Charged ReviewsSaved 0Compare 0Login
No photo yet
Magnum Energy
Off-grid inverter

Magnum Energy CSW2012-X Pure Sine Inverter

Key specs

Continuous output2 kW
Converted: 2000 W / 1000 = 2 kW
Weight5.9 kg / 13 lb converted Check note
Nominal voltage12 V
Efficiency90 %
Surge AC output4,000 W
AC voltage120 V

All specifications

Identity

BrandMagnum Energy · Website
ModelCSW2012-X
MarketUnknown
Manufacturer SKUCSW2012-X
About brandMagnum Series inverters and inverter/chargers, including the MS, MS-PAE and MSH-RV Series, are published by DMX Power, LLC on dmx-power.com, where the catalog pages mark them Made in USA. DMX Power's Limited Warranty Policy names Magnum Series Inverters and Inverter Chargers among its products and says DMX Power makes power inverters for recreational vehicle, marine, fleet, renewable energy and off-grid systems.
SKU detail
locator: Page Models & Specifications tables; PDF page 40, Table 5-1 heading
conditions: Model number as printed in the DMX Power CSW Series page tables and in the heading of the owner's manual's Table 5-1 (its Table 5-1 is for the CSW2012-X alone).
Sources: [1] [2]
FieldValueConditionsSource
Weight5.9 kg / 13 lb converted Check note
Needs confirmation: DMX Power documents print two weights. The CSW2012-X Owner's Manual (64-0074 Rev D, February 2026) prints 13 lb (shown); the DMX Power family page prints 11.5 lb for the CSW2012-X.
Inverter weight, printed as "13.0 lb (5.9 kg)" in the Inverter Weight row; the kilogram figure is recorded. The DMX Power page prints a different value, kept as an alternative; the owner's manual value is shown.
Where: PDF page 40, Table 5-1, Inverter Weight row
Sources
5.22 kg

Printed as 11.5 lb in the Weight column of the page row for the CSW2012-X.

[1]
[2] [1]
Voltage thd<3%
The total harmonic distortion printed in the waveform row, "Pure sine wave (<3% THD)", in the AC Output Waveform row.
Where: PDF page 40, Table 5-1, AC Output Waveform row
[2]
AC voltage120 V
Printed as "120 VAC RMS ± 5%" in the AC Output Voltage (12.5V) row.
Where: PDF page 40, Table 5-1, AC Output Voltage (12.5V) row
[2]
DimensionsW 230 × H 115 × L 435 mm / W 9.06 × H 4.53 × L 17.1 in converted Check note
Needs confirmation: DMX Power documents print two sets of dimensions. The CSW2012-X Owner's Manual (64-0074 Rev D, February 2026) prints 17.1 x 9.1 x 4.5 in (435 x 230 x 115 mm, shown); the DMX Power family page prints 16.5 x 9.1 x 4.3 in for the CSW2012-X.
Printed as "17.1 x 9.1 x 4.5” (43.5 x 23 x 11.5 cm)" in the Inverter Size (L x W x H) row, which prints one size per model (the CSW2012-X entry), in the axis order the row names (L x W x H); the centimeter figures are recorded in millimeters. The DMX Power page prints a different value, kept as an alternative; the owner's manual value is shown.
Where: PDF page 40, Table 5-1, Inverter Size (L x W x H) row
Sources
Converted: 43.5 cm x 10 = 435 mm; 23 cm x 10 = 230 mm; 11.5 cm x 10 = 115 mm
W 231.1 × H 109.2 × L 419.1 mm

Printed as 16.5" × 9.1" × 4.3" (inches) in the Dimensions column of the page row for the CSW2012-X; the page names no axes, so the figures are read in the manual's order (length x width x height).

