Key specs

Max PV voltage60 V
Weight1.5 kg / 3.3 lb converted
Weighted efficiency95.5 %
Max PV input current14 A
Max PV short circuit18 A
Continuous output0.25 kW

All specifications

Identity

BrandNorthern Electric Power · Website
ModelNC0144-US-BQ
MarketUS
Manufacturer SKUNC0144-US-BQ
About brandNorthern Electric Power (NEP) makes solar microinverters, including the BDM series, along with gateways, rapid shutdown devices and connection accessories for them.
SKU detail
locator: Datasheet heading
conditions: NEP prints "(NC0144-US-BQ, NC0144-L-US-BQ)" under the heading "BDM-300 CEC Listing as Utility Interactive Inverter". NEP does not say how NC0144-US-BQ differs from NC0144-L-US-BQ.
Sources: [1]
FieldValueConditionsSource
GroundingThrough the trunk cable grounding wire to the junction box ground connector, or through the racking
Printed as "The grounding wire is connected through the trunk cable" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 4.8 Ground the System.
Where: PDF page 13, 4.8 Ground the System
[2]
Weight1.5 kg / 3.3 lb converted
The Weight row of the BDM-300 data sheet prints "3.3 lbs. (1.5 kg)" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Weight row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source.
Where: PDF page 22, 8.1 BDM-300 data sheet, Weight row
[2] [1]
MPPT count1
The datasheet prints single-input figures (Recommended Max PV Power 400 W, Max DC Input Current 14 A) with no multiplier; NEP does not print an MPPT count row.
Where: Specifications, Input (DC)
[1]
DimensionsW 180 × H 186 × D 25 mm / W 7.09 × H 7.32 × D 0.98 in converted
The Dimension (W-H-D) row of the BDM-300 data sheet prints "7.09" x7.32" x 0.98" (180x186x25 mm)" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Dimension (W-H-D) row; read from rendered page 22.
Where: PDF page 22, 8.1 BDM-300 data sheet, Dimension (W-H-D) row
[2]
CommunicationsPowerline communicationsPrinted as "Powerline Communications".
Where: Specifications, Communications
[1]
MPPT voltage22 to 55 V
The MPPT Tracking Range (Vdc) row of the BDM-300 data sheet prints "22-55" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, MPPT Tracking Range (Vdc) row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source.
Where: PDF page 22, 8.1 BDM-300 data sheet, MPPT Tracking Range (Vdc) row
[2] [1]
Enclosure ratingNEMA-6 / IP-66 / IP-67
The Protection Degree row of the BDM-300 data sheet prints "NEMA-6 / IP-66 / IP-67" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Protection Degree row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source.
Where: PDF page 22, 8.1 BDM-300 data sheet, Protection Degree row
[2] [1]
Max PV voltage60 V
The Max DC Open Circuit Voltage (Vdc) row of the BDM-300 data sheet prints "60" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Max DC Open Circuit Voltage (Vdc) row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source.
Where: PDF page 22, 8.1 BDM-300 data sheet, Max DC Open Circuit Voltage (Vdc) row
[2] [1]
AC output breaker20A maximum breaker per AC branch circuit (12AWG trunk cable)
Printed as "EACH BDM-300/400 AC BRANCH CIRCUIT MUST BE SOURCED FROM A DEDICATED BRANCH CIRCUIT PROTECTED BY A 20A MAXIMUM BREAKER" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 4.7 Connect the BDM-300/400 Wiring Harnesses, branch circuit warning. The data sheet gives the maximum number of units per 20A branch as 15 at 240 V, 13 at 208 V and 14 at 230 V (read from rendered page 22).
Where: PDF page 12, 4.7 Connect the BDM-300/400 Wiring Harnesses, branch circuit warning
[2]
Certification claimsUL 1741; CSA C22.2, NO. 107.1; IEC/EN 62109-1; IEC/EN 62109-2; IEEE 1547; VDE-AR-N 4105*; VDE V 0126-1-1/A1; G83/2; CEI 21; AS 4777.2; AS 4777.3; EN50438; ABNT NBR 16149/16150
Certifications line as printed by NEP for both BDM-300 part numbers. Manufacturer claim; no issuer directory was checked.
Where: Certifications line
[1]
Continuous output0.25 kW
The Rated AC Output Power (Wp) row of the BDM-300 data sheet prints "250" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Rated AC Output Power (Wp) row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source.
Where: PDF page 22, 8.1 BDM-300 data sheet, Rated AC Output Power (Wp) row
[2] [1]
Max PV input current14 A
Printed as 14 A for the single input; Isc PV (absolute maximum) 18 A.
Where: Specifications, Input (DC), Max DC Input Current
[1]
Max PV short circuit18 A
The Isc PV (absolute maximum) (Adc) row of the BDM-300 data sheet prints "18" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Isc PV (absolute maximum) (Adc) row; read from rendered page 22.
Where: PDF page 22, 8.1 BDM-300 data sheet, Isc PV (absolute maximum) (Adc) row
[2]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
The Operating Temperature row of the BDM-300 data sheet prints "-40°F to +185°F (-40°C to +85°C)" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Operating Temperature row; read from rendered page 22. The Ambient Temperature row reads "-40°F to +149°F (-40°C to +65°C)". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source.
Where: PDF page 22, 8.1 BDM-300 data sheet, Operating Temperature row
[2] [1]
Weighted efficiency95.5 %
The Weighted Averaged Efficiency (CEC) row of the BDM-300 data sheet prints "95.50%" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Weighted Averaged Efficiency (CEC) row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source.
Where: PDF page 22, 8.1 BDM-300 data sheet, Weighted Averaged Efficiency (CEC) row
[2] [1]
AC voltage configuration240 V single-phase (211-264 V) or 208 V three-phase (183-228 V)
Printed as 240 Vac and "3φ: 208 Vac", allowable 211-264 Vac and "3φ: 183-228 Vac"; nominal frequency 60 Hz.
Where: Specifications, Output (AC), Nominal and Allowable Power Grid Voltage
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
0.25 kW
Battery voltage
Not stated
Solar input
Not statedMPPT trackers 1MPPT range 22 to 55 V
AC output
Not stated
Warranty
Not stated
Size
0.84 L* (Calculated from published dimensions)W: 180 × H: 186 × D: 25 mm / W: 7.09 × H: 7.32 × D: 0.98 inWeight 1.5 kg / 3.3 lb

