Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Northern Electric Power's image for the BDM 300 Microinverter (one image for both NC0144 part numbers), shown on the NC0144-L-US-BQ page; not a photo specific to this exact modelNEP BDM-300 Microinverter (NC0144-L-US-BQ)
Key specs
All specifications
No spec by that name.
Show all 21 specifications
Identity
SKU detail
| Field | Value | Conditions | Source |
|---|---|---|---|
| Grounding | Through the trunk cable grounding wire to the junction box ground connector, or through the racking | Printed as "The grounding wire is connected through the trunk cable" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 4.8 Ground the System. Where: PDF page 13, 4.8 Ground the System | [2] |
| Weight | 1.5 kg / 3.3 lb converted | The Weight row of the BDM-300 data sheet prints "3.3 lbs. (1.5 kg)" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Weight row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source. Where: PDF page 22, 8.1 BDM-300 data sheet, Weight row | [2] [1] |
| MPPT count | 1 | The datasheet prints single-input figures (Recommended Max PV Power 400 W, Max DC Input Current 14 A) with no multiplier; NEP does not print an MPPT count row. Where: Specifications, Input (DC) | [1] |
| Dimensions | W 180 × H 186 × D 25 mm / W 7.09 × H 7.32 × D 0.98 in converted | The Dimension (W-H-D) row of the BDM-300 data sheet prints "7.09" x7.32" x 0.98" (180x186x25 mm)" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Dimension (W-H-D) row; read from rendered page 22. Where: PDF page 22, 8.1 BDM-300 data sheet, Dimension (W-H-D) row | [2] |
| Communications | Powerline communications | Printed as "Powerline Communications". Where: Specifications, Communications | [1] |
| MPPT voltage | 22 to 55 V | The MPPT Tracking Range (Vdc) row of the BDM-300 data sheet prints "22-55" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, MPPT Tracking Range (Vdc) row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source. Where: PDF page 22, 8.1 BDM-300 data sheet, MPPT Tracking Range (Vdc) row | [2] [1] |
| Enclosure rating | NEMA-6 / IP-66 / IP-67 | The Protection Degree row of the BDM-300 data sheet prints "NEMA-6 / IP-66 / IP-67" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Protection Degree row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source. Where: PDF page 22, 8.1 BDM-300 data sheet, Protection Degree row | [2] [1] |
| Max PV voltage | 60 V | The Max DC Open Circuit Voltage (Vdc) row of the BDM-300 data sheet prints "60" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Max DC Open Circuit Voltage (Vdc) row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source. Where: PDF page 22, 8.1 BDM-300 data sheet, Max DC Open Circuit Voltage (Vdc) row | [2] [1] |
| AC output breaker | 20A maximum breaker per AC branch circuit (12AWG trunk cable) | Printed as "EACH BDM-300/400 AC BRANCH CIRCUIT MUST BE SOURCED FROM A DEDICATED BRANCH CIRCUIT PROTECTED BY A 20A MAXIMUM BREAKER" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 4.7 Connect the BDM-300/400 Wiring Harnesses, branch circuit warning. The data sheet gives the maximum number of units per 20A branch as 15 at 240 V, 13 at 208 V and 14 at 230 V (read from rendered page 22). Where: PDF page 12, 4.7 Connect the BDM-300/400 Wiring Harnesses, branch circuit warning | [2] |
| Certification claims | UL 1741; CSA C22.2, NO. 107.1; IEC/EN 62109-1; IEC/EN 62109-2; IEEE 1547; VDE-AR-N 4105*; VDE V 0126-1-1/A1; G83/2; CEI 21; AS 4777.2; AS 4777.3; EN50438; ABNT NBR 16149/16150 | Certifications line as printed by NEP for both BDM-300 part numbers. Manufacturer claim; no issuer directory was checked. Where: Certifications line | [1] |
| Continuous output | 0.25 kW | The Rated AC Output Power (Wp) row of the BDM-300 data sheet prints "250" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Rated AC Output Power (Wp) row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source. Where: PDF page 22, 8.1 BDM-300 data sheet, Rated AC Output Power (Wp) row | [2] [1] |
| Max PV input current | 14 A | Printed as 14 A for the single input; Isc PV (absolute maximum) 18 A. Where: Specifications, Input (DC), Max DC Input Current | [1] |
| Max PV short circuit | 18 A | The Isc PV (absolute maximum) (Adc) row of the BDM-300 data sheet prints "18" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Isc PV (absolute maximum) (Adc) row; read from rendered page 22. Where: PDF page 22, 8.1 BDM-300 data sheet, Isc PV (absolute maximum) (Adc) row | [2] |
| Operating temperature | -40 to 85 °C / -40 to 185 °F converted | The Operating Temperature row of the BDM-300 data sheet prints "-40°F to +185°F (-40°C to +85°C)" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Operating Temperature row; read from rendered page 22. The Ambient Temperature row reads "-40°F to +149°F (-40°C to +65°C)". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source. Where: PDF page 22, 8.1 BDM-300 data sheet, Operating Temperature row | [2] [1] |
