Charged ReviewsSaved 0Compare 0Login
Hoymiles
Hybrid inverter

Hoymiles HIT-12L-G3S

Key specs

Weight41 kg / 90 lb converted
Continuous output12 kW
Converted: 12000 W / 1000 = 12 kW
Max PV voltage1,000 V
Efficiency98.5 %
Max charge250 A
MPPT count4

1 spec not documented yet: transfer timeHelp fill in ›

All specifications

Identity

BrandHoymiles · Website
ModelHIT-12L-G3S
MarketGlobal
Manufacturer SKUHIT-12L-G3S
About brandHoymiles Power Electronics makes microinverters, single- and three-phase hybrid inverters and module-level rapid shutdown hardware; its North American single-phase hybrid line is sold as the HYS-LV-USG1 series.
SKU detail
locator: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, Model row, HIT-12L-G3S column (fifth of 8)
conditions: Hoymiles' own model name, printed in the Model row of the manual's technical table ("Model HIT-5L-G3S HIT-6L-G3S ... HIT-20L-G3S") and as "HIT-12L-G3/ HIT-12L-G3S" in the data sheet's Model row.
Sources: [1] [2]
FieldValueConditionsSource
Weight41 kg / 90 lb converted
Printed as "Weight (kg) 41", one cell shared by all 8 models. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, General, Weight, one cell shared by all 8 models
[1] [2]
MPPT count4
Printed as "4/4" (MPPT number/max. input strings number) in the HIT-12L-G3S column: 4 MPPTs and at most 4 input strings. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, PV Input, MPPT number/Max. input strings number, HIT-12L-G3S column (fifth of 8)
[1] [2]
Peak output24000 VA for 10 s (back-up output)
The back-up maximum output apparent power row prints "24000, 10s" in the HIT-12L-G3S column. Footnote (2) reads "Can be achieved only if PV and battery power are sufficient." Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, AC Output (Back-up), Max. output apparent power (VA), HIT-12L-G3S column (fifth of 8)
[1] [2]
Max charge250 A
Printed as "250/250" (charge/discharge) in the HIT-12L-G3S column; the charge figure is recorded. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, Battery, Max. charge/discharge current (A), HIT-12L-G3S column (fifth of 8)
[1] [2]
DimensionsW 539 × H 696 × D 232 mm / W 21.2 × H 27.4 × D 9.13 in converted
Printed as "Dimensions (W × H × D [mm]) 539 × 696 × 232", width by height by depth, one cell shared by all 8 models; footnote (3) reads "Excluding Connectors and Brackets." Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, General, Dimensions, one cell shared by all 8 models
[1] [2]
CommunicationsRS485; Wi-Fi (optional); Ethernet (optional); 4G (optional)
Printed as "Communication RS485, Wi-Fi/Ethernet/4G (optional)", one cell shared by all 8 models; the battery communication is printed as CAN. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, General, Communication, one cell shared by all 8 models
[1] [2]
Efficiency98.5 %
Printed as 98.5% in the HIT-12L-G3S column of the row "Max. efficiency"; the MPPT efficiency row prints 99.9%. A manufacturer claim. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, Efficiency, Max. efficiency, HIT-12L-G3S column (fifth of 8)
[1] [2]
MPPT voltage150 to 900 V
Printed as "MPPT voltage range (V) 150-900", one cell shared by all 8 models. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, PV Input, MPPT voltage range (V), one cell shared by all 8 models
[1] [2]
Max discharge250 A
Printed as "250/250" (charge/discharge) in the HIT-12L-G3S column; the discharge figure is recorded. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, Battery, Max. charge/discharge current (A), HIT-12L-G3S column (fifth of 8)
[1] [2]
AC configurationThree-phase grid: 380/400 V (266 to 480 V), 50/60 Hz, 3L/N/PE; back-up output: 380/400 V, 50/60 Hz, 3L/N/PE
Printed as "Rated AC output voltage/Range (V) 380/400, 266-480" with grid form 3L/N/PE and rated grid frequency 50/60 Hz, and for the back-up output "Rated output voltage (V) 380/400" at 50/60 Hz, one cell shared by all 8 models. The manual also prints a maximum continuous AC bypass current of 50 A. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, AC Input and Output (On-grid) and AC Output (Back-up), one cell shared by all 8 models
[1] [2]
Backup output12 kW
Converted: 12000 W / 1000 = 12 kW
Back-up rated output power printed as 12000 W in the HIT-12L-G3S column; recorded in kW. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, AC Output (Back-up), Rated output power (W), HIT-12L-G3S column (fifth of 8)
Sources
Converted: 12000 W / 1000 = 12 kW
[1] [2]
Enclosure ratingIP66
Printed as "Protection degree IP66", one cell shared by all 8 models. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, General, Protection degree, one cell shared by all 8 models