Evidence score

10/100Missing details45% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741 · CSA C22.2, NO. 107.1 +1Claimed10.2 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[1]

Research pending, 0 points: Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
CSA C22.2, NO. 107.1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
NC0144-US-BQ; NC0144-L-US-BQ
Limitations
Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("CSA C22.2, NO. 107.1"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 24, 2026
Source
[1]
IEEE 1547manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
NC0144-US-BQ; NC0144-L-US-BQ
Limitations
Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("IEEE 1547"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 24, 2026
Source
[1]
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
NC0144-US-BQ; NC0144-L-US-BQ
Limitations
Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("UL 1741"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 24, 2026
Source
[1]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • NEP Installation and Operation Manual BDM-300/400 Microinverter (v4, modified 05/18/2023)Official · Northern Electric Power Technology Inc. · Official installation manual · May 2023 · PDF
    Source details
    Revision
    v4 (Modified 05/18/2023)
    Revision date
    May 2023

    Archived copy captured on 2026-10-01.

    Location: PDF page 1, title; PDF page 22, 8.1 BDM-300 data sheet

    Retrieved Oct 1, 2026

    Northern Electric Power's own installation and operation manual for the BDM-300 and BDM-400 microinverters, linked from NEP's BDM 300 product page and captured 1 October 2026 from northernep.com; file version v4, pages marked "Modified 05/18/2023". It names the BDM-300 and carries a BDM-300 data sheet (section 8.1); it does not print the part numbers NC0144-US-BQ or NC0144-L-US-BQ. Manufacturer instructions, not independent tests.

    Archived copies

    Archived copy of a document published by Northern Electric Power Technology Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupv4 (Modified 05/18/2023) · 4.53 MB

    Archived copy, unaltered, kept as a record of what Northern Electric Power Technology Inc. published. Original address: https://northernep.com/wp-content/uploads/2023/05/BDM-300_400_Manual_v4.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    24

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 680188a44e491d5621d5e446a7b4da491bad4559fc0cc4621baea12ccb5f539e

    Open
  • Datasheets

  • NEP BDM-300 Microinverter product datasheet (102623)Official · Northern Electric Power · Official datasheet · PDF
    Certificate & compliance claims (3)
    UL 1741Manufacturer claim · equipment listingClaimedListed when checked

    Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("UL 1741"). No certificate number or issuer is printed beside it, and no issuer directory was checked.

    Manufacturer document

    Official datasheet: NEP BDM-300 Microinverter product datasheet (102623)
    CSA C22.2, NO. 107.1Manufacturer claim · equipment listingClaimedListed when checked

    Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("CSA C22.2, NO. 107.1"). No certificate number or issuer is printed beside it, and no issuer directory was checked.

