About brandPhocos AG of Ulm, Germany, makes off-grid and hybrid solar equipment, including the Any-Grid PSW-H hybrid inverter chargers and PSW-B battery inverter chargers and MPPT charge controllers listed on its website. Its PSW-H manual says the inverters are made in China in an ISO 9001 and ISO 14001 certified facility.
SKU detail
locator: Datasheet Technical Data header; manual specification headers; product page certifications list
conditions: Model number as printed on the PSW-H datasheet, in the User and Installation Manual (whose cover prints it as "PSW-H-6.5kW-120/48V") and on the product page.
Printed as "18.2 kg / 40 lbs". Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.4 Net Weight row; datasheet Weight row
Printed as "2" (one manual cell spanning the two 48 V 120 Vac models) and "x 2 MPPTs" on the datasheet. Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.3 Number of Independent MPPTs row; datasheet PV rows
Printed as "120 Vac ± 5% (programmable, 110 ~ 127 Vac)" for the 120 Vac models in the manual; the datasheet prints "110 ~ 127 Vac ± 5% (adjustable)" in the PSW-H-6.5KW-120/48V column.
Where: Manual 12.2 AC Output Voltage Regulation row, 120 Vac models; datasheet AC Output Voltage row
Printed as "120 Adc" maximum battery charging current from AC in a manual column headed "PSW-H-6.5KW-120/48V PSW-H-8KW-230/48V"; the datasheet prints 120 Adc for PV, AC and total charge current in a cell spanning those two models. Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.3 Max. Battery Charging Current row; datasheet Max. Total Charge Current row
W 433 × H 584 × D 148 mm / W 17 × H 23 × D 5.83 in convertedCheck note
The datasheet labels the same figures in a different axis order. Phocos's PSW-H datasheet (version 2024-03-25) prints these dimensions as "584 (651) x 433 x 148 mm / 23 (25.6) x 17 x 5.8 in (with extension box)" under the heading "Dimensions (WxHxD)", while the User and Installation Manual (version 20230515) prints the same numbers under "Housing Dimensions (H x W x D)". The manual's axis order is recorded.
Printed as "584 (651) x 433 x 148 mm / 23 (25.6) x 17 x 5.8 in (with extension box)" (H x W x D) in the manual; the height is 651 mm with the included extension box. Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Peak efficiency from battery, printed as "> 92%" in the manual (one cell spanning the PSW-H-5KW-120/48V and PSW-H-6.5KW-120/48V columns) and "> 92 % peak" on the datasheet (one cell spanning the PSW-H-6.5KW-120/48V and PSW-H-8KW-230/48V columns); the datasheet prints "> 96 % peak" from PV. Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Printed as "90 Vdc ~ 230 Vdc" in the manual and "90 ~ 230 Vdc x 2 MPPTs" on the datasheet. Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.3 Solar Array MPP Voltage Range row; datasheet PV Panel MPP Voltage row
10 kW*Converted: 5000 Wp per MPPT x 2 MPPTs = 10000 Wp; 10000 Wp / 1000 W per kW = 10 kW
Printed as "5000 Wp per MPPT" in the manual and "5000 Wp x 2 MPPTs" on the datasheet; recorded as the two-input total. Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.3 Max. Solar Array Power row; datasheet Max. PV Array Power row
Sources
Converted: 5000 Wp per MPPT x 2 MPPTs = 10000 Wp; 10000 Wp / 1000 W per kW = 10 kW
8 kW*Converted: 4000 W per MPPT x 2 MPPTs = 8000 W; 8000 W / 1000 W per kW = 8 kW
Printed as "4000 W per MPPT" in the manual and "4000 W x 2 MPPTs" on the datasheet (one cell spanning PSW-H-6.5KW-120/48V and PSW-H-8KW-230/48V); recorded as the two-input total. Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.3 Max. Usable Solar Power row; datasheet Max. Usable PV Power row
Sources
Converted: 4000 W per MPPT x 2 MPPTs = 8000 W; 8000 W / 1000 W per kW = 8 kW
Printed as "120 Adc". Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Printed as "120 Adc". Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Printed as "Output Waveform Pure Sine Wave" in the maker's document "PSW-H (3 kW/5 kW/6.5 kW/8 kW) Any-Grid Hybrid Inverter Charger datasheet, version 2024-03-25 (Phocos)".