[1] [2]
Max PV current20 A
Printed as "20/20/20/20" in the HIT-12L-G3S column, one figure per MPPT; the per-MPPT figure is recorded. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, PV Input, Max. input current (A), HIT-12L-G3S column (fifth of 8)
[1] [2]
Max PV voltage1,000 V
Printed as "Max. input voltage (V) 1000" in the PV Input section, one cell shared by all 8 models; rated voltage 720 V. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, PV Input, Max. input voltage (V), one cell shared by all 8 models
[1] [2]
Transfer timeUnknown
Not recorded: the manual prints <0 ms; the data sheet prints <10 ms; the two documents differ.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, AC Output (Back-up), Back-up switch time (ms); Hoymiles' Global data sheet (REV1.8), PDF page 2, AC Output (Back-up), Back-up switch time (ms)
[1] [2]
Apparent power13,200 VA
Maximum on-grid output apparent power printed as 13200 VA in the HIT-12L-G3S column. Footnote (1) reads "For Belgium, the maximum output apparent power is equal to the nominal output apparent power." Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, AC Input and Output (On-grid), Max. output apparent power (VA), HIT-12L-G3S column (fifth of 8)
[1] [2]
PV start voltage150 V
Printed as "Start-up voltage (V) 150", one cell shared by all 8 models. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, PV Input, Start-up voltage (V), one cell shared by all 8 models
[1] [2]
Certification claimsEN 50549; PN-EN 50549; TOR Erzeuger Type A; VDE 4105; NF EN 0549; RD 647; UNE 217001 217002; SR EN 50549; G98; G99; RETIE; BIS; IEC 61727; IEC 62116; IEC 61683; IEC 60068; AS/NZS 4777.2:2020; IEC 62109-1/-2; EN 61000-6-1/-2/-3/-4
As printed in the Certifications and Standards section, one cell shared by all 8 models: grid connection standard "EN 50549, PN-EN 50549, TOR Erzeuger Type A, VDE 4105, NF EN 0549, RD 647, UNE 217001 217002, SR EN 50549, G98, G99, RETIE, BIS, IEC 61727, IEC 62116, IEC 61683, IEC 60068, AS/NZS 4777.2:2020" and safety/EMC standard "IEC 62109-1/-2, EN 61000-6-1/-2/-3/-4" (each entry recorded exactly as printed). Manufacturer claims; no certificate or listing directory was checked. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, Certifications and Standards, one cell shared by all 8 models
[1] [2]
Continuous output12 kW
Converted: 12000 W / 1000 = 12 kW
On-grid rated output power printed as 12000 W in the HIT-12L-G3S column; recorded in kW. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, AC Input and Output (On-grid), Rated output power (W), HIT-12L-G3S column (fifth of 8)
Sources
Converted: 12000 W / 1000 = 12 kW
[1] [2]
Battery efficiency95.7 %
Printed as "Max. battery discharge to AC efficiency 95.7%", one cell shared by all 8 models. A manufacturer claim. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, Efficiency, Max. battery discharge to AC efficiency, one cell shared by all 8 models
[1] [2]
Max PV short circuit30 A
Printed as "30/30/30/30" in the HIT-12L-G3S column, one figure per MPPT; the per-MPPT figure is recorded. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, PV Input, Max. short circuit current (A), HIT-12L-G3S column (fifth of 8)
[1] [2]
Battery voltage range40 to 60 V
Printed as "Battery voltage range (V) 40-60", one cell shared by all 8 models; battery type printed as "Li-ion/Lead-acid". Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, Battery, Battery voltage range (V), one cell shared by all 8 models
[1] [2]
Operating temperature-25 to 65 °C / -13 to 149 °F converted
Printed as "Operating temperature (℃) -25 to +65 (>45, derating)", one cell shared by all 8 models: output derates above 45 ℃. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, General, Operating temperature, one cell shared by all 8 models
[1] [2]
Weighted efficiency98 %
Printed as 98.0% in the HIT-12L-G3S column of the row "EU efficiency" (EU weighted, not CEC weighted). A manufacturer claim. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.
Where: Hoymiles' Global user manual (REV1.1), PDF page 75 (printed page 71), section 13 Technical Datasheet, Efficiency, EU efficiency, HIT-12L-G3S column (fifth of 8)
[1] [2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
12 kW
Battery voltage
40 to 60 V
Solar input
Not statedMPPT trackers 4MPPT range 150 to 900 V
AC output
Three-phase grid: 380/400 V (266 to 480 V), 50/60 Hz, 3L/N/PE; back-up output: 380/400 V, 50/60 Hz, 3L/N/PE
Warranty
Not stated
Size
87.03 L* (Calculated from published dimensions)W: 539 × H: 696 × D: 232 mm / W: 21.2 × H: 27.4 × D: 9.13 inWeight 41 kg / 90 lb

