Charged ReviewsSaved 0Compare 0Login
PowMr
Hybrid inverter

PowMr POW-SunSmart LVM12K 12kW 48V Split-Phase Hybrid Inverter

Key specs

Weight42 kg / 93 lb converted
Continuous output12 kW
Converted: 12000 W / 1000 W per kW = 12 kW
Max PV voltage550 V
Efficiency97.5 %
Max charge200 A
MPPT count2

All specifications

Identity

BrandPowMr · Website
ModelPOW-SunSmart LVM12K
MarketUnknown
Manufacturer SKUPOW-SunSmart LVM12K
About brandPowMr sells off-grid and hybrid solar inverters, MPPT and PWM solar charge controllers, LiFePO4 batteries and solar panels under its own name through its store at powmr.com.
SKU detail
locator: products[].variants[].sku, handle hybrid-inverter-charger-for-parallel-12kw-48vdc-110v-220v-split-phase
conditions: PowMr's storefront listing, captured on October 13, 2026, prints "sku":"POW-SunSmart LVM12K" for the single variant of this listing.
Sources: [1]
FieldValueConditionsSource
Weight42 kg / 93 lb converted
The manual prints "Weight 42kg" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 62 (printed page 59), Basic Data, Weight
[2]
MPPT count2
The manual prints "Num. of MPP Trackers 2" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 61 (printed page 58), PV Input, Num. of MPP Trackers
[2]
Peak output2 times rated power
The manual prints "Max. Peak Power 2 times rated power" in a cell spanning the LVM8K, LVM10K and LVM12K columns; no duration is printed.
Where: PDF page 61 (printed page 58), Inverter Output, Max. Peak Power
[2]
Max charge200 A
The manual prints "Max. Hybrid Charging Current 200A" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 61 (printed page 58), Battery, Max. Hybrid Charging Current
[2]
Dimensions750*440*240mm
The manual prints "Dimensions 750*440*240mm" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 62 (printed page 59), Basic Data, Dimensions
[2]
CommunicationsRS485; CAN; USB; Dry contact
The manual prints "Communication Port RS485 / CAN / USB / Dry contact" and "External Modules (Optional) Wi-Fi / GPRS" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 62 (printed page 59), Communication, Communication Port
[2]
Efficiency97.5 %
maximum; 96.5% CEC
The manual prints "Max Efficiency 97.5%" and "CEC Efficiency 96.5%" in a cell spanning the LVM8K, LVM10K and LVM12K columns; the maximum figure is recorded.
Where: PDF page 62 (printed page 59), Efficiency, Max Efficiency
[2]
MPPT voltage125 to 450 V
The manual prints "MPPT Voltage Range 125-450Vdc/125-450Vdc" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 62 (printed page 59), PV Input, MPPT Voltage Range
[2] [3]
Max AC charge120 A
The manual prints "Max. Grid Charging Current 120A" and "Max. Generator Charging Current 60A" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 61 (printed page 58), Battery, Max. Grid Charging Current
[2]
Max PV charge200 A
The manual prints "Max. PV Charging Current 200A" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 61 (printed page 58), Battery, Max. PV Charging Current
[2]
Output waveformPure sine wave
Printed as "Waveform Pure Sine Wave" in the maker's document "PowMr POW-SunSmart LVM8K, LVM10K and LVM12K user manual V1.1 (PDF, English)".
Where: PowMr POW-SunSmart LVM8K, LVM10K and LVM12K user manual V1.1 (PDF, English), PDF page 61, Waveform row; spec-table row
[2]
AC configuration120/240 V split phase; 120/208 V three phase; 50/60 Hz
The manual prints "Rated Output Voltage 120/240Vac (Split-phase); 120/208V (Three-phase)" and "Rated AC Frequency 50/60Hz" in a cell spanning the LVM8K, LVM10K and LVM12K columns, both settable.
Where: PDF page 61 (printed page 58), Inverter Output, Rated Output Voltage and Rated AC Frequency
[2]
Enclosure ratingIP65
The manual prints "Protection Degree IP65" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 62 (printed page 59), Basic Data, Protection Degree
[2]
Max PV current25 / 25 A
The manual prints "Max. Input Current 25A/25A" in a cell spanning the LVM8K, LVM10K and LVM12K columns, one figure for each tracker.
Where: PDF page 62 (printed page 59), PV Input, Max. Input Current
[2]
Max PV voltage550 V
The manual prints "Max. Voltage of Open Circuit 550Vdc/550Vdc" in a cell spanning the LVM8K, LVM10K and LVM12K columns; the product page prints "PV Max Voltage 550Vdc".
Where: PDF page 62 (printed page 59), PV Input, Max. Voltage of Open Circuit
[2] [3]
Nominal voltage48 V
The manual prints "Rated Battery Voltage 48Vdc" in a cell spanning the LVM8K, LVM10K and LVM12K columns; the product page prints "DC Output (V) 48".
Where: PDF page 61 (printed page 58), Battery, Rated Battery Voltage
[2] [3]
Grid passthrough63 A
The manual prints "Bypass Phase Current 63A" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 62 (printed page 59), Grid / Generator Input, Bypass Phase Current
[2]
Max parallel units6 count
The manual prints "Parallel Capacity 6" in a cell spanning the LVM8K, LVM10K and LVM12K columns; the product page prints "Parallel Capability (Units) 6".
Where: PDF page 61 (printed page 58), Inverter Output, Parallel Capacity
[2] [3]
PV start voltage125 V
The product page prints "PV Start Voltage 125Vdc"; the manual prints no start voltage.
Where: Product page Specifications, PV Start Voltage
[3]
Continuous output12 kW
Converted: 12000 W / 1000 W per kW = 12 kW
at 240 V; 10.4 kW at 208 V
The manual prints "Rated Output Power 8800W 10000W @240V 12000W @208V 10400W" in separate model columns; "@240V 12000W @208V 10400W" is the POW-SunSmart LVM12K column, and the 240 V figure is recorded. The product page prints "Rated Load Power (W) 12000". Manufacturer claim, not an independent test.
Where: PDF page 61 (printed page 58), 9 Parameter Table, Inverter Output, Rated Output Power
Sources
Converted: 12000 W / 1000 W per kW = 12 kW
[2] [3]
Battery compatibilityLi-ion, lead-acid or user-defined batteries
The manual prints "Battery Type Li-ion / Lead-Acid / User Defined" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 61 (printed page 58), Battery, Battery Type
[2]
Battery voltage range40 to 60 V
The manual prints "Voltage Range 40-60Vdc" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 61 (printed page 58), Battery, Voltage Range
[2]
Operating temperature-25 to 60 °C / -13 to 140 °F converted
derated above 45 °C
The manual prints "Operating Temperature Range -25~60℃, >45℃ derated" in a cell spanning the LVM8K, LVM10K and LVM12K columns.
Where: PDF page 62 (printed page 59), Basic Data, Operating Temperature Range
[2]
Other compliance claimsUL1741 & IEEE1547.1-2020, CEC, Rule 21, HECO; FCC 15 class B
The manual prints "Safety Standards UL1741&IEEE1547.1-2020, CEC, RULE 21, HECO" and "EMC FCC 15 class B" in a cell spanning the LVM8K, LVM10K and LVM12K columns; recorded as the maker's text, not checked against a listing.
Where: PDF page 62 (printed page 59), Certified Specifications
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
12 kW
Battery voltage
40 to 60 V
Solar input
Not statedMPPT trackers 2MPPT range 125 to 450 V
AC output
120/240 V split phase; 120/208 V three phase; 50/60 Hz
Warranty
Not stated
Size
Unknown750*440*240mmWeight 42 kg / 93 lb