| Weighted efficiency | 95.5 % | The Weighted Averaged Efficiency (CEC) row of the BDM-300 data sheet prints "95.50%" in NEP's BDM-300/400 installation and operation manual (v4, modified 05/18/2023), 8.1 BDM-300 data sheet, Weighted Averaged Efficiency (CEC) row; read from rendered page 22. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Northern Electric Power (northernep.com), which stays listed as an additional source. Where: PDF page 22, 8.1 BDM-300 data sheet, Weighted Averaged Efficiency (CEC) row | [2] [1] |
| AC voltage configuration | 240 V single-phase (211-264 V) or 208 V three-phase (183-228 V) | Printed as 240 Vac and "3φ: 208 Vac", allowable 211-264 Vac and "3φ: 183-228 Vac"; nominal frequency 60 Hz. Where: Specifications, Output (AC), Nominal and Allowable Power Grid Voltage | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Continuous output
- 0.25 kW
- Battery voltage
- Not stated
- Solar input
- Not statedMPPT trackers 1MPPT range 22 to 55 V
- AC output
- Not stated
- Warranty
- Not stated
- Size
- 0.84 L* (Calculated from published dimensions)W: 180 × H: 186 × D: 25 mm / W: 7.09 × H: 7.32 × D: 0.98 inWeight 1.5 kg / 3.3 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Research pending, 0 points: Warranty term, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
How it worksCertificates
CSA C22.2, NO. 107.1manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- NC0144-US-BQ; NC0144-L-US-BQ
- Limitations
- Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("CSA C22.2, NO. 107.1"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 24, 2026
- Source
- [1]
IEEE 1547manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- NC0144-US-BQ; NC0144-L-US-BQ
- Limitations
- Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("IEEE 1547"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 24, 2026
- Source
- [1]
UL 1741manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- NC0144-US-BQ; NC0144-L-US-BQ
- Limitations
- Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("UL 1741"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 24, 2026
- Source
- [1]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- NEP Installation and Operation Manual BDM-300/400 Microinverter (v4, modified 05/18/2023)Open
Source details
Archived copy captured on 2026-10-01.
Location: PDF page 1, title; PDF page 22, 8.1 BDM-300 data sheet
Retrieved Oct 1, 2026
Northern Electric Power's own installation and operation manual for the BDM-300 and BDM-400 microinverters, linked from NEP's BDM 300 product page and captured 1 October 2026 from northernep.com; file version v4, pages marked "Modified 05/18/2023". It names the BDM-300 and carries a BDM-300 data sheet (section 8.1); it does not print the part numbers NC0144-US-BQ or NC0144-L-US-BQ. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Northern Electric Power Technology Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupv4 (Modified 05/18/2023) · 4.53 MBArchived copy, unaltered, kept as a record of what Northern Electric Power Technology Inc. published. Original address: https://northernep.com/wp-content/uploads/2023/05/BDM-300_400_Manual_v4.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 680188a44e491d5621d5e446a7b4da491bad4559fc0cc4621baea12ccb5f539e
Datasheets
- NEP BDM-300 Microinverter product datasheet (102623)Open
Certificate & compliance claims (3)
UL 1741Manufacturer claim · equipment listingClaimedListed when checked
Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("UL 1741"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: NEP BDM-300 Microinverter product datasheet (102623)CSA C22.2, NO. 107.1Manufacturer claim · equipment listingClaimedListed when checked
Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("CSA C22.2, NO. 107.1"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: NEP BDM-300 Microinverter product datasheet (102623)IEEE 1547Manufacturer claim · equipment listingClaimedListed when checked
Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("IEEE 1547"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: NEP BDM-300 Microinverter product datasheet (102623)Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Heading; Specifications table
Retrieved Sep 23, 2026
Northern Electric Power's own one-page BDM-300 datasheet, linked from its BDM 300 product page and captured on September 24, 2026. Its heading lists the part numbers NC0144-US-BQ and NC0144-L-US-BQ together under "BDM-300 CEC Listing as Utility Interactive Inverter" and does not say how the two differ. Its page footer reads "BDM-600X-102623". Where a row prints two values, the second is marked 3φ (208 Vac). The certification list is a manufacturer claim; no issuer directory or CEC list was read.
