Charged ReviewsSaved 0Compare 0Login
Growatt
Off-grid inverter

Growatt SPF 6000T DVM-G2

Key specs

Continuous output6 kW
Converted: 6000 W / 1000 = 6 kW
Weight38.5 kg / 84.9 lb converted
Nominal voltage48 V
Efficiency97 %

6 specs not documented yet: communications, ac frequency, pv input current / mppt, surge duration, battery-only output, battery cable size (manual)Help fill in ›

All specifications

Identity

BrandGrowatt · Website
ModelSPF 6000T DVM-G2
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Weight38.5 kg / 84.9 lb converted
Printed as "Net Weight (kgs) 38.5" in the Growatt SPF 6000T DVM-G2 datasheet (EN 202206), Physical, "Net Weight (kgs)" row, SPF6000TDVM-G2 column, captured on September 25, 2026.
Where: Physical, "Net Weight (kgs)" row, SPF6000TDVM-G2 column
[1]
MPPT count1 count
Printed as "1/1" in the Growatt SPF 6000T DVM-G2 datasheet (EN 202206), Solar charger, "Number of Independent MPP Trackers/ Strings Per MPP Tracker" row, SPF6000TDVM-G2 column, captured on September 25, 2026. The first figure of the printed pair is the number of MPP trackers.
Where: Solar charger, "Number of Independent MPP Trackers/ Strings Per MPP Tracker" row, SPF6000TDVM-G2 column
[1]
Peak output18000 VA (surge power)
Printed as "Surge Power 18000VA" in the Growatt SPF 6000T DVM-G2 datasheet (EN 202206), Inverter output, "Surge Power" row, SPF6000TDVM-G2 column, captured on September 25, 2026. The datasheet prints no duration for the surge figure.
Where: Inverter output, "Surge Power" row, SPF6000TDVM-G2 column
[1]
DimensionsW 365 × H 650 × D 247 mm / W 14.4 × H 25.6 × D 9.72 in converted
Printed as "Dimension (D/W/H) 247/365/650mm" in the Growatt SPF 6000T DVM-G2 datasheet (EN 202206), Physical, "Dimension (D/W/H)" row, SPF6000TDVM-G2 column, captured on September 25, 2026. The datasheet orders the figures depth, width, height.
Where: Physical, "Dimension (D/W/H)" row, SPF6000TDVM-G2 column
[1]
CommunicationsUnknown
Not printed for the SPF 6000T DVM-G2: its datasheet (EN 202206) names no communication interface. The earlier RS485 and CAN protocol settings are printed in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), which covers the SPF 6000T DVM, a different edition with its own record. Revised on 1 October 2026: The earlier value came from the manual of the SPF 6000T DVM, a different edition; the DVM-G2 datasheet names no communication interface.
Where: Datasheet pages 1 and 2
[1]
Efficiency97 %
Printed as "Maximum Efficiency | 97%" on page 2 of "Growatt datasheet", row "Maximum Efficiency"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Maximum Efficiency"
[1]
Solar input4.5 kW
Converted: 4500 W / 1000 = 4.5 kW
Printed as "4500W" in the "Maximum PV Array Power" row of the Growatt SPF 6000T DVM-G2 datasheet (EN 202206); converted from watts to kilowatts. Revised on 1 October 2026: The datasheet prints the PV array power in watts; the stored 4.5 kW now states its conversion.
Where: Datasheet page 2, Solar charger, "Maximum PV Array Power" row
Sources
Converted: 4500 W / 1000 = 4.5 kW
[1]
AC frequencyUnknown
Not printed for the SPF 6000T DVM-G2. Its datasheet (EN 202206) prints no output frequency; its AC charger section prints "Frequency Range 50Hz/60Hz (Auto sensing)" for the AC input. The earlier "Output Frequency 50Hz/60Hz (+/-0.3 Hz)" is printed in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), which covers the SPF 6000T DVM, a different edition with its own record. Revised on 1 October 2026: The earlier value came from the manual of the SPF 6000T DVM, a different edition; the DVM-G2 datasheet prints no output frequency.
Where: Datasheet page 2, Inverter output and AC charger
[1]
Max PV charge80 A
Printed as "Maximum Solar Charge Current 80A" in the Growatt SPF 6000T DVM-G2 datasheet (EN 202206).
Where: Datasheet page 2, Solar charger, "Maximum Solar Charge Current" row
[1]
Output waveformPure sine wave
Printed as "Pure sine wave" in the Waveform row of Growatt's SPF 6000T DVM-G2 datasheet (read from the rendered table; the text layer separates label and value).
Where: Datasheet page 2, INVERTER OUTPUT, Waveform row (single SPF 6000T DVM-G2 column); spec-table row, label and value paired from the rendered table because the text layer lists the labels before the values
[1]
AC configuration104-110-115-120/208-220-230-240VAC (optional), battery mode
Printed as "104-110-115-120/208-220-230-240VAC(optional)" in the Growatt SPF 6000T DVM-G2 datasheet (EN 202206), Inverter output, "AC Voltage Regulation (Battery Mode)" row, SPF6000TDVM-G2 column, captured on September 25, 2026.
