Charged ReviewsSaved 0Compare 0Login
Growatt SPF 3000T HVM-G2
Growatt
Off-grid inverter

Growatt SPF 3000T HVM-G2

Key specs

Continuous output3 kW
Weight27 kg / 60 lb converted
Nominal voltage48 V
Efficiency97 %
AC frequency50Hz

1 spec not documented yet: battery-only outputHelp fill in ›

All specifications

Identity

BrandGrowatt · Website
ModelSPF 3000T HVM-G2
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
CoolingFan assisted cooling
Printed as "Operating Temperature Range -20°C to 50°C (fan assisted cooling)" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 4, captured on September 26, 2026.
Where: PDF page 15 (printed page 27), Table 4
[1]
Weight27 kg / 60 lb converted
Printed as "Net Weight 27kg" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Physical, "Net Weight" row, SPF3000THVM-G2 column, captured on September 25, 2026.
Where: Physical, "Net Weight" row, SPF3000THVM-G2 column
[2]
MPPT count1 count
Printed as "1/1" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF3000THVM-G2 column, captured on September 25, 2026. The first figure of the printed pair is the number of MPP trackers.
Where: Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF3000THVM-G2 column
[2]
Peak output9 kW (surge rating)
Printed as "Surge Rating 9KW" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Inverter output, "Surge Rating" row, SPF3000THVM-G2 column, captured on September 25, 2026. The datasheet prints no duration for the surge rating.
Where: Inverter output, "Surge Rating" row, SPF3000THVM-G2 column
[2]
Max charge40 A
Printed as "Max. Charging Current | 40A | 60A" on page 2 of "Growatt datasheet", row "Max. Charging Current", column "SPF3000THVM-G2" of header "Datasheet | SPF3000THVM-G2 | SPF6000THVM-G2"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Max. Charging Current"
[2]
DimensionsW 300 × H 550 × D 225 mm / W 11.8 × H 21.7 × D 8.86 in converted
Printed as "Dimensions (W/H/D) 300/550/225mm" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Physical, "Dimensions (W/H/D)" row, SPF3000THVM-G2 column, captured on September 25, 2026.
Where: Physical, "Dimensions (W/H/D)" row, SPF3000THVM-G2 column
[2]
CommunicationsRS485; CAN
Printed as "BMS communication port(RS485 or CAN)" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Lithium Battery Connection, captured on September 26, 2026.
Where: PDF page 5 (printed page 6)
[1]
Efficiency97 %
Printed as "Maximum Efficiency | 97%" on page 2 of "Growatt datasheet", row "Maximum Efficiency"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Maximum Efficiency"
[2]
Solar array4.5 kW
Converted: 4,500 W / 1000 = 4.5 kW
Printed as "Max. Recommended PV Power 4500W" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Solar charger, "Max. Recommended PV Power" row, SPF3000THVM-G2 column, captured on September 25, 2026. The cell spans both model columns.
Where: Solar charger, "Max. Recommended PV Power" row, SPF3000THVM-G2 column
Sources
Converted: 4,500 W / 1000 = 4.5 kW
[2]
AC frequency50Hz
Printed as "Output Frequency 50Hz" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured on September 26, 2026.
Where: PDF page 15 (printed page 26), Table 2 Inverter Mode Specifications
[1]
Max AC charge40 A
Printed as "Max. AC Charging Current 40Amp(@VI/P=230Vac)" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured on September 26, 2026.
Where: PDF page 15 (printed page 27), Table 3 Charge Mode Specifications
[1]
Output waveformPure sine wave
Printed as "Waveform Pure sine wave/ same as input (bypass mode)" in Growatt's SPF 3000T/6000T HVM-G2 datasheet; in bypass mode the output follows the AC input.
Where: Datasheet page 2, Inverter Output, Waveform row (one value across the SPF 3000T and 6000T HVM-G2 columns); spec-table row
[2]
AC configuration208-220-230-240VAC (optional)
Printed as "Nominal Output Voltage RMS 208-220-230-240VAC(optional)" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Inverter output, "Nominal Output Voltage RMS" row, SPF3000THVM-G2 column, captured on September 25, 2026.
Where: Inverter output, "Nominal Output Voltage RMS" row, SPF3000THVM-G2 column
[2]
Enclosure ratingIP20
Printed as "Protection Degree | IP20" on page 2 of "Growatt datasheet", row "Protection Degree"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Protection Degree"
[2]
Max PV current80 A
Printed as "Max. PV Charging Current 80A" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured September 27, 2026.
Where: PDF page 15 (printed page 27), Table 3 Charge Mode Specifications, MPPT Solar Charging Mode, Max. PV Charging Current row
[1]
Max PV voltage250 V
