About brandMagnum Series inverters and inverter/chargers, including the MS, MS-PAE and MSH-RV Series, are published by DMX Power, LLC on dmx-power.com, where the catalog pages mark them Made in USA. DMX Power's Limited Warranty Policy names Magnum Series Inverters and Inverter Chargers among its products and says DMX Power makes power inverters for recreational vehicle, marine, fleet, renewable energy and off-grid systems.
conditions: Model number as printed in the DMX Power CSW Series page tables and in the heading of the owner's manual's Table 5-1 (its Table 5-1 heads its columns CSW412, CSW1012 and CSW2012).
The total harmonic distortion printed in the waveform row, "Pure sine wave (<3% THD)", in the AC Output Waveform row, printed once for every model of the table.
Where: PDF page 28, Table 5-1, AC Output Waveform row
W 175 × H 87 × L 200 mm / W 6.89 × H 3.4 × L 7.87 in convertedCheck note
Needs confirmation: DMX Power documents print two sets of dimensions. The CSW 12V Series Owner's Manual (64-0063 Rev J, March 2026) prints 7.9 x 6.9 x 3.4 in (200 x 175 x 87 mm, shown); the DMX Power family page prints 6.9 x 7.9 x 3.4 in for the CSW412.
Printed as "CSW412: 7.9 x 6.9 x 3.4” (20 x 17.5 x 8.7 cm)" in the Inverter Size (L x W x H) row, which prints one size per model (the CSW412 entry), in the axis order the row names (L x W x H); the centimeter figures are recorded in millimeters. The DMX Power page prints a different value, kept as an alternative; the owner's manual value is shown.
Where: PDF page 28, Table 5-1, Inverter Size (L x W x H) row
Sources
Converted: 20 cm x 10 = 200 mm; 17.5 cm x 10 = 175 mm; 8.7 cm x 10 = 87 mm
W 200.7 × H 86.4 × L 175.3 mm
Printed as 6.9" × 7.9" × 3.4" (inches) in the Dimensions column of the page row for the CSW412; the page names no axes, so the figures are read in the manual's order (length x width x height).
Printed as 90% in the Efficiency column of the DMX Power page row for the CSW412; the owner's manual prints optimum efficiency as >90% in the Optimum Efficiency row, printed once for every model of the table, so the figure is a lower bound.
Where: Page Power & Output table, Efficiency column; PDF page 28, Table 5-1, Optimum Efficiency row
Read from the CSW412 column (column 1 of 3) of Table 2-2, DC Wire/Overcurrent Device for Rated Use in the CSW 12V Series Owner's Manual (64-0063 Rev J, March 2026), the minimum DC ground wire size.
Where: PDF page 18, Table 2-2, DC Wire/Overcurrent Device for Rated Use, CSW412 column
Read from the CSW412 column (column 1 of 3) of Table 2-2, DC Wire/Overcurrent Device for Rated Use in the CSW 12V Series Owner's Manual (64-0063 Rev J, March 2026), the minimum DC wire size (75°C rating in free air).
Where: PDF page 18, Table 2-2, DC Wire/Overcurrent Device for Rated Use, CSW412 column
Peak surge power, printed as 800 W in the CSW412 column (column 1 of 3) of the Surge Power (Peak) row; the manual's note says surge ratings are based on resistive load (output voltage may drop).
Where: PDF page 28, Table 5-1, Surge Power (Peak) row
Read from the CSW412 column (column 1 of 3) of Table 2-2, DC Wire/Overcurrent Device for Rated Use in the CSW 12V Series Owner's Manual (64-0063 Rev J, March 2026), the maximum DC fuse size.
Where: PDF page 18, Table 2-2, DC Wire/Overcurrent Device for Rated Use, CSW412 column
Conforms to UL STD 458; Certified to CSA STD C22.2 No. 107.1
The Regulatory Approval row as printed for the models of the table. Manufacturer claims; no issuer directory was checked, and the row names no listing body.
Where: PDF page 28, Table 5-1, Regulatory Approval row
Printed as 400 W continuous on the DMX Power page row for the CSW412; the owner's manual prints 400 W in the CSW412 column (column 1 of 3) of the Continuous Power row. 400 W expressed in kW.
Where: Page Power & Output table; PDF page 28, Table 5-1, Continuous Power row
Printed as 52 to 58 lbf-in for the CSW412's DC terminals in Table 2-1, DC Terminal – Torque Requirements of the CSW 12V Series Owner's Manual (64-0063 Rev J, March 2026); stored as in-lb.
Where: PDF page 16, Table 2-1, DC Terminal – Torque Requirements, CSW412 row
Printed as 10–16 V in the Operating Range column of the DMX Power page row for the CSW412. The owner's manual's DC Operation Voltage Range row prints two ranges for its three model columns ("DC Operation Voltage Range3 10.5 – 15.75 10.5 – 15.5 VDC"), so the page's range is recorded.
Where: Page Charging table, Operating Range column
3.04 L* (Calculated from published dimensions)W: 175 × H: 87 × L: 200 mm / W: 6.89 × H: 3.4 × L: 7.87 inWeight1.7 kg / 3.7 lb
Evidence score
1/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term1 year1.2 / 30.0
1 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty One Year" in the Warranty row, printed once for every model of the table of the CSW 12V Series Owner's Manual (64-0063 Rev J, March 2026), and as "1 yr Warranty" in the DMX Power CSW Series page's headline figures.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
1 years
Printed as "Warranty One Year" in the Warranty row, printed once for every model of the table of the CSW 12V Series Owner's Manual (64-0063 Rev J, March 2026), and as "1 yr Warranty" in the DMX Power CSW Series page's headline figures.
Location: Table 5-1, CSW Series Specifications (printed page 23)
Retrieved Oct 14, 2026
DMX Power's owner's manual for the CSW412, CSW1012 and CSW2012, linked from the CSW1012 page and captured on October 15, 2026. Figures are read from the CSW1012 column (the second of three) of Table 5-1 (printed page 23) only where the value is printed per model or in a row that prints a single value for all models. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by DMX Power, LLC. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: Models & Specifications tables, CSW1012 and CSW1012-NG rows
Retrieved Nov 1, 2026
DMX Power's catalog page for the CSW Series, captured on November 2, 2026 at 06:10 UTC with the paced research fetcher (HTTP 200): the series description and headline figures and the model tables, which list the CSW1012 and the superseded CSW1012-NG, whose Superseded mark links to the CSW1012. Manufacturer statements, not independent tests; the page carries no revision date.
Archived copy of a document published by DMX Power, LLC. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].