Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

GoodWe GW50K-ET-10

Brand
GoodWe
Model
GW50K-ET-10
SKU / part number
?
Category
Inverters

chargedreviews.com/inverters/goodwe-gw50k-et-10

AC output

Continuous output
50 kW [1]
Peak output
60,000 VA for 60 s; 75,000 VA for 10 s (without grid) [1]
AC configuration
Three-phase [2]
AC output voltage
380 / 400 V, 3L / N / PE [1]
AC frequency
50 / 60 Hz [1]
Grid pass-through
?
Maximum output per leg
?

Battery

Battery voltage
500 V [3] [1]
Battery voltage range
200 to 800 V [3] [1]
Maximum charge current
100 A [3] [1]
Maximum discharge current
100 A [3] [1]
Battery-only output
55 kW [3] [1]
Maximum grid charging
?
Compatible batteries / BMS
?

PV input

PV array limit (connected)
?
PV input limit (converted)
75 kW [1]
Maximum PV voltage (Voc)
1,000 V [3] [1]
MPPT voltage range
165 to 850 V [3] [1]
MPPT trackers
4 [3] [1]
String inputs per MPPT
2 [3] [1]
PV current per MPPT
42 / 32 / 42 / 32 A [1]
PV short-circuit current
55 / 42 / 55 / 42 A [1]
PV startup voltage
200 V [3] [1]

Efficiency and modes

Peak efficiency
98.1 % [3] [1]
CEC weighted efficiency
97.5 % [3] [1]
Battery conversion efficiency
97.7 % [3] [1]
Grid / off-grid modes
?
Generator input
?
Transfer time
?
Idle consumption
?
Night consumption
15 W [1]
Parallel units
?

Communication and environment

Communications
?
Operating temperature
-35 to 60 °C / -31 to 140 °F converted [3] [1]
Enclosure rating
IP66 [3] [1]
Operating noise
56 dB [3]

Mechanical

Dimensions
W 520 × H 660 × D 260 mm / W 20.5 × H 26 × D 10.2 in converted [3] [1]
Weight
65 kg / 140 lb converted [3] [1]

Installation (from the manual)

Conductors

Battery conductors
Single-core outdoor copper cable, 25mm2, outer diameter 9.4mm- 10.6mm [3]
AC input conductors
?
AC output conductors
Single-core outdoor copper cable, 16mm2-25mm2 [3]
PV conductors
?
Ground conductor
?

Protection

AC input breaker
?
AC output breaker
Nominal Voltage ≥400V, Rated Current ≥100A (ON-GRID, BACK-UP and generator circuit breakers) [3]
Battery fuse or breaker
?
PV disconnect
?

Clearances and orientation

Installation clearances
?
Mounting orientation
Wall Mounted [3]

Not in the manual: Torque, Grounding, Communication

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

GoodWe GW50K-ET-10 · GW50K-ET-10

Warranty

Warranty term5 years[4]
Optional extension?
Coverage startsEarlier of first installation or 6 months after production[4]
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?
TerritoryInternational market except China mainland, Hong Kong, Macao, Taiwan, Australia, New Zealand, America, Canada, Brazil and European countries[4]

Certifications and listings

UL 1741?
UL 1741 SA?
UL 1741 SB?
IEEE 1547?
CA Rule 21?
UL 9540?
FCC Part 15?

Documents and sources

  1. GoodWe ET 25-50kW Series datasheet (GoodWe-Single page-20251022-EN-V2.1) Manufacturer datasheet · Revision GoodWe-Single page-20251022-EN-V2.1 · Checked Sep 24, 2026 https://en.goodwe.com/Ftp/EN/Downloads/Datasheet/GW_ET-25-50kW_Datasheet-EN.pdf
  2. GoodWe GW50K-ET-10 product identity manufacturer · Checked Sep 15, 2026 https://en.goodwe.com/et-25-50kw
  3. GoodWe Commercial and Industrial Smart Inverter Solutions, ET Series (25-50kW) Solutions Manual (V2.5 2026-09-24) User manual · Revision V2.5 2026-09-24 · Revised 2026-09 · Checked Oct 1, 2026 https://en.goodwe.com/Skippower/downloadFileF?id=2494&mid=60
  4. GOODWE Limited Warranty for Inverter System (for Global market), Rev: 5.3 20260917 Manufacturer warranty policy · Revision Rev: 5.3 20260917 · Revised Sep 17, 2026 · Checked Sep 24, 2026 https://en.goodwe.com/Ftp/Downloads/Warranty/GOODWE%20Limited%20Warranty%20for%20Inverter%20System-GLOBAL.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/inverters/goodwe-gw50k-et-10Some links pay us a commission. That does not affect what we record.