About brandMPP Solar Inc., based in Taipei, Taiwan, makes off-grid and hybrid solar inverters, MPPT charge controllers and lithium battery storage, and publishes catalogs and user manuals for current and legacy models on its Download Center.
SKU detail
locator: Download Center, LEGACY MODELS list; Split Phase LV series page, LV2424 section
conditions: Model name as printed by MPP Solar on its Download Center and series page. The catalog prints it as "LV 2424"; the user manual names the column 2.4KW. No other ordering code is printed.
Printed by the catalog. The manual's Nominal Output Voltage row prints two values (220/230/240 VAC and 101/110/120 VAC) across six columns, consistent with this value.
Where: Catalog STANDARD RATING, Nominal Output Volt
Printed as ">95%" by the catalog; a lower bound, not further defined. The manual's efficiency rows print two values across six columns ("Efficiency (DC to AC) 93% 90%"), so the 2.4KW value there is not certain and is not recorded.
Printed by the catalog. The manual's "MPPT Range @ Operating Voltage" row (PDF page 30) prints four values across six columns, so its 2.4KW value is not certain.
Where: Catalog PV INPUT / SOLAR CHARGING, MPPT Range
Grid Injection feature is available by feeding excess PV power to grid
Printed by the series page with "*please check with your local authority for compliance". The catalog adds that grid-injection must be disabled when a generator is the AC input and that grid feedback should remain disabled in a split-phase setup.
Row for 1KW, 2KW, 2.4KW, 3KW and 4KW: typical amperage 140A, battery capacity 200AH, one 2 AWG cable (38 mm2, ring terminal D 6.4 mm, L 39.2 mm) or two 6 AWG cables (28 mm2, D 6.4 mm, L 33.2 mm). The parallel guide (PDF page 34) prints 1*4AWG (22 mm2) or 2*6AWG (14 mm2) for each unit in a parallel system.
Where: Manual PDF page 7, Recommended battery cable and terminal size
The manual asks for a separate DC over-current protector and gives the typical amperage, 140A for this row, as the required fuse or breaker size. The parallel guide (PDF page 35) prints a 125A/30VDC battery breaker for each 2.4KW unit in a parallel system.
Up to 9 units in single phase (parallel kits required). The catalog footnote prints "*8 units max per phase in 2-phase / 7 units max per phase in 3-phase"; the series page says split phase parallel is limited to 8 units in total (4 in each phase).
Where: Manual PDF page 32, parallel guide; catalog, Maximum Parallel
The manual prints the rated output (as spelled, "RATED OUPUT POWER") in six model columns; 2400W is the 2.4KW column, the last. The catalog prints "Continuous Output 2400W". Manufacturer claim, not an independent test.
Where: Manual PDF page 30, SPECIFICATIONS, RATED OUPUT POWER row, 2.4KW column; catalog STANDARD RATING, Continuous Output
16.57 L* (Calculated from published dimensions)W: 295 × H: 468 × D: 120 mm / W: 11.6 × H: 18.4 × D: 4.72 inWeight11 kg / 24 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
Location: SPECIFICATIONS (PDF page 30); installation (PDF pages 6 to 9); parallel guide (PDF pages 32 to 35)
Retrieved Oct 15, 2026
The user manual the Download Center links for the LV2424, captured on October 15, 2026; the primary source for the LV2424. It covers six models (1KW, 2KW, 3KW, 4KW, 5KW and 2.4KW); figures are read from the 2.4KW column, the last of the specification table (PDF page 30), and from rows that name the 2.4KW. Rows printing fewer values than columns are not used. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by MPP Solar Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: STANDARD RATING table and MAIN FEATURES, page 1
Retrieved Oct 15, 2026
MPP Solar's one-page LV2424 catalog, linked from the Download Center and captured on October 15, 2026. It covers the LV2424 only. Manufacturer claims, not independent tests; no revision date is printed.
Archived copies
Archived copy of a document published by MPP Solar Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
MPP Solar's series page for the Split Phase LV inverters, captured on October 15, 2026. It describes the LV2424 and states that the LV5048 has been discontinued. Manufacturer statements; the page carries no revision date.
Location: Model list; TERM DEFINITION; LEGACY MODELS
Retrieved Oct 15, 2026
MPP Solar's Download Center at www.mppsolar.com, captured on October 15, 2026. It lists each model with its maker label (off-grid or hybrid, defined on the page) and links its catalog and user manual; models no longer current are listed under LEGACY MODELS with "(legacy)". The page carries no revision date.
MPP Solar user manual: Hybrid 1KW-5KW Inverter / Charger, version 1.2 (LV2424 user manual, file dated 20230915) (October 15, 2026 capture)
Archived copy of a document published by MPP Solar Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
MPP Solar catalog: Split Phase LV Series LV 2424 (October 15, 2026 capture)
Archived copy of a document published by MPP Solar Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].