[1]
[2] [1]
Efficiency90 %
Printed as 90% in the Efficiency column of the DMX Power page row for the CSW2012-X; the owner's manual prints optimum efficiency as >90% in the Optimum Efficiency row, so the figure is a lower bound.
Where: Page Power & Output table, Efficiency column; PDF page 40, Table 5-1, Optimum Efficiency row
[1] [2]
AC frequency60 Hz
Printed as "60 Hz ± 0.5 Hz" in the AC Output Frequency row.
Where: PDF page 40, Table 5-1, AC Output Frequency row
[2]
Output waveformPure sine wave
Printed as "Pure sine wave (<3% THD)" in the AC Output Waveform row.
Where: PDF page 40, Table 5-1, AC Output Waveform row
[2]
Ground wire size#8 AWG (8.36 mm²)
Read from Table 2-2, DC Wire/Overcurrent Device for Rated Use in the CSW2012-X Owner's Manual (64-0074 Rev D, February 2026), the minimum DC ground wire size printed for the CSW2012-X (the text layer prints the row's values before its labels: full load current, maximum continuous current, ground wire, DC wire and fuse, in that order).
Where: PDF page 16, Table 2-2, DC Wire/Overcurrent Device for Rated Use, CSW2012-X row
[2]
Transfer time30 ms
AC transfer switch transfer time, printed as "< 30 ms" in the Transfer Time row; the figure is an upper bound.
Where: PDF page 40, Table 5-1, Transfer Time row
[2]
Battery wire size#2/0 AWG (67.4 mm²) [300 amps]
Read from Table 2-2, DC Wire/Overcurrent Device for Rated Use in the CSW2012-X Owner's Manual (64-0074 Rev D, February 2026), the minimum DC wire size printed for the CSW2012-X (the text layer prints the row's values before its labels: full load current, maximum continuous current, ground wire, DC wire and fuse, in that order).
Where: PDF page 16, Table 2-2, DC Wire/Overcurrent Device for Rated Use, CSW2012-X row
[2]
Nominal voltage12 V
Printed as 12 VDC in the DMX Power page's Charging table row for the CSW2012-X.
Where: Page Charging table, DC System column
[1]
Surge AC output4,000 W
Peak surge power, printed as "4000 W" in the Surge Power (Peak) row; the manual's note says surge ratings are based on resistive load (output voltage may drop).
Where: PDF page 40, Table 5-1, Surge Power (Peak) row
[2]
AC terminal torque5 to 8 in-lb
Printed as 5 - 8 lbf-in for the AC Terminals in Table 2-1, Torque Requirements of the CSW2012-X Owner's Manual (64-0074 Rev D, February 2026); stored as in-lb.
Where: PDF page 14, Table 2-1, Torque Requirements, AC Terminals row
[2]
Battery protection300 amps with time delay
Read from Table 2-2, DC Wire/Overcurrent Device for Rated Use in the CSW2012-X Owner's Manual (64-0074 Rev D, February 2026), the maximum DC fuse size printed for the CSW2012-X (the text layer prints the row's values before its labels: full load current, maximum continuous current, ground wire, DC wire and fuse, in that order).
Where: PDF page 16, Table 2-2, DC Wire/Overcurrent Device for Rated Use, CSW2012-X row
[2]
Certification claimsConforms to UL STD 458; Certified to CSA STD C22.2 No. 107.2-01; FCC Part 15 Class B
The Regulatory Approval row as printed for the models of the table. Manufacturer claims; no issuer directory was checked, and the row names no listing body.
Where: PDF page 40, Table 5-1, Regulatory Approval row
[2]
Continuous output2 kW
Converted: 2000 W / 1000 = 2 kW
Printed as 2000 W continuous on the DMX Power page row for the CSW2012-X; the owner's manual prints 2000 W in the Continuous Power row. 2000 W expressed in kW.
Where: Page Power & Output table; PDF page 40, Table 5-1, Continuous Power row
Sources
Converted: 2000 W / 1000 = 2 kW
[1] [2]
Continuous AC output16.6 A
AC output current, printed as "16.6 AAC" in the AC Output Current row.
Where: PDF page 40, Table 5-1, AC Output Current row
[2]
Ground terminal torque79 to 96 in-lb
Printed as 79 to 96 lbf-in for the DC Ground in Table 2-1, Torque Requirements of the CSW2012-X Owner's Manual (64-0074 Rev D, February 2026); stored as in-lb.
Where: PDF page 14, Table 2-1, Torque Requirements, DC Ground row
[2]
Battery terminal torque16 to 21 ft-lb
Printed as 16 to 21 lbf-ft for the DC Terminals in Table 2-1, Torque Requirements of the CSW2012-X Owner's Manual (64-0074 Rev D, February 2026); stored as ft-lb.
Where: PDF page 14, Table 2-1, Torque Requirements, DC Terminals row
[2]
Battery voltage range10.5 to 15.5 V Check note
Needs confirmation: DMX Power documents print two battery voltage ranges. The CSW2012-X Owner's Manual (64-0074 Rev D, February 2026) prints a DC operation voltage range of 10.5 to 15.5 VDC (shown); the DMX Power family page prints an operating range of 10 to 16 V for the CSW2012-X.
DC operation voltage range, printed as "10.5 - 15.5" in the DC Operation Voltage Range row. The DMX Power page prints a different value, kept as an alternative; the owner's manual value is shown.
Where: PDF page 40, Table 5-1, DC Operation Voltage Range row
Sources
10 to 16 V

Printed as 10–16 V in the Operating Range column of the page row "CSW2012-X 12 VDC 10–16 V".