Printed as "22 Adc per MPPT, 36 Adc total". Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.3 Max. Usable Solar Input Current row; datasheet Max. Usable PV Current row
Printed as "250 Vdc, OVC II" in the manual and "250 Vdc x 2 MPPTs" on the datasheet, per MPPT input. Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.3 Max. Solar Array Open Circuit Voltage row; datasheet Max. PV Panel Voltage row
Printed as "6500 VA / 6500 W". Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Printed as "48 Vdc". Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.2 Nominal Battery Input Voltage row; datasheet System Voltage row
Printed as "60 Aac" maximum AC input current (one manual cell spanning the PSW-H-5KW-120/48V and PSW-H-6.5KW-120/48V columns; one datasheet cell spanning PSW-H-6.5KW-120/48V and PSW-H-8KW-230/48V); the manual gives the grid-mode maximum AC output power as 60 Aac times the AC input voltage, for example 7,200 W at 120 Vac. Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.1 Maximum AC Input Current row; datasheet Max. AC Input Current row
Printed as "< 58 W" with AC output on and PV and AC input unavailable ("< 58 W on" on the datasheet). Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Printed as "Up to 9 units in parallel, 3-phase or split-phase" in the PSW-H-6.5KW-120/48V column (the third of four Extensibility cells, read from the rendered datasheet page 3).
UL1741; CSA C22.2 No. 107.1-16; FCC Class A (applies to the display unit)
Manufacturer claims recorded as printed: the manual says "The PSW-H-6.5KW-120/48V model is UL1741 and CSA22.2 No. 107 and FCC Class A (applies to the display unit) compliant", and the datasheet prints "UL1741, CSA C22.2 No. 107.1-16, FCC Class A, RoHS compliant" for this model. The product page links a "PSW-H-6.5KW-120/48V UL1741 & CSA C22.2 No. 107 Certificate", which was not read.
Where: Manual safety section and 12.4 Certifications row; datasheet Certificates row; product page certifications list
Printed as "6500 VA / 6500 W". Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
Where: Manual 12.2 Nominal AC Output Power row; datasheet Rated AC Output Power row
-10 ~ 40 °C for UL compatibility; up to 50 °C without UL compatibility Check note
The datasheet prints a single wider range. Phocos's PSW-H datasheet (version 2024-03-25) prints "Ambient Temperature -10 to +50 °C / +14 to +122 °F" for every model, without the UL condition the User and Installation Manual (version 20230515) states for the 120 Vac models. The manual's wording is recorded.
The manual prints "-10 ~ 40 °C, 14 ~ 104 °F for UL compatibility; up to 50 °C, 122 °F without UL compatibility" in a cell spanning the three 120 Vac models (read from the rendered manual page 56); the 230 Vac models print -10 ~ 50 °C.
Where: Manual 12.4 Operating Temperature Range row, 120 Vac models; datasheet Ambient Temperature row
37.43 L* (Calculated from published dimensions)W: 433 × H: 584 × D: 148 mm / W: 17 × H: 23 × D: 5.83 inWeight18.2 kg / 40.1 lb
Evidence score
4/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term3 years3.6 / 30.0
3 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
The manual says Phocos warrants the product "against defects in materials and workmanship for a period of 3 years from the date of purchase" and will repair or replace a defective unit returned postage paid to Phocos; the datasheet prints "Warranty 3 years".
Printed as "< 58 W" with AC output on and PV and AC input unavailable ("< 58 W on" on the datasheet). Read from the PSW-H-6.5KW-120/48V column (the fifth of six in the manual's tables, the fourth of five on the datasheet); cells spanning several columns were read from the rendered pages.
A value is on file but is not counted: it carries a warning or is not confirmed.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
3 years
The manual says Phocos warrants the product "against defects in materials and workmanship for a period of 3 years from the date of purchase" and will repair or replace a defective unit returned postage paid to Phocos; the datasheet prints "Warranty 3 years".
Location: Section 12.0 Specifications and section 13.0 Warranty
Retrieved Oct 2, 2026
Phocos's User and Installation Manual for the six Any-Grid PSW-H models, linked from the PSW-H product page. Its specification tables (section 12) have one column per model, with some cells spanning several models; those were read from the rendered pages.
Archived copies
Archived copy of a document published by Phocos AG. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Phocos's English datasheet for five PSW-H models, linked from the PSW-H product page. Its Technical Data table has one column per model with merged cells; those were read from the rendered page 3. It does not list the PSW-H-5KW-120/48V.
Archived copies
Archived copy of a document published by Phocos AG. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: Downloads and Declarations & Certifications sections
Retrieved Oct 2, 2026
Phocos's product page for the PSW-H series, captured on October 2, 2026. It links the datasheet, the manual and a PSW-H-6.5KW-120/48V UL1741 and CSA certificate; it prints no per-model figures for the 120 Vac models.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Any-Grid PSW-H User and Installation Manual, English, version 20230515 (Phocos)
Archived copy of a document published by Phocos AG. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Phocos AG. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].