Charged Reviews · Quick reference
RUiXU RX-12K Split Phase Hybrid Inverter
- Brand
- RUiXU
- Model
- RX-12K
- Category
- Inverters

AC output
| Continuous output | ? |
|---|---|
| Peak output | 17100 VA for 10 s[3] |
| AC configuration | Split phase 120/240 V; 120/208 V service supported[2] |
| AC output voltage | 240 V[3] |
| AC frequency | 60 Hz[2] |
| Grid pass-through | ? |
| Maximum output per leg | ? |
Battery
| Battery voltage | ? |
|---|---|
| Battery voltage range | 40~60[2] |
| Maximum charge current | 240 A[2] |
| Maximum discharge current | 228 A[3] |
| Battery-only output | ? |
| Maximum grid charging | ? |
| Compatible batteries / BMS | ? |
PV input
| PV array limit (connected) | 17.1 kW[2] |
|---|---|
| PV input limit (converted) | ? |
| Maximum PV voltage (Voc) | 600 V[2] |
| MPPT voltage range | 90~550[2] |
| MPPT trackers | 4[2] |
| String inputs per MPPT | 1/1/1/1[3] |
| PV current per MPPT | 16 A[2] |
| PV short-circuit current | 19.2/ 19.2/ 19.2/ 19.2 A[3] |
| PV startup voltage | 100 V[2] |
Efficiency and modes
| Peak efficiency | 97.6 %[2] |
|---|---|
| CEC weighted efficiency | 97 %[2] |
| Battery conversion efficiency | ? |
| Grid / off-grid modes | It converts the solar power to grid-compliant AC power for home loads and export extra power to the grid[3] |
| Generator input | ? |
| Transfer time | 20 ms[2] |
| Idle consumption | ? |
| Standby consumption | 10 W[2] |
| Parallel units | ? |
Communication and environment
| Communications | RS232; RS485 (RJ45); DRM (RJ45); Wi-Fi; 4G; Bluetooth (LED + app)[2] |
|---|---|
| Operating temperature | -40 to 60 °C[2] |
| Enclosure rating | NEMA 4X (IP65)[2] |
| Operating noise | ? |
Mechanical
| Dimensions | 247 D × 470 W × 810 H mm[3] |
|---|---|
| Weight | 50 kg / 110.23 lb[2] |
Installation (from the manual)
Torque
| AC terminal torque | 62 in-lb(7.01 N·m*)[3] |
|---|---|
| Battery terminal torque | 80 in-lb(9.04 N·m*)[3] |
| PV terminal torque | ? |
| Ground terminal torque | 26.5 in-lb(2.99 N·m*)[3] |
Conductors
| Battery conductors | 2/0 AWG (0~12ft.); 4/0 AWG (12~20ft.)[3] |
|---|---|
| AC input conductors | 2/0AWG[3] |
| AC output conductors | 2/0AWG[3] |
| PV conductors | 10~12AWG[3] |
| Ground conductor | 2/0AWG[3] |
Protection
| AC input breaker | 240VAC/200A[3] |
|---|---|
| AC output breaker | 240VAC/200A[3] |
| Battery fuse or breaker | Integrated Bonded Bat. Breaker 300A[3] |
| PV disconnect | 600VDC/20A[3] |
Clearances and orientation
| Installation clearances | ? |
|---|---|
| Mounting orientation | Install the device vertically. Do not install it forward-tilted, horizontally or upside down.[3] |
Grounding
| Grounding and neutral-ground bonding | According to NEC requirements, N-G bonding is only allowed at the service entrance[3] |
|---|
Communication
| Communication ports | RS485; Wi-Fi; CAN[3] |
|---|
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.