Evidence score

Research pending0% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • PowMr POW-SunSmart LVM8K, LVM10K and LVM12K user manual V1.1 (PDF, English)Official · PowMr · Official user manual · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-13.

    Location: 9 Parameter Table, PDF pages 61 and 62 (rendered and read)

    Retrieved Oct 12, 2026

    The English user manual PowMr's site menu links for the POW-SunSmart LVM12K, served from its Shopify file store and captured on October 13, 2026. Its parameter table (PDF pages 61 and 62, printed pages 58 and 59) has one column for each of the LVM8K, LVM10K and LVM12K; cells spanning all three columns print one value for all three and were read from the rendered pages. The file name gives version V1.1.0929; no date is printed. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 13.64 MB

    Archived copy, unaltered, kept as a record of what PowMr published. Original address: https://cdn.shopify.com/s/files/1/0746/0415/1079/files/POW-SunSmart_LVM12K_User_Manual_V1.1.0929.pdf?v=1759130253. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    72

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 9cb10d32d374909d73ac8e51b5eb307fba6b2eb75010c62cb477cfc6ff83910b

    Open
  • Other documents

  • PowMr 12KW 48Vdc Hybrid Inverter 110V/240V/208Vac Split Phase Supports 6 Units in Parallel (POW-SunSmart LVM12K) product page (October 13, 2026 capture)Official · PowMr · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-13.

    Location: Overview; Specifications

    Retrieved Oct 12, 2026

    PowMr's own store page at powmr.com, captured on October 13, 2026; the content is whatever the address served on that date. Only the page's own description and its single-model Specifications block are read; the page's product comparison table is not used. The page prints no market or region and carries no revision date. Manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

PowMr POW-SunSmart LVM8K, LVM10K and LVM12K user manual V1.1 (PDF, English)

Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 13.64 MB

Archived copy, unaltered, kept as a record of what PowMr published. Original address: https://cdn.shopify.com/s/files/1/0746/0415/1079/files/POW-SunSmart_LVM12K_User_Manual_V1.1.0929.pdf?v=1759130253. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
72

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 9cb10d32d374909d73ac8e51b5eb307fba6b2eb75010c62cb477cfc6ff83910b

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
POW-SunSmart LVM12K

Manufacturer SKU POW-SunSmart LVM12K

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 0
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Listing stated, none checked
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. PowMr storefront product listing, products.json (October 13, 2026 capture) (PowMr · manufacturer · observed Oct 12, 2026)
  2. PowMr POW-SunSmart LVM8K, LVM10K and LVM12K user manual V1.1 (PDF, English) (PowMr · manufacturer · observed Oct 12, 2026)
  3. PowMr 12KW 48Vdc Hybrid Inverter 110V/240V/208Vac Split Phase Supports 6 Units in Parallel (POW-SunSmart LVM12K) product page (October 13, 2026 capture) (PowMr · manufacturer · observed Oct 12, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details