    Manufacturer document

    Official datasheet: NEP BDM-300 Microinverter product datasheet (102623)
    IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked

    Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("IEEE 1547"). No certificate number or issuer is printed beside it, and no issuer directory was checked.

    Manufacturer document

    Official datasheet: NEP BDM-300 Microinverter product datasheet (102623)
    Source details
    Revision
    102623
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.

    Location: Heading; Specifications table

    Retrieved Sep 23, 2026

    Northern Electric Power's own one-page BDM-300 datasheet, linked from its BDM 300 product page and captured on September 24, 2026. Its heading lists the part numbers NC0144-US-BQ and NC0144-L-US-BQ together under "BDM-300 CEC Listing as Utility Interactive Inverter" and does not say how the two differ. Its page footer reads "BDM-600X-102623". Where a row prints two values, the second is marked 3φ (208 Vac). The certification list is a manufacturer claim; no issuer directory or CEC list was read.

    Archived copies

    Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup102623 · 0.83 MB

    Archived copy, unaltered, kept as a record of what Northern Electric Power published. Original address: https://northernep.com/wp-content/uploads/2023/10/BDM-300-Datasheet-102623.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    1

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: e2eb56f31efdb152329405203679a3aad3050467166a206ab2a86656a08f2326

    Open
  • Other documents

  • NEP BDM 300 Microinverter product page (captured September 24, 2026)Official · Northern Electric Power · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.

    Location: Downloads block; product photograph

    Retrieved Sep 23, 2026

    Northern Electric Power's own BDM 300 product page, captured on September 24, 2026. Cited for identity, for its link to the BDM-300 datasheet and for the product photograph. Its text says "high continuous output power of up to 300w AC", while its own table and the datasheet print 300 W as peak and 250 W as rated or maximum continuous output; the page wording is not used for any figure.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

NEP BDM-300 Microinverter product datasheet (102623)

Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup102623 · 0.83 MB

Archived copy, unaltered, kept as a record of what Northern Electric Power published. Original address: https://northernep.com/wp-content/uploads/2023/10/BDM-300-Datasheet-102623.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
1

Embedded dates are file metadata, not independent proof of publication.

SHA-256: e2eb56f31efdb152329405203679a3aad3050467166a206ab2a86656a08f2326

NEP Installation and Operation Manual BDM-300/400 Microinverter (v4, modified 05/18/2023)

Archived copy of a document published by Northern Electric Power Technology Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupv4 (Modified 05/18/2023) · 4.53 MB

Archived copy, unaltered, kept as a record of what Northern Electric Power Technology Inc. published. Original address: https://northernep.com/wp-content/uploads/2023/05/BDM-300_400_Manual_v4.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
24

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 680188a44e491d5621d5e446a7b4da491bad4559fc0cc4621baea12ccb5f539e

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
NC0144-US-BQ
Published model / SKU
BDM-300

NEP lists NC0144-US-BQ under the BDM-300 heading of its BDM-300 datasheet (102623).

[1]

Manufacturer SKU NC0144-US-BQ · US market

  1. Observed Sep 24, 2026

    UL 1741: claimed

    Product / system scope unresolved. Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("UL 1741"). No certificate number or issuer is printed beside it, and no issuer directory was checked.

    [1]

  2. Observed Sep 24, 2026

    CSA C22.2, NO. 107.1: claimed

    Product / system scope unresolved. Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("CSA C22.2, NO. 107.1"). No certificate number or issuer is printed beside it, and no issuer directory was checked.

    [1]

  3. Observed Sep 24, 2026

    IEEE 1547: claimed

    Product / system scope unresolved. Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("IEEE 1547"). No certificate number or issuer is printed beside it, and no issuer directory was checked.

    [1]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 45
basis: Unknown
missing:
Warranty term needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 22.75
unit: Unknown
shown: UL 1741 · CSA C22.2, NO. 107.1 +1
shown detail: Claimed
state: claimed
points: 10.2
ceiling: 45
weight: 45
share: 22.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [1]
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. NEP BDM-300 Microinverter product datasheet (102623) (Northern Electric Power · manufacturer · 102623 · observed Sep 23, 2026)
  2. NEP Installation and Operation Manual BDM-300/400 Microinverter (v4, modified 05/18/2023) (Northern Electric Power Technology Inc. · manufacturer · v4 (Modified 05/18/2023) · observed Oct 1, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details