Archived copies
Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backup102623 · 0.83 MBArchived copy, unaltered, kept as a record of what Northern Electric Power published. Original address: https://northernep.com/wp-content/uploads/2023/10/BDM-300-Datasheet-102623.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: e2eb56f31efdb152329405203679a3aad3050467166a206ab2a86656a08f2326
Other documents
- NEP BDM 300 Microinverter product page (captured September 24, 2026)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Downloads block; product photograph
Retrieved Sep 23, 2026
Northern Electric Power's own BDM 300 product page, captured on September 24, 2026. Cited for identity, for its link to the BDM-300 datasheet and for the product photograph. Its text says "high continuous output power of up to 300w AC", while its own table and the datasheet print 300 W as peak and 250 W as rated or maximum continuous output; the page wording is not used for any figure.
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
NEP BDM-300 Microinverter product datasheet (102623)
Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Northern Electric Power published. Original address: https://northernep.com/wp-content/uploads/2023/10/BDM-300-Datasheet-102623.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: e2eb56f31efdb152329405203679a3aad3050467166a206ab2a86656a08f2326
NEP Installation and Operation Manual BDM-300/400 Microinverter (v4, modified 05/18/2023)
Archived copy of a document published by Northern Electric Power Technology Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Northern Electric Power Technology Inc. published. Original address: https://northernep.com/wp-content/uploads/2023/05/BDM-300_400_Manual_v4.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 680188a44e491d5621d5e446a7b4da491bad4559fc0cc4621baea12ccb5f539e
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- NC0144-L-US-BQ
- Published model / SKU
- BDM-300
NEP lists NC0144-L-US-BQ under the BDM-300 heading of its BDM-300 datasheet (102623).
[1]
Manufacturer SKU NC0144-L-US-BQ · US market
Observed Sep 24, 2026
UL 1741: claimed
Product / system scope unresolved. Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("UL 1741"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
Observed Sep 24, 2026
CSA C22.2, NO. 107.1: claimed
Product / system scope unresolved. Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("CSA C22.2, NO. 107.1"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
Observed Sep 24, 2026
IEEE 1547: claimed
Product / system scope unresolved. Manufacturer claim in the Certifications line of NEP's BDM-300 datasheet (102623), which covers both NC0144-US-BQ and NC0144-L-US-BQ, recorded exactly as printed ("IEEE 1547"). No certificate number or issuer is printed beside it, and no issuer directory was checked.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 45 basis: Unknown missing: Warranty term needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 22.75 unit: Unknown shown: UL 1741 · CSA C22.2, NO. 107.1 +1 shown detail: Claimed state: claimed points: 10.2 ceiling: 45 weight: 45 share: 22.8 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [1] key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- NEP BDM-300 Microinverter product datasheet (102623) (Northern Electric Power · manufacturer · 102623 · observed Sep 23, 2026)
- NEP Installation and Operation Manual BDM-300/400 Microinverter (v4, modified 05/18/2023) (Northern Electric Power Technology Inc. · manufacturer · v4 (Modified 05/18/2023) · observed Oct 1, 2026)
Sign in to report an error on this page
Similar products
All with a priceEnphase IQ8+ Microinverter IQ8PLUS-72-M-US
Enphase IQ8M Microinverter IQ8M-72-2-US
Enphase IQ8A Microinverter IQ8A-72-2-US
Duracell Power Center D350-M1A Microinverter
* Missing details