Key specs

Units
SKU
BDM-600
Official document
Sources

NEP prints the model as "BDM-600 (BDM-300X2)" on its technical sheet and as "BDM 600" on its product page. No separate ordering code for the BDM-600 is printed; the NC0142 part numbers NEP prints belong to the BDM-600X.

Official document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Technical sheet heading

Documented

Weight
2.9 kg6.4 lb converted
Official document
Sources

Printed as 6.4 Ibs. (2.9 kg) on the technical sheet; the product page prints 6.4 Ibs for both columns.

Official document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier documentOfficial product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier document

Location: Technical sheet, Weight; product page, Weight

Documented

Dimensions
1.83 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 277 × H: 132 × D: 50 mmW: 10.9 × H: 5.2 × D: 2 in convertedOfficial document
Sources

Printed as 10.91”x5.20”x1.97”(277x132x50 mm), width by height by depth; the product page prints the same inch figures.

Official document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Technical sheet, Dimension (W-H-D)

Calculated

Communications
Power line communication
Official product page
Sources

Printed as "Power Line"; monitoring runs through NEP's BDG-256 gateway.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier documentOfficial document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Product Characteristics table, BDM 600 column (first of two), Comunications

Documented

MPPT voltage range
22 to 55 V
Official product page
Sources

Printed as 22-55 Vdc on both documents.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier documentOfficial document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Product Characteristics table, BDM 600 column (first of two), MPPT Tracking Range (Vdc)

Documented

Enclosure
NEMA-6 / IP-66 / IP-67
Official product page
Sources

Printed identically on both documents.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier documentOfficial document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Product Characteristics table, BDM 600 column (first of two), Protection Degree

Documented

Maximum PV voltage
60 V
Official product page
Sources

Printed as 60 Vdc on the page (BDM 600 column) and as Max DC Open Circuit Voltage 60 Vdc on the technical sheet.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier documentOfficial document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Product Characteristics table, BDM 600 column (first of two), Recommended Max DC Open Circuit Voltage (Vdc)

Documented

Certifications (as printed)
UL 1741; CSA C22.2 No. 107.1; IEC/EN 62109-1; IEC/EN 62109-2; IEEE 1547; VDE-AR-N 4105; VDE V 0126-1-1/A1; G83/2; CEI 021; AS 4777.2 & AS 4777.3; EN50438
Official product page
Sources

Lists as printed on the product page for the BDM 600 column. Manufacturer claim; NEP says to refer to the label for the detailed grid code compliance. No issuer directory was checked.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier document

Location: Product Characteristics table, BDM 600 column (first of two), Product Safety Compliance and Grid Code Compliance

Documented

Continuous output
0.5 kW
Official product page
Sources

NEP prints "Rated AC Output Power (Wp) 500" in the BDM 600 column of its product page and on its BDM-600 technical sheet; recorded as 0.5 kW. On NEP's BDM-300 datasheet the same kind of figure is labeled maximum continuous output power. Peak output is not recorded because the two documents disagree (550 Wp on the page, 580 on the technical sheet).

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier documentOfficial document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Product Characteristics table, BDM 600 column (first of two), Rated AC Output Power (Wp); technical sheet Rated AC Output Power

Documented

All specs12
Continuous output
0.5 kW
Official product page
Sources

NEP prints "Rated AC Output Power (Wp) 500" in the BDM 600 column of its product page and on its BDM-600 technical sheet; recorded as 0.5 kW. On NEP's BDM-300 datasheet the same kind of figure is labeled maximum continuous output power. Peak output is not recorded because the two documents disagree (550 Wp on the page, 580 on the technical sheet).

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier documentOfficial document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Product Characteristics table, BDM 600 column (first of two), Rated AC Output Power (Wp); technical sheet Rated AC Output Power

Documented

Weighted efficiency
95.5 %
Official product page
Sources

CEC weighted efficiency printed as 95.50% on both documents. Manufacturer claim.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier documentOfficial document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Product Characteristics table, BDM 600 column (first of two), Weighted Averaged Efficiency (CEC)

Documented

AC voltage configuration
240 V (211-264 V), 208 V (183-229 V) or 230 V (configurable)
Official product page
Sources

Printed as nominal 240 / 208 / 230 Vac with allowable ranges 211V-264 / 183V-229 / configurable; nominal frequency 60 / 50 Hz. NEP notes grid parameters are configurable through a BDG-256 or BDG-256P3 gateway.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier documentOfficial document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Location: Product Characteristics table, BDM 600 column (first of two), Nominal and Allowable Power Grid Voltage (Vac)

Documented

Published claims and calculations, not independent test results.

