Hoymiles HYS-11.5LV-USG1
- Brand
- Hoymiles
- Model
- HYS-11.5LV-USG1
- SKU / part number
- HYS-11.5LV-USG1 [1]
- Category
- Inverters
chargedreviews.com/inverters/hoymiles-hoy11-5ka
AC output
Battery
- Battery voltage
- 48 V [1]
- Maximum grid charging
- ?
- Compatible batteries / BMS
- ?
PV input
Efficiency and modes
- Grid / off-grid modes
- ?
- Generator input
- A generator can be connected to the GRID port or GEN port, and multiple generators only can be connected to the GRID port [2]
- Idle consumption
- ?
Communication and environment
- Communications
- RS485; CAN; Wi-Fi (optional); Ethernet (optional); 4G (optional) [1]
- Operating noise
- ?
Mechanical
Installation (from the manual)
Torque
- AC terminal torque
- ?
- Battery terminal torque
- 22.6 N·m [2]
- PV terminal torque
- ?
- Ground terminal torque
- ?
Conductors
- Battery conductors
- 4/0 AWG copper, 90℃/194℉ [2]
- AC input conductors
- 3-1 AWG copper, 90℃/194℉ (grid L1/L2, recommended cable range) [2]
- AC output conductors
- 8 AWG copper, 90℃/194℉ (EPS/GEN L1/L2/N, recommended) [2]
- PV conductors
- 12 AWG copper, 90℃/194℉ (recommended; cable range 14-6 AWG) [2]
- Ground conductor
- 8 AWG copper, 90℃/194℉ (Grid Ground Cable, recommended) [2]
Protection
Clearances and orientation
- Installation clearances
- ?
- Mounting orientation
- Wall mounting [2]
Communication
- Communication ports
- Parallel (CANH, CANL, 485B_1, 485A_1, 485B_2, 485A_2): for parallel operation; BMS (NTC+, NTC-, CANH, CANL, 485A, 485B); Meter (485A1, 485B1, 485A2, 485B2): for the smart meter; DI (DI_A, DI_B): dry contact input of external bypass contactor; EPO_P/EPO_N: for external Emergency Power Off switch; DO1 (NO1, COM1): dry contact output; DO2 (NO2, COM2): dry contact output [2]
Not in the manual: Grounding