Where: Inverter output, "AC Voltage Regulation (Battery Mode)" row, SPF6000TDVM-G2 column
[1]
Enclosure ratingIP20
Printed as "Protection Degree | IP20" on page 2 of "Growatt datasheet", row "Protection Degree"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Protection Degree"
[1]
Max PV currentUnknown
Not printed for the SPF 6000T DVM-G2: its datasheet (EN 202206) prints no PV input current; it prints "Maximum Solar Charge Current 80A", the battery charge current, recorded separately. The earlier PV connection figure is printed in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), which covers the SPF 6000T DVM, a different edition with its own record. Revised on 1 October 2026: The earlier value came from the manual of the SPF 6000T DVM, a different edition; the DVM-G2 datasheet prints no PV input current.
Where: Datasheet page 2, Solar charger
[1]
Surge duration sUnknown
Not printed for the SPF 6000T DVM-G2: its datasheet (EN 202206) prints "Surge Power 18000VA" with no duration. The earlier 20 ms is printed in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), which covers the SPF 6000T DVM, a different edition with its own record. Revised on 1 October 2026: The earlier value came from the manual of the SPF 6000T DVM, a different edition; the DVM-G2 datasheet prints no surge duration.
Where: Datasheet page 2, Inverter output, "Surge Power" row
[1]
Transfer time10 ms
Printed as "Transfer Time | 10ms" on page 2 of "Growatt datasheet", row "Transfer Time"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Transfer Time"
[1]
Battery outputUnknown
Not printed for the SPF 6000T DVM-G2. Its datasheet (EN 202206) prints "Rated Power 6000VA / 6000W", the inverter's rated AC output, and no battery-only output figure. The earlier value came from the rated power row of the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), which covers the SPF 6000T DVM, a different edition with its own record. Revised on 1 October 2026: No battery-only output figure is printed for this edition; the earlier value was the rated AC output from another edition's manual.
Where: Datasheet page 2, Inverter output
[1]
Battery wire sizeUnknown
Not printed for the SPF 6000T DVM-G2: its datasheet (EN 202206) gives no battery cable size. The earlier value is printed in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), which covers the SPF 6000T DVM, a different edition with its own record. Revised on 1 October 2026: The earlier value came from the manual of the SPF 6000T DVM, a different edition; the DVM-G2 datasheet prints no cable size.
Where: Datasheet pages 1 and 2
[1]
Nominal voltage48 V
Printed as "Battery Voltage | 48VDC" on page 2 of "Growatt datasheet", row "Battery Voltage"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Battery Voltage"
[1]
Continuous output6 kW
Converted: 6000 W / 1000 = 6 kW
Printed as "6000VA / 6000W" in the "Rated Power" row of the Growatt SPF 6000T DVM-G2 datasheet (EN 202206); converted from watts to kilowatts. Revised on 1 October 2026: The datasheet prints the rated power in watts; the stored 6 kW now states its conversion.
Where: Datasheet page 2, Inverter output, "Rated Power" row
Sources
Converted: 6000 W / 1000 = 6 kW
[1]
Battery compatibilityLithium/Lead-acid
Printed as "Battery Type Lithium/Lead-acid" in the Growatt SPF 6000T DVM-G2 datasheet (EN 202206). The earlier value, with its battery-type program settings, was printed in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), which covers the SPF 6000T DVM, a different edition with its own record. Revised on 1 October 2026: The earlier value came from the manual of the SPF 6000T DVM, a different edition; the SPF 6000T DVM-G2 datasheet prints the battery type itself.
Where: Datasheet page 2, "Battery Type" row
[1]
Operating temperature-20 to 50 °C / -4 to 122 °F converted
Printed as "Operating Temperature | - 20°C - 50°C" on page 2 of "Growatt datasheet", row "Operating Temperature"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Operating Temperature"
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
6 kW
Battery voltage
48 V
Solar input
4.5 kWMPPT trackers 1
AC output
104-110-115-120/208-220-230-240VAC (optional), battery mode
Warranty
Not stated
Size
58.6 L* (Calculated from published dimensions)W: 365 × H: 650 × D: 247 mm / W: 14.4 × H: 25.6 × D: 9.72 inWeight 38.5 kg / 84.9 lb