Evidence score

15/100Missing details15% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Warranty term needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Battery conversion efficiency95.7 %14.6 / 15.0

95.7 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10

Printed as "Max. battery discharge to AC efficiency 95.7%", one cell shared by all 8 models. A manufacturer claim. Hoymiles' Global data sheet (REV1.8) prints the same value in its column for the HIT-12L-G3 and this model.

[1] [2]

Research pending, 0 points: Certificates, Warranty term, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Hoymiles User Manual, Three-phase Hybrid Inverter HIT-5L-G3S, HIT-6L-G3S, HIT-8L-G3S, HIT-10L-G3S, HIT-12L-G3S, HIT-15L-G3S, HIT-17L-G3S and HIT-20L-G3S, Region: Global, REV1.1Official · Hoymiles · Official user manual · PDF
    Source details
    Revision
    REV1.1
    Revision date
    Not stated

    Archived copy captured from Hoymiles' file host w3oss.hoymiles.com on October 10, 2026 at 02:37:54 UTC, obtained by Alternative Research by following the file link on Hoymiles' openly served download page https://www.hoymiles.com/downloads/hoymiles-user-manual-hit-5-20-l-g3s-global-en.html. The copy read hashes to the SHA-256 recorded for this source.

    Retrieved Oct 9, 2026

    Hoymiles' own user manual for the HIT-5L-G3S to HIT-20L-G3S three-phase hybrid inverters, cover printed "USER MANUAL Region: Global REV1.1" (Hoymiles' download catalog titles the file REV1.3; the document itself prints REV1.1). Read in full; its section 13 Technical Datasheet table (PDF page 75, printed page 71, one column per model) was also checked on the rendered page and is the primary source for these records. Hoymiles links this file from its own openly served download page https://www.hoymiles.com/downloads/hoymiles-user-manual-hit-5-20-l-g3s-global-en.html, where it was obtained; the file itself is on Hoymiles' file host at https://w3oss.hoymiles.com/uploadfile/1/202608/aa06b51275.pdf, which serves it only to requests that come from a hoymiles.com page. Manufacturer claims, not an independent test.

