3 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "3 yr Warranty" in the headline figures of the DMX Power family page, for the family.
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 10.9 kg / 24 lb converted | Unit weight, printed as "24 lbs. (10.9 kg)" in the Weight row; the kilogram figure is recorded. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Weight row | [2] |
| Peak output | 1650 W for 5 s; 1600 W for 30 s; 1250 W for 5 min; 1200 W for 30 min | The manual's surge rows print 1650W (5 sec), 1600W (30 sec), 1250W (5 min) and 1200W (30 min) for this model. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, 5 sec surge power row | [2] |
| Voltage thd | <5% | Printed as <5% in the Total Harmonic Distortion row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Total Harmonic Distortion row | [2] |
| AC voltage | 120 V | Printed as "120 VAC +/– 5%" in the Nominal AC output voltage row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Nominal AC output voltage row | [2] |
| Idle standby | 5 W search mode (typical, with no remote); 22 W inverting with no load (typical) | Printed as "5W typical (with no remote)" in the Power Draw: Search mode row, and as "22W typical (with no remote)" in the Power Draw: ON (no load) row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Power Draw: Search mode row | [2] |
| Max charge | 50 A | Continuous charger output, printed as "50 ADC" in the Continuous output @ 45°C row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Continuous output @ 45°C row | [2] |
| Clearances | At the minimum, allow an airspace clearance of 3” (7.5 cm) on all sides to provide adequate ventilation. | Printed as "At the minimum, allow an airspace clearance of 3” (7.5 cm) on all sides to provide adequate ventilation" in the MMSA1012 Owner's Manual (64-0073 Rev D, April 2023). Where: PDF page 19, Ventilation | [2] |
| Dimensions | W 213 × H 171 × L 422 mm / W 8.39 × H 6.73 × L 16.6 in converted | Printed as "42.2 cm x 21.3 cm x 17.1 cm" in the Dimensions (L x W x H) row, in the axis order the row names (length x width x height); the centimeter figures are recorded in millimeters. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Dimensions (L x W x H) row SourcesConverted: 42.2 cm x 10 = 422 mm; 21.3 cm x 10 = 213 mm; 17.1 cm x 10 = 171 mm | [2] |
| Efficiency | 87 % | Peak inverter efficiency, printed as 87% in the Inverter efficiency (max) row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Inverter efficiency (max) row | [2] |
| AC frequency | 60 Hz | Printed as "60 Hz +/– 0.1 Hz" in the Output frequency and accuracy row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Output frequency and accuracy row | [2] |
| Output waveform | Pure sine wave | Printed as "Output AC waveform type Pure Sine Wave". Where: PDF page 54, MMSA1012 Owner's Manual specifications table, waveform row | [2] |
| Ground wire size | #6 AWG (13.3 mm2) | Read from Table 2-1, Recommended DC Wire/Overcurrent Device in the MMSA1012 Owner's Manual (64-0073 Rev D, April 2023), the DC grounding electrode wire size printed for the MMSA1012. Where: PDF page 23, Table 2-1, Recommended DC Wire/Overcurrent Device, MMSA1012 row | [2] |
| Transfer time | 16 ms | Printed as "16 msecs" in the Transfer time (typical) row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Transfer time (typical) row | [2] |
| Apparent power | 1,000 VA | Printed as "1000 VA" in the Continuous power output @ 45°C row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Continuous power output @ 45°C row | [2] |
| Battery wire size | #2 AWG (33.6 mm2) [170 amps] | Read from Table 2-1, Recommended DC Wire/Overcurrent Device in the MMSA1012 Owner's Manual (64-0073 Rev D, April 2023), the minimum DC wire size printed for the MMSA1012. Where: PDF page 23, Table 2-1, Recommended DC Wire/Overcurrent Device, MMSA1012 row | [2] |
| Nominal voltage | 12 V | Printed as 12 VDC in the DMX Power page's Charging table row for the MMSA1012. Where: Page Charging table, DC System column | [1] |
| Surge AC output | 1,650 W | Printed as 1650W in the 5 sec surge power row, the five second surge power. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, 5 sec surge power row | [2] |
| Battery protection | 150 amps with time delay | Read from Table 2-1, Recommended DC Wire/Overcurrent Device in the MMSA1012 Owner's Manual (64-0073 Rev D, April 2023), the DC fuse size printed for the MMSA1012. Where: PDF page 23, Table 2-1, Recommended DC Wire/Overcurrent Device, MMSA1012 row | [2] |
