Printed as "Operating Temperature Range -20°C to 50°C (fan assisted cooling)" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 4, captured on September 26, 2026.
Printed as "Net Weight 27kg" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Physical, "Net Weight" row, SPF3000THVM-G2 column, captured on September 25, 2026.
Printed as "1/1" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF3000THVM-G2 column, captured on September 25, 2026. The first figure of the printed pair is the number of MPP trackers.
Where: Solar charger, "Number of independent MPP trackers/ strings per MPP tracker" row, SPF3000THVM-G2 column
Printed as "Surge Rating 9KW" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Inverter output, "Surge Rating" row, SPF3000THVM-G2 column, captured on September 25, 2026. The datasheet prints no duration for the surge rating.
Printed as "Max. Charging Current | 40A | 60A" on page 2 of "Growatt datasheet", row "Max. Charging Current", column "SPF3000THVM-G2" of header "Datasheet | SPF3000THVM-G2 | SPF6000THVM-G2"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
W 300 × H 550 × D 225 mm / W 11.8 × H 21.7 × D 8.86 in converted
Printed as "Dimensions (W/H/D) 300/550/225mm" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Physical, "Dimensions (W/H/D)" row, SPF3000THVM-G2 column, captured on September 25, 2026.
Printed as "BMS communication port(RS485 or CAN)" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Lithium Battery Connection, captured on September 26, 2026.
Printed as "Maximum Efficiency | 97%" on page 2 of "Growatt datasheet", row "Maximum Efficiency"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Max. Recommended PV Power 4500W" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Solar charger, "Max. Recommended PV Power" row, SPF3000THVM-G2 column, captured on September 25, 2026. The cell spans both model columns.
Where: Solar charger, "Max. Recommended PV Power" row, SPF3000THVM-G2 column
Printed as "Output Frequency 50Hz" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured on September 26, 2026.
Printed as "Max. AC Charging Current 40Amp(@VI/P=230Vac)" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured on September 26, 2026.
Printed as "Waveform Pure sine wave/ same as input (bypass mode)" in Growatt's SPF 3000T/6000T HVM-G2 datasheet; in bypass mode the output follows the AC input.
Where: Datasheet page 2, Inverter Output, Waveform row (one value across the SPF 3000T and 6000T HVM-G2 columns); spec-table row
Printed as "Nominal Output Voltage RMS 208-220-230-240VAC(optional)" in the Growatt SPF 3000-6000T HVM-G2 datasheet (EN 202305), Inverter output, "Nominal Output Voltage RMS" row, SPF3000THVM-G2 column, captured on September 25, 2026.
Where: Inverter output, "Nominal Output Voltage RMS" row, SPF3000THVM-G2 column
Printed as "Protection Degree | IP20" on page 2 of "Growatt datasheet", row "Protection Degree"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Max. PV Charging Current 80A" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 3, captured September 27, 2026.
Where: PDF page 15 (printed page 27), Table 3 Charge Mode Specifications, MPPT Solar Charging Mode, Max. PV Charging Current row
Printed as "Maximum PV Array Open Circuit Voltage | 250V" on page 2 of "Growatt datasheet", row "Maximum PV Array Open Circuit Voltage"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Transfer Time | 10ms" on page 2 of "Growatt datasheet", row "Transfer Time"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Not printed for this model. The Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2 Inverter Mode Specifications, prints "Rated Output Power 3KVA / 3KW", the inverter's rated AC output, and no battery-only output figure; the SPF 3000-6000T HVM-G2 datasheet (EN 202305) prints none either. Revised on 1 October 2026: The manual prints only the inverter's rated AC output (3KVA / 3KW) and no battery-only output figure.
Printed as "SPF 3000T HVM-G2 1 * 4 AWG 2-3 Nm" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Battery Connection, captured on September 26, 2026.
Where: PDF page 4 (printed page 5), Recommended battery cable and terminal size
Printed as "Battery Voltage | 48VDC" on page 2 of "Growatt datasheet", row "Battery Voltage"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Input Current Max 30A" (Table 1) and "Max. AC input current is 30A. If AC input current is over 30A, AC charge current will drop down to zero. Then the system will cut off output in 10 seconds if the AC input is continued to be over 30A." (AC Input/Output Connection) in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), captured September 27, 2026.
Where: PDF pages 6-7 (printed pages 8-9), Table 1 Line Mode Specifications (Input Current row) and AC Input/Output Connection note
Printed as "No Load Power Consumption <20W" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured September 27, 2026. The unit is operating with no connected load, not powered off.
Where: PDF page 14 (printed page 26), Table 2 Inverter Mode Specifications, No Load Power Consumption row
Printed as "Input Current Max 30A" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 1, captured on September 26, 2026.
Where: PDF page 14 (printed page 25), Table 1 Line Mode Specifications
Printed as "SPF 3000T HVM-G2 1 * 4 AWG 2-3 Nm" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Battery Connection, captured on September 26, 2026. Battery terminals.