Evidence score

Research pending0% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
RemedyService replacement or service repair under the warranty terms
Printed as "Growatt’s responsibility is limited to service replace and service repair according to the warranty terms & conditions" on Growatt USA's warranty page, captured on September 26, 2026.
Where: Other important notice, item (3)
[2]
TerritoryUnited States
Printed as "Country and Region coverage : United States." on Growatt USA's warranty page, service terms item (2), captured on September 26, 2026. The page covers Growatt solar and storage inverters.
Where: Service terms & conditions, item (2)
[2]
ConditionsExcludes damage from opening the casing without permission, transport, incorrect installation or commissioning, not following the manual, unauthorized modification or repair, incorrect use, insufficient ventilation, ignoring safety regulations and force majeure; a serial number is needed to claim
Printed on Growatt USA's warranty page under Other important notice (2) as a list of exclusions beginning "Breaking the product seal / opening the casing without permission from Growatt", captured on September 26, 2026; item (3) says a serial number must in general be provided to claim.
Where: Other important notice, item (2); Service terms & conditions, item (3)
[2]
Start basisDate of installation, and no more than 5 and half years from the date of delivery from the Growatt factory
Printed as "... from the date of installation, and no more than 5 and half years from the date of delivery from Growatt factory" on Growatt USA's warranty page, service terms item (3), captured on September 26, 2026. The page defers to the warranty card and any sales contract.
Where: Service terms & conditions, item (3)
[2]
Labor and shippingGrowatt pays freight for products under warranty, only to the original selling country or region; customers pay customs clearance; Growatt does not offer installation service
Printed as "Growatt takes on the freight cost for products under warranty (Note: this is only to the devices’ original selling country/region)" and "Growatt don’t offer installation service" on Growatt USA's warranty page, captured on September 26, 2026.
Where: Freight cost, item (1); Growatt service commitment, item (4)
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Growatt Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (SPF DVM / DVM-MPV, EN, 202212)Official · Growatt · Official instruction manual · December 2022 · PDF
    Source details
    Revision
    202212
    Revision date
    December 2022

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-27.

    Location: 5 Battery Connection; 10 PV Connection; Lithium battery connection; Specifications

    Retrieved Sep 27, 2026

    Growatt's own user manual, listed on the SPF 4000-12000T DVM product page (us.growatt.com), captured September 27, 2026. Its own Validity page names twelve exact models: SPF 4000/5000/6000/8000/10000/12000T DVM and the same six with a DVM-MPV suffix. Only the plain DVM six are used in this manifest; the DVM-MPV six are not, since the manual's own Specifications table only lists columns for the DVM six.