| Certification claims | ETL to UL/cUL458; CSA C22.2 #107.1-01; [UL 458:2015 Ed.6]; [UL 1741:2010 Ed.2+R:07Sep2016] | The UL listing row as printed once for every model of the table. Intertek's Authorization to Mark (issued 20 Apr 2018) names this exact code among the models "MMS1012, MMSA1012" and lists the standards [UL 458:2015 Ed.6] and [UL 1741:2010 Ed.2+R:07Sep2016]. Manufacturer claims; no issuer directory was checked. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, UL listing row | [2] [3] |
| Continuous output | 1 kWConverted: 1000 W / 1000 = 1 kW | Printed as 1000 W continuous on the DMX Power page row for the MMSA1012; the owner's manual prints 1000 VA in the Continuous power output @ 45°C row. 1000 W expressed in kW. Where: Page Power & Output table; PDF page 54, MMSA1012 Owner's Manual specifications table, Continuous power output @ 45°C row SourcesConverted: 1000 W / 1000 = 1 kW | [1] [2] |
| Battery compatibility | Lead-acid | Printed as battery type "Lead-acid" in the DMX Power page row for the MMSA1012. Where: Page Power & Output table, Battery column | [1] |
| Battery voltage range | 9 to 17 V | Printed as "9 to 17 VDC" in the Input battery voltage row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Input battery voltage row | [2] |
| Operating temperature | -20 to 60 °C / -4 to 140 °F converted | Operating temperature, printed as "-20° C to +60° C (-4° F to 140° F)" in the Operating temperature row. Where: PDF page 54, MMSA1012 Owner's Manual specifications table, Operating temperature row | [2] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
3 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "3 yr Warranty" in the headline figures of the DMX Power family page, for the family.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 3 years | Printed as "3 yr Warranty" in the headline figures of the DMX Power family page, for the family. Where: Page headline figures | [1] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Linked from DMX Power's MMSA Series family page and its Models & Specifications table; captured Nov 1, 2026 (archived copy).
Location: PDF page 23, Table 2-1; PDF page 54, Table 6-1, MMSA1012 Specifications
Retrieved Nov 1, 2026
The MMSA1012 Owner's Manual (64-0073 Rev D, April 2023), linked from DMX Power's MMSA Series family page and its Models & Specifications table and fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:34:14.641 UTC). DMX Power bought the Magnum Energy line in April 2025. Manufacturer claims, not independent tests.
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/product/manual/sensata-mmsa1012-pure-sine-wave-inverter-charger-manual.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 810434e42cc3cb90bdbe0e5a1cb4dc1c6e57d32d9f164f4379fe3ff0a43dbb02
Linked from DMX Power's MMS Series and MMSA Series pages, Certifications column; captured Nov 1, 2026 (archived copy).
Location: Standard(s), Product and Models fields
Retrieved Nov 1, 2026
Intertek's Authorization to Mark for the MMS1012 and MMSA1012 (UL 458, UL 1741 and CSA C22.2 No. 107.1), linked from DMX Power's MMS Series and MMSA Series pages, Certifications column and fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:37:30.064 UTC). DMX Power bought the Magnum Energy line in April 2025. Manufacturer claims, not independent tests.
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/document/compliance/mmsa/atm-mms1012-and-mmsa1012-ul458-ul1741-and-csa-issued-20-apr-2018.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 352cbd66f8ae5c7d925903c56754b302fa24aa9d3692f416648e68d4ab218731
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
DMX Power catalog page; captured Nov 1, 2026 (archived copy).
Location: Models & Specifications tables
Retrieved Nov 1, 2026
DMX Power's catalog page for the MMSA Series inverter/chargers, fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:12:32.257 UTC). DMX Power bought the Magnum Energy line in April 2025. Manufacturer claims, not independent tests.
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/product/manual/sensata-mmsa1012-pure-sine-wave-inverter-charger-manual.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 810434e42cc3cb90bdbe0e5a1cb4dc1c6e57d32d9f164f4379fe3ff0a43dbb02
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/document/compliance/mmsa/atm-mms1012-and-mmsa1012-ul458-ul1741-and-csa-issued-20-apr-2018.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 352cbd66f8ae5c7d925903c56754b302fa24aa9d3692f416648e68d4ab218731
No sourced accessories or replacement parts listed yet.
Manufacturer SKU MMSA1012 · US market
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 3 unit: Unknown shown: 3 years shown detail: Unknown state: documented points: 3.6 ceiling: 30 weight: 30 share: 12 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||