    Archived copies

    Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupREV1.1 · 21.88 MB

    Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202608/aa06b51275.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    92

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 1f50ff1b55e51b91775cedad567200201eb41b5bb6170dd7b336f31cd9abe570

    Open
  • Datasheets

  • Hoymiles Three-phase Hybrid Inverter Datasheet, HIT-(5-20)L-G3 and HIT-(5-20)L-G3S, Region: Global, REV1.8Official · Hoymiles · Official datasheet · PDF
    Source details
    Revision
    REV1.8
    Revision date
    Not stated

    Archived copy captured from Hoymiles' file host w3oss.hoymiles.com on October 10, 2026 at 02:28:37 UTC, obtained by Alternative Research by following the file link on Hoymiles' openly served download page https://www.hoymiles.com/downloads/hoymiles-datasheet-hit-5-20-l-g3-hit-5-20-l-g3s-global-en-rev1-5.html. The copy read hashes to the SHA-256 recorded for this source.

    Retrieved Oct 9, 2026

    Hoymiles' own two-page data sheet for the HIT series in its G3 (LED indicators) and G3S (LCD screen) versions, printed "Region: Global REV1.8"; each column covers one G3 model and its G3S counterpart. Read in full; its Technical Specifications table (PDF page 2) is the second source for the HIT-L-G3 records, after the user manual. Hoymiles links this file from its own openly served download page https://www.hoymiles.com/downloads/hoymiles-datasheet-hit-5-20-l-g3-hit-5-20-l-g3s-global-en-rev1-5.html, where it was obtained; the file itself is on Hoymiles' file host at https://w3oss.hoymiles.com/uploadfile/1/202609/57245db193.pdf, which serves it only to requests that come from a hoymiles.com page. Manufacturer claims, not an independent test.

    Archived copies

    Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupREV1.8 · 0.45 MB

    Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202609/57245db193.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: bcae366a9150bf0bf2cab2c7a3ba02dd94e41d8f5474a4926acfbff8dea3be4d

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Hoymiles User Manual, Three-phase Hybrid Inverter HIT-5L-G3S, HIT-6L-G3S, HIT-8L-G3S, HIT-10L-G3S, HIT-12L-G3S, HIT-15L-G3S, HIT-17L-G3S and HIT-20L-G3S, Region: Global, REV1.1

Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupREV1.1 · 21.88 MB

Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202608/aa06b51275.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
92

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 1f50ff1b55e51b91775cedad567200201eb41b5bb6170dd7b336f31cd9abe570

Hoymiles Three-phase Hybrid Inverter Datasheet, HIT-(5-20)L-G3 and HIT-(5-20)L-G3S, Region: Global, REV1.8

Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupREV1.8 · 0.45 MB

Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202609/57245db193.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: bcae366a9150bf0bf2cab2c7a3ba02dd94e41d8f5474a4926acfbff8dea3be4d

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HIT-12L-G3S

Manufacturer SKU HIT-12L-G3S · Global market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 15
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: 95.7
unit: Unknown
shown: 95.7 %
shown detail: Unknown
state: documented
points: 14.6
ceiling: 15
weight: 15
share: 97.5
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1] [2]
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Hoymiles User Manual, Three-phase Hybrid Inverter HIT-5L-G3S, HIT-6L-G3S, HIT-8L-G3S, HIT-10L-G3S, HIT-12L-G3S, HIT-15L-G3S, HIT-17L-G3S and HIT-20L-G3S, Region: Global, REV1.1 (Hoymiles · manufacturer · REV1.1 · observed Oct 9, 2026)
  2. Hoymiles Three-phase Hybrid Inverter Datasheet, HIT-(5-20)L-G3 and HIT-(5-20)L-G3S, Region: Global, REV1.8 (Hoymiles · manufacturer · REV1.8 · observed Oct 9, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details