Printed as "Maximum PV Array Open Circuit Voltage | 250V" on page 2 of "Growatt datasheet", row "Maximum PV Array Open Circuit Voltage"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Maximum PV Array Open Circuit Voltage"
[2]
Transfer time10 ms
Printed as "Transfer Time | 10ms" on page 2 of "Growatt datasheet", row "Transfer Time"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Transfer Time"
[2]
Battery outputUnknown
Not printed for this model. The Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2 Inverter Mode Specifications, prints "Rated Output Power 3KVA / 3KW", the inverter's rated AC output, and no battery-only output figure; the SPF 3000-6000T HVM-G2 datasheet (EN 202305) prints none either. Revised on 1 October 2026: The manual prints only the inverter's rated AC output (3KVA / 3KW) and no battery-only output figure.
Where: PDF page 14 (printed page 26), Table 2 Inverter Mode Specifications
[1]
Battery wire size1 * 4 AWG
Printed as "SPF 3000T HVM-G2 1 * 4 AWG 2-3 Nm" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Battery Connection, captured on September 26, 2026.
Where: PDF page 4 (printed page 5), Recommended battery cable and terminal size
[1]
Nominal voltage48 V
Printed as "Battery Voltage | 48VDC" on page 2 of "Growatt datasheet", row "Battery Voltage"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Battery Voltage"
[2]
Grid passthrough30 A
Printed as "Input Current Max 30A" (Table 1) and "Max. AC input current is 30A. If AC input current is over 30A, AC charge current will drop down to zero. Then the system will cut off output in 10 seconds if the AC input is continued to be over 30A." (AC Input/Output Connection) in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), captured September 27, 2026.
Where: PDF pages 6-7 (printed pages 8-9), Table 1 Line Mode Specifications (Input Current row) and AC Input/Output Connection note
[1]
Idle consumption20 W
Printed as "<20W"; the figure is an upper bound.
Printed as "No Load Power Consumption <20W" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured September 27, 2026. The unit is operating with no connected load, not powered off.
Where: PDF page 14 (printed page 26), Table 2 Inverter Mode Specifications, No Load Power Consumption row
[1]
Maximum AC input30 A
Printed as "Input Current Max 30A" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 1, captured on September 26, 2026.
Where: PDF page 14 (printed page 25), Table 1 Line Mode Specifications
[1]
Terminal torque2 to 3 N·m
Printed as "SPF 3000T HVM-G2 1 * 4 AWG 2-3 Nm" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Battery Connection, captured on September 26, 2026. Battery terminals.
Where: PDF page 4 (printed page 5)
[1]
Continuous output3 kW
Printed as "Rated Power | 3KW | 6KW" on page 2 of "Growatt datasheet", row "Rated Power", column "SPF3000THVM-G2" of header "Datasheet | SPF3000THVM-G2 | SPF6000THVM-G2"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Rated Power"
[2]
Battery compatibility05 Battery type AGM (default); Flooded; Lithium (only suitable when communicated with BMS); User-Defined; User-Defined 2 (suitable when lithium battery without BMS communication); you are allowed to use the lithium battery only which we have configured
Printed as "05 Battery type AGM (default)"; "Flooded"; "Lithium (only suitable when communicated with BMS)"; "User-Defined"; "User-Defined 2 (suitable when lithium battery without BMS communication)"; "you are allowed to use the lithium battery only which we have configured" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), program 05 Battery type and Lithium Battery Connection. Revised on 1 October 2026: The manual lists a "User-Defined 2" setting for lithium batteries without BMS communication, so the record's "lithium only with BMS communication" is not what it prints.
Where: Lithium Battery Connection; Lithium battery communication and setting, program 05 Battery type
[1]
Storage temperature-40 to 60 °C / -40 to 140 °F converted
Printed as "Storage temperature -40°C~ 60°C" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 4, captured on September 26, 2026.
Where: PDF page 15 (printed page 27), Table 4 General Specifications
[1]
Operating temperature-20 to 50 °C / -4 to 122 °F converted
Printed as "Operation Temperature Range | -20°C to 50°C" on page 2 of "Growatt datasheet", row "Operation Temperature Range"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Operation Temperature Range"
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
3 kW
Battery voltage
48 V
Solar input
4.5 kWMPPT trackers 1
AC output
208-220-230-240VAC (optional)
Warranty
Not stated
Size
37.12 L* (Calculated from published dimensions)W: 300 × H: 550 × D: 225 mm / W: 11.8 × H: 21.7 × D: 8.86 inWeight 27 kg / 60 lb

