300A DC breaker (or fuse) between the Rosie and the battery bank on the positive cable[1]
PV disconnect
?
Clearances and orientation
Installation clearances
allow at the minimum an airspace clearance of 6” at the vents and 3” everywhere else to provide adequate ventilation[1]
Mounting orientation
Mount vertically on a flat, non-combustible surface with DC terminals pointing down[1]
Grounding
Grounding and neutral-ground bonding
Each electrical system is required to be connected to a permanent, common, ground or earth reference.[1]
Communication
Communication ports
CANBUS Terminals (#1) Connect Ethernet cable between the Rosie and the MNGPS and/or between other CANBUS- enabled devices.[1]
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.