Documents

1 on file
  • WEB
    NEP BDM 600 Microinverter product page (captured September 24, 2026)OfficialNorthern Electric PowerOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Product Characteristics table, BDM 600 column

    Retrieved

    Northern Electric Power's own BDM 600 product page, captured on September 24, 2026. Its Product Characteristics table prints two columns, "BDM 600" first and "BDM 600X" second; only the first column is read for the BDM-600. The page carries no revision or date. The datasheet it links is the BDM-600X datasheet and is not cited for the BDM-600.

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • PDF
    NEP BDM-600 (BDM-300X2) Microinverter technical sheetOfficialNorthern Electric PowerOfficial document
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Location: Page 2 specification table

    Retrieved

    Northern Electric Power's own two-page technical sheet headed "BDM-600 (BDM-300X2) MICROINVERTER", listed as "BDM 600 Microinverter" on its Downloads page and captured on September 24, 2026. It carries no revision or date. It prints "Peak AC Output Power (Wp) 580 (continuous)", which the product page gives for the BDM 600X column, while the product page gives 550 Wp for the BDM 600; the peak output is therefore not recorded. Its compliance lists are manufacturer claims.

    Archived copies

    Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 0.22 MB

    Archived copy, unaltered, kept as a record of what Northern Electric Power published. Original address: https://northernep.com/downloads/technical-sheet/BDM-600-Microinverter.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    2
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 5253f62b251f83d1ec41f81900111ed6b56a8107a1d86006516d73cc1b5e77ef

    Open

Archived documents

NEP BDM-600 (BDM-300X2) Microinverter technical sheet

Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 0.22 MB

Archived copy, unaltered, kept as a record of what Northern Electric Power published. Original address: https://northernep.com/downloads/technical-sheet/BDM-600-Microinverter.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
2
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 5253f62b251f83d1ec41f81900111ed6b56a8107a1d86006516d73cc1b5e77ef

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

Research pending0% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5

How it works

Certificates

3 on fileUL 1741 · claimed
UL 1741Product / system scope unresolvedClaimedListed when checked

Manufacturer claim in the Product Safety Compliance or Grid Code Compliance row of NEP's BDM 600 product page, printed identically for the BDM 600 and BDM 600X columns and recorded exactly as printed. NEP adds "Refer to the label for the detailed grid code compliance". No certificate number or issuer is printed beside it, and no issuer directory was checked.

Models: BDM 600, BDM 600X

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier document
CSA C22.2 No. 107.1Product / system scope unresolvedClaimedListed when checked

Manufacturer claim in the Product Safety Compliance or Grid Code Compliance row of NEP's BDM 600 product page, printed identically for the BDM 600 and BDM 600X columns and recorded exactly as printed. NEP adds "Refer to the label for the detailed grid code compliance". No certificate number or issuer is printed beside it, and no issuer directory was checked.

Models: BDM 600, BDM 600X

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier document
IEEE 1547Product / system scope unresolvedClaimedListed when checked

Manufacturer claim in the Product Safety Compliance or Grid Code Compliance row of NEP's BDM 600 product page, printed identically for the BDM 600 and BDM 600X columns and recorded exactly as printed. NEP adds "Refer to the label for the detailed grid code compliance". No certificate number or issuer is printed beside it, and no issuer directory was checked.

Models: BDM 600, BDM 600X

Issued
Not stated
Valid from
Not stated
Expiry
Not stated
Issuer checked
Not checked
Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
BDM-600
Published model / SKU
BDM-300X2

NEP prints "BDM-600 (BDM-300X2)" as the heading of its BDM-600 technical sheet.

Official document: NEP BDM-600 (BDM-300X2) Microinverter technical sheet Checked · Earlier document

Manufacturer SKU BDM-600 · US market

Observed

UL 1741: claimed

Product / system scope unresolved. Manufacturer claim in the Product Safety Compliance or Grid Code Compliance row of NEP's BDM 600 product page, printed identically for the BDM 600 and BDM 600X columns and recorded exactly as printed. NEP adds "Refer to the label for the detailed grid code compliance". No certificate number or issuer is printed beside it, and no issuer directory was checked.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier document
Observed

CSA C22.2 No. 107.1: claimed

Product / system scope unresolved. Manufacturer claim in the Product Safety Compliance or Grid Code Compliance row of NEP's BDM 600 product page, printed identically for the BDM 600 and BDM 600X columns and recorded exactly as printed. NEP adds "Refer to the label for the detailed grid code compliance". No certificate number or issuer is printed beside it, and no issuer directory was checked.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier document
Observed

IEEE 1547: claimed

Product / system scope unresolved. Manufacturer claim in the Product Safety Compliance or Grid Code Compliance row of NEP's BDM 600 product page, printed identically for the BDM 600 and BDM 600X columns and recorded exactly as printed. NEP adds "Refer to the label for the detailed grid code compliance". No certificate number or issuer is printed beside it, and no issuer directory was checked.

Official product page: NEP BDM 600 Microinverter product page (captured September 24, 2026) Checked · Earlier document

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.