Evidence score

4/100Missing details10% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Idle consumption20 W4.0 / 10.0

20 against 8 W, the lowest documented for an inverter in the 1.5 to 3.5 kW output band (printed by the maker): Victron Energy Inverter 12/2000 Smart

Printed as "No Load Power Consumption <20W" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured September 27, 2026. The unit is operating with no connected load, not powered off. Printed as a bound: less than 20 W, as printed.

[1]

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
RemedyService replacement or service repair under the warranty terms
Printed as "Growatt’s responsibility is limited to service replace and service repair according to the warranty terms & conditions" on Growatt USA's warranty page, captured on September 26, 2026.
Where: Other important notice, item (3)
[3]
TerritoryUnited States
Printed as "Country and Region coverage : United States." on Growatt USA's warranty page, service terms item (2), captured on September 26, 2026. The page covers Growatt solar and storage inverters.
Where: Service terms & conditions, item (2)
[3]
ConditionsExcludes damage from opening the casing without permission, transport, incorrect installation or commissioning, not following the manual, unauthorized modification or repair, incorrect use, insufficient ventilation, ignoring safety regulations and force majeure; a serial number is needed to claim
Printed on Growatt USA's warranty page under Other important notice (2) as a list of exclusions beginning "Breaking the product seal / opening the casing without permission from Growatt", captured on September 26, 2026; item (3) says a serial number must in general be provided to claim.
Where: Other important notice, item (2); Service terms & conditions, item (3)
[3]
Start basisDate of installation, and no more than 5 and half years from the date of delivery from the Growatt factory
Printed as "... from the date of installation, and no more than 5 and half years from the date of delivery from Growatt factory" on Growatt USA's warranty page, service terms item (3), captured on September 26, 2026. The page defers to the warranty card and any sales contract.
Where: Service terms & conditions, item (3)
[3]
Labor and shippingGrowatt pays freight for products under warranty, only to the original selling country or region; customers pay customs clearance; Growatt does not offer installation service
Printed as "Growatt takes on the freight cost for products under warranty (Note: this is only to the devices’ original selling country/region)" and "Growatt don’t offer installation service" on Growatt USA's warranty page, captured on September 26, 2026.
Where: Freight cost, item (1); Growatt service commitment, item (4)
[3]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Growatt Off Grid Solar Inverter SPF 3000T HVM-G2 User Manual (Version 1.0)Official · Growatt · Official user manual · May 2023 · PDF
    Source details
    Revision
    Version 1.0
    Revision date
    May 2023

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: Specifications tables; battery connection

    Retrieved Sep 25, 2026

    Growatt's own user manual for the SPF 3000T HVM-G2, listed on us.growatt.com Download, Manual & Quick Guide, captured on September 26, 2026. Image-only document with no text layer: facts were read from the rendered pages and cite the PDF page; each PDF page shows two printed pages. It covers only the 3000T model.

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupVersion 1.0 · 15.52 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3000T_HVM-G2_User_Manual_EN_202305.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2023-05

    Embedded creation date
    Embedded modification date
    Pages
    15

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 4e8109e2bb7dc6fc59cb965f26997b8f0a1bf04a8f3ca2efa006ee4aee8cf96c

    Open
  • Datasheets

  • Growatt datasheetOfficial · Growatt · Official datasheet · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF page 2

    Retrieved Sep 15, 2026

    SHA-256: 20f5ba5d99cb3bfad585e07092ab63583af2232b6a8986ac026ad612db774b23

    Archived copies

    Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.46 MB

    Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3000-6000T_HVM-G2_Datasheet_EN_202305.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 20f5ba5d99cb3bfad585e07092ab63583af2232b6a8986ac026ad612db774b23

    Open
  • Warranty

  • Growatt USA warranty page: Service terms & conditionsOfficial · Growatt · Official warranty · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: Service terms & conditions; Freight cost; Other important notice

    Retrieved Sep 25, 2026

    Growatt USA's own warranty page, captured on September 26, 2026. Its service terms cover Growatt solar inverters, storage inverters, monitoring devices and software in the United States; it defers to the warranty card and any sales contract, and it does not name individual models or battery products.

    Open
  • Other documents

  • Growatt product page: SPF 3000-6000T HVM-G2Official · Growatt · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Product image and download list

    Retrieved Sep 24, 2026

    Growatt's own US product page for the SPF 3000-6000T HVM-G2 family on us.growatt.com, captured on September 25, 2026. Used here only for the product image it publishes and the documents it links; no specification is taken from the page.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Growatt datasheet

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.46 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3000-6000T_HVM-G2_Datasheet_EN_202305.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 20f5ba5d99cb3bfad585e07092ab63583af2232b6a8986ac026ad612db774b23

Growatt Off Grid Solar Inverter SPF 3000T HVM-G2 User Manual (Version 1.0)

Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupVersion 1.0 · 15.52 MB

Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_3000T_HVM-G2_User_Manual_EN_202305.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2023-05

Embedded creation date
Embedded modification date
Pages
15

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 4e8109e2bb7dc6fc59cb965f26997b8f0a1bf04a8f3ca2efa006ee4aee8cf96c

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SPF 3000T HVM-G2
Published model / SKU
SPF 3000T HV

Earlier model name on this record, kept so a search for it still finds the record.

[2]

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 10
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 20
unit: Unknown
shown: 20 W
shown detail: Unknown
state: documented
points: 4
ceiling: 10
weight: 10
share: 40
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Printed as a bound: less than 20 W, as printed.
display note: Unknown
Sources: [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Growatt Off Grid Solar Inverter SPF 3000T HVM-G2 User Manual (Version 1.0) (Growatt · manufacturer · Version 1.0 · observed Sep 25, 2026)
  2. Growatt datasheet (Growatt · manufacturer · observed Sep 15, 2026)
  3. Growatt USA warranty page: Service terms & conditions (Growatt · manufacturer · observed Sep 25, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details