Brand
MidNite Solar
Model
MNLR3648M
SKU / part number
?
Category
Inverters

chargedreviews.com/inverters/midnite-solar-mnlr3648m

AC output

Continuous output
3.6 kW [1]
Peak output
More than 5,400 W for 5 s; 5,400 W for 30 s; 4,500 W for 5 min; 3,690 W for 30 min [1]
AC configuration
?
AC output voltage
120 V [1]
AC frequency
60 [1]
Grid pass-through
30 A [1]
Maximum output per leg
?

Battery

Battery voltage
?
Battery voltage range
40 to 63 [1]
Maximum charge current
60 A [1]
Maximum discharge current
?
Battery-only output
?
Maximum grid charging
?
Compatible batteries / BMS
?

PV input

PV array limit (connected)
?
PV input limit (converted)
?
Maximum PV voltage (Voc)
?
MPPT voltage range
?
MPPT trackers
?
String inputs per MPPT
?
PV current per MPPT
?
PV short-circuit current
?
PV startup voltage
?

Efficiency and modes

Peak efficiency
95 % [1]
CEC weighted efficiency
?
Battery conversion efficiency
?
Grid / off-grid modes
Internal 30-amp AC transfer switch; allowing the incoming AC power to continue powering the loads even if the inverter is off [1]
Generator input
Takes alternating current (when connected to a generator or to utility power) and transforms it into direct current to charge your batteries [1]
Transfer time
4 ms [1]
Idle consumption
?
Parallel units
?

Communication and environment

Communications
CAN [1]
Operating temperature
-20 to 60 [1]
Enclosure rating
?
Operating noise
?

Mechanical

Dimensions
W 229 × H 151 × L 514 mm / W 9.02 × H 5.94 × L 20.2 in converted [1]
Weight
6.8 kg / 15 lb converted [1]

Installation (from the manual)

Conductors

Battery conductors
#4 AWG (21.2 mm²) [125 amps] (Minimum DC Wire Size, 75°C rating in free air) [1]
AC input conductors
Minimum wire size of #10 AWG (5.3 mm²) [1]
AC output conductors
Minimum cable size of #8 AWG (8.4 mm²) on the inverter’s output [1]
PV conductors
?
Ground conductor
#6 AWG (13.3 mm²) (DC Grounding Electrode Wire Size) [1]

Protection

AC input breaker
30-amp continuous duty rated breaker [1]
AC output breaker
?
Battery fuse or breaker
DC fuse, 125 amps with time delay [1]
PV disconnect
?

Clearances and orientation

Installation clearances
Provide at least 3 inches (7.5 cm) of airspace clearance at the intake and exhaust vents to provide adequate ventilation. [1]
Mounting orientation
Shelf or wall [1]

Grounding

Grounding and neutral-ground bonding
Inverter power systems must always be connected to a grounded wiring system. [1]

Communication

Communication ports
CAN/Remote Connection Port: a RJ45 port that accepts optional CAN capable accessories; or for connecting a MidNite Remote control [1]

Not in the manual: Torque

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

MidNite Solar MNLR3648M · MNLR3648M

Warranty

Warranty term5 years[1]
Optional extension?
Coverage starts?
Coverage conditionsMidNite Solar Inc. warrants to the original customer that the MNLR3648M Inverter/Charger shall be free from defects in materials and workmanship[1]
RemedyAt its option, MidNite Solar will repair or replace at no charge any MidNite product that proves to be defective within such warranty period[1]
Labor and shippingPurchasers must prepay all delivery costs or shipping charges to return any defective MidNite Solar product under this warranty policy[1]
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741?
UL 1741 SA?
UL 1741 SB?
IEEE 1547?
CA Rule 21?
UL 9540?
FCC Part 15?
CSA C22.2Claimed [1]

Documents and sources

  1. MidNite Solar Little Rosie Inverter/Charger Owner's Manual MNLR3648M (Mobile Version), 10-586-1 Rev A Manufacturer manual · Checked Sep 9, 2026 https://www.midnitesolar.com/pdfs/10-586-1W%2C_Rev_A_%28Owners_Manual%2C_MNLR3648M%29.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.