Charged Reviews · Quick reference
Hoymiles HYS-6.0LV-USG1
- Brand
- Hoymiles
- Model
- HYS-6.0LV-USG1
- SKU / part number
- HYS-6.0LV-USG1 [1]
- Category
- Inverters
chargedreviews.com/inverters/hoymiles-hys-6-0lv-usg1
AC output
Battery
PV input
Efficiency and modes
Communication and environment
Mechanical
Installation (from the manual)
Torque
Conductors
- Battery conductors
- ?
- AC input conductors
- ?
- AC output conductors
- ?
- PV conductors
- ?
- Ground conductor
- Grid Ground Cable 8 AWG; Battery Ground Cable 8 AWG; EPS/GEN Ground Cable 8 AWG [2]
Protection
- AC input breaker
- GEN port recommended AC breaker 25 A/240 V [2]
- AC output breaker
- Recommended circuit breaker: Grid L1/L2 50 A; EPS/GEN L1/L2 25 A [2]
- Battery fuse or breaker
- two-pole DC breaker with OCP between inverter and battery (recommended 125 A) [2]
- PV disconnect
- integrated DC switch; recommended PV circuit breaker 20 A [2]
Clearances and orientation
Grounding
- Grounding and neutral-ground bonding
- ground cables (battery, grid, EPS/GEN) to the inverter grounding bar; PV positive and negative not grounded [2]
Communication
- Communication ports
- Parallel; BMS; Meter; DI; EPO_P/EPO_N; DO1; DO2; USB port (DTS) [2]