Printed as "Weight 64kg" in the Growatt SPF 4000-12000T DVM datasheet (EN 202212), Mechanical specifications, "Weight" row, SPF 8000T DVM and SPF 8000T DVM-US column, captured on September 25, 2026. The DVM and DVM-US datasheets on file print the same figure for this model.
Printed as "2/1" in the Growatt SPF 4000-12000T DVM datasheet (EN 202212), Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF 8000T DVM and SPF 8000T DVM-US column, captured on September 25, 2026. The first figure of the printed pair is the number of MPP trackers. The DVM and DVM-US datasheets on file print the same figure for this model.
Where: Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF 8000T DVM and SPF 8000T DVM-US column
Printed as "Surge Rating 24KW" in the Growatt SPF 4000-12000T DVM datasheet (EN 202212), Inverter output, "Surge Rating" row, SPF 8000T DVM and SPF 8000T DVM-US column, captured on September 25, 2026. The datasheet prints no duration for the surge rating. The DVM and DVM-US datasheets on file print the same figure for this model.
W 380 × H 650 × D 225 mm / W 15 × H 25.6 × D 8.86 in converted
Printed as "380/650/225mm" in the Growatt SPF 4000-12000T DVM datasheet (EN 202212), Dimensions (W / H / D) row, SPF 8000T DVM and SPF 8000T DVM-US column, captured on September 25, 2026.
Where: Dimensions (W / H / D) row, SPF 8000T DVM and SPF 8000T DVM-US column
Printed as "You can choose RS485 c ommunication protocol which is from L01 to L50, and you can also choose CAN communication protocol which is from L51 to L99. Note: You can only use one communication type RS485 or CAN in a tim" in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), captured September 27, 2026. BMS communication via RS485 or CAN, one at a time.
Where: Manual, 2. LCD setting, Program 51 (communication protocol)
Printed as "Maximum PV Array Power 7000W" in the Growatt SPF 4000-12000T DVM datasheet (EN 202212), Solar charger, "Maximum PV Array Power" row, SPF 8000T DVM and SPF 8000T DVM-US column, captured on September 25, 2026. The cell spans the 8000T, 10000T and 12000T columns. The DVM and DVM-US datasheets on file print the same figure for this model.
Where: Solar charger, "Maximum PV Array Power" row, SPF 8000T DVM and SPF 8000T DVM-US column
Printed as "Output Frequency 50Hz/60Hz(+/-0.3 Hz)" in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), Specifications table, captured September 27, 2026. Same for every model.
Where: Manual, Specifications, INVERTER OUTPUT, Output Frequency row
Printed as "Waveform Pure sine wave/ same as input (bypass mode)" in Growatt's SPF 4000-12000T DVM user manual; in bypass mode the output follows the AC input.
Where: User manual Specifications table, INVERTER OUTPUT, Waveform row (one value across the SPF 4000T to 12000T DVM columns), PDF page 32; spec-table row
Printed as "Low frequency inverter 120/240Vac Split Phase output" in the Growatt SPF 4000-12000T DVM datasheet (EN 202212), Feature list row, SPF 8000T DVM and SPF 8000T DVM-US column, captured on September 25, 2026. The specification table also prints "Nominal Output Voltage RMS 104-110-115-120/208-220-230-240VAC(optional)".
Where: Feature list row, SPF 8000T DVM and SPF 8000T DVM-US column
Printed as "Protection Degree | IP20" on page 2 of "Growatt datasheet", row "Protection Degree"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Model Typical Amperage Cable Size Torque 4KW/5KW/6KW 80A 8AWG 1.6~1.8 Nm 8KW/10KW/12KW 120A 8AWG 1.6~1.8 Nm" in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), captured September 27, 2026. Matches the Specifications table's Maximum PV Charge Current row (80A / 120A) for the same model groups.
Printed as "Surge Rating (20ms) 12KW 15KW 18KW 24KW 30KW 36KW" in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), Specifications table. The 20 ms duration in the row heading applies to every model; converted from milliseconds to seconds. Revised on 1 October 2026: The manual prints the surge duration as 20ms; the stored 0.02 s now states its conversion.
Printed as "Transfer Time | 10ms(max)" on page 2 of "Growatt datasheet", row "Transfer Time"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Not printed for this model. The Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), Specifications table, prints "Rated Power 4KW 5KW 6KW 8KW 10KW 12KW", the inverter's rated AC output, and no battery-only output figure; the Growatt SPF 4000-12000T DVM datasheet (EN 202212) prints none either. Revised on 1 October 2026: The manual prints only the inverter's rated AC output (8KW for this model) and no battery-only output figure.
