01 Rev F)
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Schneider Electric USA Conext XW Contractual Warranty Statement v2.1 (effective 2013.09.01) names part number 865-1010 in "Models: 865-1000-01, 865-1005, 865-1010, 865-1035-61, 865-1040-61, 865-1045-61", gives its geographic validity as "United States of America", and prints "Length of Warranty:" as "5 years unless applicable law requires a longer period in which case it will be that period of time". Coverage is defects in workmanship and materials from the date of purchase by the original end user; the statement is transferable for the unexpired portion. The datasheet itself prints "2 or 5 years" depending on the country of installation. Read on September 25, 2026.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
The Schneider Electric USA Conext XW Contractual Warranty Statement v2.1 (effective 2013.09.01) names part number 865-1010 in "Models: 865-1000-01, 865-1005, 865-1010, 865-1035-61, 865-1040-61, 865-1045-61", gives its geographic validity as "United States of America", and prints "Length of Warranty:" as "5 years unless applicable law requires a longer period in which case it will be that period of time". Coverage is defects in workmanship and materials from the date of purchase by the original end user; the statement is transferable for the unexpired portion. The datasheet itself prints "2 or 5 years" depending on the country of installation. Read on September 25, 2026.
Research pending, 0 points: Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
UL 1741Product / system scope unresolvedClaimedStatus unconfirmed
Schneider Electric prints "UL 1741" in a certification, standards or compliance row on PDF page 2 of https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, a document this catalog already attaches to 865-1010; the value was located through the specification column headed 865-1010. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
CSA 107.1Product / system scope unresolvedClaimedListed when checked
The Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz) prints "Safety UL1741, CSA 107.1 EMC FCC and Industry Canada Class B Interconnect IEEE 1547 and CSA 107.1" in its "Regulatory approval" row. This records the standard as the manufacturer prints it; Read on September 25, 2026.
IEEE 1547Product / system scope unresolvedClaimedListed when checked
The Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz) prints "Safety UL1741, CSA 107.1 EMC FCC and Industry Canada Class B Interconnect IEEE 1547 and CSA 107.1" in its "Regulatory approval" row. This records the standard as the manufacturer prints it; Read on September 25, 2026.
UL 1741Manufacturer claim · equipment listingClaimedStatus unconfirmed
Schneider Electric prints "UL 1741" in a certification, standards or compliance row on PDF page 2 of https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, a document this catalog already attaches to 865-1010; the value was located through the specification column headed 865-1010. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
CSA 107.1Manufacturer claim · equipment listingClaimedListed when checked
The Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz) prints "Safety UL1741, CSA 107.1 EMC FCC and Industry Canada Class B Interconnect IEEE 1547 and CSA 107.1" in its "Regulatory approval" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked
The Schneider Electric Conext XW series (120 / 240 V / 60 Hz) datasheet (DS20141002_ConextXW60Hz) prints "Safety UL1741, CSA 107.1 EMC FCC and Industry Canada Class B Interconnect IEEE 1547 and CSA 107.1" in its "Regulatory approval" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
865-1010
Manufacturer SKU 865-1010
Observed
UL 1741: claimed
Product / system scope unresolved. Schneider Electric prints "UL 1741" in a certification, standards or compliance row on PDF page 2 of https://solar.se.com/us/wp-content/uploads/sites/7/2021/11/conext-xw-60-datasheet-20141002_eng.pdf, a document this catalog already attaches to 865-1010; the value was located through the specification column headed 865-1010. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.