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup202212 · 2.68 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000_DVM-MPV_User_Manual_EN_202212.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2022-12

    Embedded creation date
    Embedded modification date
    Pages
    33

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 006ac6393532d08826b986fe196385fb2790f87a708b23596fa512d1e6eb5855

    Open
  • Datasheets

  • Growatt datasheetOfficial · Growatt · Official datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF page 2

    Retrieved Sep 15, 2026

    SHA-256: 522f5b1f779b456b532500dd3b21776033646571a8785ac1f8485ab1680d093c

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 4.13 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000T_DVM-US_Datasheet_EN_202212.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 522f5b1f779b456b532500dd3b21776033646571a8785ac1f8485ab1680d093c

    Open
  • Warranty

  • Growatt USA warranty page: Service terms & conditionsOfficial · Growatt · Official warranty · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: Service terms & conditions; Freight cost; Other important notice

    Retrieved Sep 25, 2026

    Growatt USA's own warranty page, captured on September 26, 2026. Its service terms cover Growatt solar inverters, storage inverters, monitoring devices and software in the United States; it defers to the warranty card and any sales contract, and it does not name individual models or battery products.

    Open
  • Other documents

  • Growatt product page: SPF 4000-12000T DVM-USOfficial · Growatt · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured with a plain HTTPS GET and a browser user agent.

    Location: SPF 4000-12000T DVM-US | Split Phase Off-Grid | Growatt

    Retrieved Sep 19, 2026

    Growatt's own US product page for the SPF 4000-12000T DVM-US family, captured as delivered HTML. It establishes what Growatt published on that page on the access date and nothing more: it is a family page, so it is used here only for the product photo and only for the models the page title or the photo's own caption names. No specification, rating or part number was taken from it.

    Open

Archive and older revisions

Archive and older revisions3

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • Growatt datasheetOfficial · Growatt · Official datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF page 2

    Retrieved Sep 15, 2026

    SHA-256: d7601347ee704004b74cb16748e1940f28cfaefedea8c141f69b5ecc94413249

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.54 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000T_DVM-MPV_Datasheet_EN_202212.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: d7601347ee704004b74cb16748e1940f28cfaefedea8c141f69b5ecc94413249

    Open
  • Growatt datasheetOfficial · Growatt · Official datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF page 2

    Retrieved Sep 15, 2026

    SHA-256: 31fb8555d95a71ef658392f9b5cca417b17a65018a0b7268f1e33981b83220ee

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.44 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_6000T_DVM-G2_Datasheet_EN_202206.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 31fb8555d95a71ef658392f9b5cca417b17a65018a0b7268f1e33981b83220ee

    Open
  • Growatt datasheetOfficial · Growatt · Official datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF page 2

    Retrieved Sep 15, 2026

    SHA-256: 1dee71f6e8070683361317487f655f53959592932d8c9498c02522e86dc7a969

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 3.82 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000T_DVM_Datasheet_EN_202212.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 1dee71f6e8070683361317487f655f53959592932d8c9498c02522e86dc7a969

    Open

Archived documents

Growatt datasheet

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.44 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_6000T_DVM-G2_Datasheet_EN_202206.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 31fb8555d95a71ef658392f9b5cca417b17a65018a0b7268f1e33981b83220ee

Growatt datasheet

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 3.82 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000T_DVM_Datasheet_EN_202212.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 1dee71f6e8070683361317487f655f53959592932d8c9498c02522e86dc7a969

Growatt datasheet

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.54 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000_DVM-MPV_Datasheet_EN_202212.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d7601347ee704004b74cb16748e1940f28cfaefedea8c141f69b5ecc94413249

Growatt datasheet

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 4.13 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000T_DVM-US_Datasheet_EN_202212.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 522f5b1f779b456b532500dd3b21776033646571a8785ac1f8485ab1680d093c

Growatt Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (SPF DVM / DVM-MPV, EN, 202212)

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup202212 · 2.68 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000_DVM-MPV_User_Manual_EN_202212.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2022-12

Embedded creation date
Embedded modification date
Pages
33

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 006ac6393532d08826b986fe196385fb2790f87a708b23596fa512d1e6eb5855

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SPF 6000T DVM-G2
Published model / SKU
SPF 6000T

Earlier model name on this record, kept so a search for it still finds the record.

[1]

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 0
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Growatt datasheet (Growatt · manufacturer · observed Sep 15, 2026)
  2. Growatt USA warranty page: Service terms & conditions (Growatt · manufacturer · observed Sep 25, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details