[1]
[2] [1]
Operating temperature0 to 40 °C / 32 to 104 °F converted
Operating temperature, printed as "32°F to 104°F (0°C to 40°C)" in the Operating Temperature row.
Where: PDF page 40, Table 5-1, Operating Temperature row
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
2 kW
Battery voltage
10.5 to 15.5 V
Solar input
Not statedMPPT trackers Not stated
AC output
120 V
Warranty
1 year
Size
11.51 L* (Calculated from published dimensions)W: 230 × H: 115 × L: 435 mm / W: 9.06 × H: 4.53 × L: 17.1 inWeight 5.9 kg / 13 lb

Evidence score

1/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term1 year1.2 / 30.0

1 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "Warranty One Year" in the Warranty row of the CSW2012-X Owner's Manual (64-0074 Rev D, February 2026), and as "1 yr Warranty" in the DMX Power CSW Series page's headline figures.

[2] [1]

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Warranty term1 years
Printed as "Warranty One Year" in the Warranty row of the CSW2012-X Owner's Manual (64-0074 Rev D, February 2026), and as "1 yr Warranty" in the DMX Power CSW Series page's headline figures.
Where: PDF page 40, Table 5-1, Warranty row; page headline figures
[2] [1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • CSW2012-X Owner's Manual (64-0074 Rev D, February 2026) (November 2, 2026 capture)Official · DMX Power · Official instruction manual · PDF
    Source details
    Revision
    64-0074 Rev D
    Revision date
    Not stated

    Linked from DMX Power's CSW Series family page and its Models & Specifications table; captured Nov 1, 2026 (archived copy).

    Location: PDF page 14, Table 2-1; PDF page 16, Table 2-2; PDF page 40, Table 5-1, CSW2012-X Specifications

    Retrieved Nov 1, 2026

    The CSW2012-X Owner's Manual (64-0074 Rev D, February 2026), linked from DMX Power's CSW Series family page and its Models & Specifications table and fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 07:19:16.114 UTC). DMX Power bought the Magnum Energy line in April 2025. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup64-0074 Rev D · 3.76 MB

    Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/document/manual/64-0074-W%20D%20Owner%27s%20Manual%2C%20CSW2012-X.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    49

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 46eb43b79d213ef317e10afc613dbf75549759a3232e7498e4e2d4f56ea16a4e

    Open
  • Other documents

  • CSW Series page (DMX Power, November 2, 2026 capture)Official · DMX Power · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-11-02.

    Location: Models & Specifications tables, CSW1012 and CSW1012-NG rows

    Retrieved Nov 1, 2026

    DMX Power's catalog page for the CSW Series, captured on November 2, 2026 at 06:10 UTC with the paced research fetcher (HTTP 200): the series description and headline figures and the model tables, which list the CSW1012 and the superseded CSW1012-NG, whose Superseded mark links to the CSW1012. Manufacturer statements, not independent tests; the page carries no revision date.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

CSW2012-X Owner's Manual (64-0074 Rev D, February 2026) (November 2, 2026 capture)

Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup64-0074 Rev D · 3.76 MB

Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/document/manual/64-0074-W%20D%20Owner%27s%20Manual%2C%20CSW2012-X.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
49

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 46eb43b79d213ef317e10afc613dbf75549759a3232e7498e4e2d4f56ea16a4e

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
CSW2012-X

Manufacturer SKU CSW2012-X

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 1
unit: Unknown
shown: 1 year
shown detail: Unknown
state: documented
points: 1.2
ceiling: 30
weight: 30
share: 4
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2] [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. CSW Series page (DMX Power, November 2, 2026 capture) (DMX Power · manufacturer · observed Nov 1, 2026)
  2. CSW2012-X Owner's Manual (64-0074 Rev D, February 2026) (November 2, 2026 capture) (DMX Power · manufacturer · 64-0074 Rev D · observed Nov 1, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details