Printed as "Rated Power | 3KW | 6KW" on page 2 of "Growatt datasheet", row "Rated Power", column "SPF3000THVM-G2" of header "Datasheet | SPF3000THVM-G2 | SPF6000THVM-G2"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
05 Battery type AGM (default); Flooded; Lithium (only suitable when communicated with BMS); User-Defined; User-Defined 2 (suitable when lithium battery without BMS communication); you are allowed to use the lithium battery only which we have configured
Printed as "05 Battery type AGM (default)"; "Flooded"; "Lithium (only suitable when communicated with BMS)"; "User-Defined"; "User-Defined 2 (suitable when lithium battery without BMS communication)"; "you are allowed to use the lithium battery only which we have configured" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), program 05 Battery type and Lithium Battery Connection. Revised on 1 October 2026: The manual lists a "User-Defined 2" setting for lithium batteries without BMS communication, so the record's "lithium only with BMS communication" is not what it prints.
Where: Lithium Battery Connection; Lithium battery communication and setting, program 05 Battery type
Printed as "Storage temperature -40°C~ 60°C" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 4, captured on September 26, 2026.
Where: PDF page 15 (printed page 27), Table 4 General Specifications
Printed as "Operation Temperature Range | -20°C to 50°C" on page 2 of "Growatt datasheet", row "Operation Temperature Range"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Where: datasheet page 2, row "Operation Temperature Range"
37.12 L* (Calculated from published dimensions)W: 300 × H: 550 × D: 225 mm / W: 11.8 × H: 21.7 × D: 8.86 inWeight27 kg / 60 lb
Evidence score
4/100Missing details10% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Idle consumption20 W4.0 / 10.0
20 against 8 W, the lowest documented for an inverter in the 1.5 to 3.5 kW output band (printed by the maker): Victron Energy Inverter 12/2000 Smart
Printed as "No Load Power Consumption <20W" in the Growatt SPF 3000T HVM-G2 User Manual (Version 1.0, image-only document, read from the rendered pages), Table 2, captured September 27, 2026. The unit is operating with no connected load, not powered off. Printed as a bound: less than 20 W, as printed.
Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Remedy
Service replacement or service repair under the warranty terms
Printed as "Growatt’s responsibility is limited to service replace and service repair according to the warranty terms & conditions" on Growatt USA's warranty page, captured on September 26, 2026.
Printed as "Country and Region coverage : United States." on Growatt USA's warranty page, service terms item (2), captured on September 26, 2026. The page covers Growatt solar and storage inverters.
Excludes damage from opening the casing without permission, transport, incorrect installation or commissioning, not following the manual, unauthorized modification or repair, incorrect use, insufficient ventilation, ignoring safety regulations and force majeure; a serial number is needed to claim
Printed on Growatt USA's warranty page under Other important notice (2) as a list of exclusions beginning "Breaking the product seal / opening the casing without permission from Growatt", captured on September 26, 2026; item (3) says a serial number must in general be provided to claim.
Where: Other important notice, item (2); Service terms & conditions, item (3)
Date of installation, and no more than 5 and half years from the date of delivery from the Growatt factory
Printed as "... from the date of installation, and no more than 5 and half years from the date of delivery from Growatt factory" on Growatt USA's warranty page, service terms item (3), captured on September 26, 2026. The page defers to the warranty card and any sales contract.
Growatt pays freight for products under warranty, only to the original selling country or region; customers pay customs clearance; Growatt does not offer installation service
Printed as "Growatt takes on the freight cost for products under warranty (Note: this is only to the devices’ original selling country/region)" and "Growatt don’t offer installation service" on Growatt USA's warranty page, captured on September 26, 2026.
Where: Freight cost, item (1); Growatt service commitment, item (4)
Growatt's own user manual for the SPF 3000T HVM-G2, listed on us.growatt.com Download, Manual & Quick Guide, captured on September 26, 2026. Image-only document with no text layer: facts were read from the rendered pages and cite the PDF page; each PDF page shows two printed pages. It covers only the 3000T model.
Archived copies
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Service terms & conditions; Freight cost; Other important notice
Retrieved Sep 25, 2026
Growatt USA's own warranty page, captured on September 26, 2026. Its service terms cover Growatt solar inverters, storage inverters, monitoring devices and software in the United States; it defers to the warranty card and any sales contract, and it does not name individual models or battery products.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Product image and download list
Retrieved Sep 24, 2026
Growatt's own US product page for the SPF 3000-6000T HVM-G2 family on us.growatt.com, captured on September 25, 2026. Used here only for the product image it publishes and the documents it links; no specification is taken from the page.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Growatt datasheet
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Growatt Off Grid Solar Inverter SPF 3000T HVM-G2 User Manual (Version 1.0)
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].