Printed as "Battery Voltage | 48VDC" on page 2 of "Growatt datasheet", row "Battery Voltage"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Rated Power 8KW" in the Growatt SPF 4000-12000T DVM datasheet (EN 202212), Inverter output, "Rated Power" row, SPF 8000T DVM and SPF 8000T DVM-US column, captured on September 25, 2026. The DVM and DVM-US datasheets on file print the same figure for this model.
05 Battery type AGM (Default); Flood; User-Defined; User-Defined 2 (Suitable for lithium battery when no communicating with BMS); Lithium (Only suitable when communicate with BMS); It‟s suggested to connect at least 200Ah capacity battery for 4KW~6KW model and at least 400Ah capacity battery for 8KW~12KW model.
Printed as "05 Battery type AGM (Default)"; "Flood"; "User-Defined"; "User-Defined 2 (Suitable for lithium battery when no communicating with BMS)"; "Lithium (Only suitable when communicate with BMS)"; "It‟s suggested to connect at least 200Ah capacity battery for 4KW~6KW model and at least 400Ah capacity battery for 8KW~12KW model." in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), 2. LCD setting, program 05 Battery type; Battery Connection step 2. Revised on 1 October 2026: The manual lists a "User-Defined 2" setting for lithium batteries without BMS communication, so the record's "lithium only with BMS communication" is not what it prints.
Manual and datasheet give different operating temperature ranges. The Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212) prints "Operation Temperature Range 0°C to 50°C"; the Growatt SPF 4000-12000T DVM datasheet (EN 202212) prints "Operation Temperature Range 0°C to 45°C".
Printed as "Operation Temperature Range 0°C to 50°C" in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), Specifications table; one figure for every model. Revised on 1 October 2026: The installation manual is the primary source and prints 0°C to 50°C; the datasheet's 0°C to 45°C stays beside it.
Where: Manual, Specifications, OPERATING ENVIRONMENT, "Operation Temperature Range" row
Sources
0 to 45 °C
Printed as "Operation Temperature Range | 0°C to 45°C" on page 2 of "Growatt datasheet", row "Operation Temperature Range". No value was taken from another model.
55.58 L* (Calculated from published dimensions)W: 380 × H: 650 × D: 225 mm / W: 15 × H: 25.6 × D: 8.86 inWeight64 kg / 140 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Remedy
Service replacement or service repair under the warranty terms
Printed as "Growatt’s responsibility is limited to service replace and service repair according to the warranty terms & conditions" on Growatt USA's warranty page, captured on September 26, 2026.
Printed as "Country and Region coverage : United States." on Growatt USA's warranty page, service terms item (2), captured on September 26, 2026. The page covers Growatt solar and storage inverters.
Excludes damage from opening the casing without permission, transport, incorrect installation or commissioning, not following the manual, unauthorized modification or repair, incorrect use, insufficient ventilation, ignoring safety regulations and force majeure; a serial number is needed to claim
Printed on Growatt USA's warranty page under Other important notice (2) as a list of exclusions beginning "Breaking the product seal / opening the casing without permission from Growatt", captured on September 26, 2026; item (3) says a serial number must in general be provided to claim.
Where: Other important notice, item (2); Service terms & conditions, item (3)
Date of installation, and no more than 5 and half years from the date of delivery from the Growatt factory
Printed as "... from the date of installation, and no more than 5 and half years from the date of delivery from Growatt factory" on Growatt USA's warranty page, service terms item (3), captured on September 26, 2026. The page defers to the warranty card and any sales contract.
Growatt pays freight for products under warranty, only to the original selling country or region; customers pay customs clearance; Growatt does not offer installation service
Printed as "Growatt takes on the freight cost for products under warranty (Note: this is only to the devices’ original selling country/region)" and "Growatt don’t offer installation service" on Growatt USA's warranty page, captured on September 26, 2026.
Where: Freight cost, item (1); Growatt service commitment, item (4)
Growatt's own user manual, listed on the SPF 4000-12000T DVM product page (us.growatt.com), captured September 27, 2026. Its own Validity page names twelve exact models: SPF 4000/5000/6000/8000/10000/12000T DVM and the same six with a DVM-MPV suffix. Only the plain DVM six are used in this manifest; the DVM-MPV six are not, since the manual's own Specifications table only lists columns for the DVM six.
Archived copies
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Service terms & conditions; Freight cost; Other important notice
Retrieved Sep 25, 2026
Growatt USA's own warranty page, captured on September 26, 2026. Its service terms cover Growatt solar inverters, storage inverters, monitoring devices and software in the United States; it defers to the warranty card and any sales contract, and it does not name individual models or battery products.
Growatt's own US product page for the SPF 4000-12000T DVM-US family, captured as delivered HTML. It establishes what Growatt published on that page on the access date and nothing more: it is a family page, so it is used here only for the product photo and only for the models the page title or the photo's own caption names. No specification, rating or part number was taken from it.
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Growatt Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (SPF DVM / DVM-MPV, EN, 202212)
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].