conditions: GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28) prints the model code GW3.6K-EHA-G20 and no separate ordering SKU.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Weight
24 kg / 53 lb converted
Printed as "24" in the GW3.6K-EHA-G20 column of the Weight (kg) row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 275 (printed page 274); read from the rendered page and checked against the text layer.
Where: User manual PDF page 275 (printed page 274), 10.1 Inverter Parameters, General Data section, Weight (kg) row, GW3.6K-EHA-G20 column
Printed as "2" in the GW3.6K-EHA-G20 column of the Number of MPPTs row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 270 (printed page 269); read from the rendered page and checked against the text layer.
Where: User manual PDF page 270 (printed page 269), 10.1 Inverter Parameters, PV Side section, Number of MPPTs row, GW3.6K-EHA-G20 column
Printed as "3.6 (7.2, 10s)" in the GW3.6K-EHA-G20 column of the Max. Output Apparent Power (kVA) row (Back-up Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 272 (printed page 271); read from the rendered page and checked against the text layer. Back-up port maximum apparent power (kVA); the first figure is the continuous one and the bracket gives the 10-second figure.
Where: User manual PDF page 272 (printed page 271), 10.1 Inverter Parameters, Back-up Side section, Max. Output Apparent Power (kVA) row, GW3.6K-EHA-G20 column
Printed as "220/230/240 , L/N/ PE" in the GW3.6K-EHA-G20 column of the Nominal Voltage (V) row (AC Side (On-grid)) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 271 (printed page 270); read from the rendered page and checked against the text layer.
Where: User manual PDF page 271 (printed page 270), 10.1 Inverter Parameters, AC Side (On-grid) section, Nominal Voltage (V) row, GW3.6K-EHA-G20 column
Printed as "14.3" in the GW3.6K-EHA-G20 column of the Max. Continuous Charging Current (A) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 269 (printed page 268); read from the rendered page and checked against the text layer.
Where: User manual PDF page 269 (printed page 268), 10.1 Inverter Parameters, Battery Side section, Max. Continuous Charging Current (A) row, GW3.6K-EHA-G20 column
W 800 × H 300 × D 270 mm / W 31.5 × H 11.8 × D 10.6 in converted
Printed as "800*300*270" in the GW3.6K-EHA-G20 column of the Dimension (W×H×D mm) row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 275 (printed page 274); read from the rendered page and checked against the text layer. The row is headed W×H×D.
Where: User manual PDF page 275 (printed page 274), 10.1 Inverter Parameters, General Data section, Dimension (W×H×D mm) row, GW3.6K-EHA-G20 column
Printed as "97.6%" in the GW3.6K-EHA-G20 column of the Max. Efficiency row (Efficiency) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 273 (printed page 272); read from the rendered page and checked against the text layer.
Where: User manual PDF page 273 (printed page 272), 10.1 Inverter Parameters, Efficiency section, Max. Efficiency row, GW3.6K-EHA-G20 column
Printed as "40~560" in the GW3.6K-EHA-G20 column of the MPPT Operating Voltage Range (V) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 270 (printed page 269); read from the rendered page and checked against the text layer.
Where: User manual PDF page 270 (printed page 269), 10.1 Inverter Parameters, PV Side section, MPPT Operating Voltage Range (V) row, GW3.6K-EHA-G20 column
Printed as "7.2" in the GW3.6K-EHA-G20 column of the Max. Input Power (kW) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 269 (printed page 268); read from the rendered page and checked against the text layer.
Where: User manual PDF page 269 (printed page 268), 10.1 Inverter Parameters, PV Side section, Max. Input Power (kW) row, GW3.6K-EHA-G20 column
Printed as "50/60" in the GW3.6K-EHA-G20 column of the Nominal Frequency (Hz) row (AC Side (On-grid)) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 271 (printed page 270); read from the rendered page and checked against the text layer.
Where: User manual PDF page 271 (printed page 270), 10.1 Inverter Parameters, AC Side (On-grid) section, Nominal Frequency (Hz) row, GW3.6K-EHA-G20 column
Printed as "10.5" in the GW3.6K-EHA-G20 column of the Max. Continuous Discharging Current (A) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 269 (printed page 268); read from the rendered page and checked against the text layer.
Where: User manual PDF page 269 (printed page 268), 10.1 Inverter Parameters, Battery Side section, Max. Continuous Discharging Current (A) row, GW3.6K-EHA-G20 column
Printed as "IP66" in the GW3.6K-EHA-G20 column of the Ingress Protection Rating row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 275 (printed page 274); read from the rendered page and checked against the text layer.
Where: User manual PDF page 275 (printed page 274), 10.1 Inverter Parameters, General Data section, Ingress Protection Rating row, GW3.6K-EHA-G20 column
Printed as "20" in the GW3.6K-EHA-G20 column of the Max. MPPT Current (A) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 270 (printed page 269); read from the rendered page and checked against the text layer. Printed once for the model; read as the per-MPPT figure the row label gives (Max. MPPT ...).
Where: User manual PDF page 270 (printed page 269), 10.1 Inverter Parameters, PV Side section, Max. MPPT Current (A) row, GW3.6K-EHA-G20 column
Printed as "600" in the GW3.6K-EHA-G20 column of the Max. Input Voltage (V) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 270 (printed page 269); read from the rendered page and checked against the text layer.
Where: User manual PDF page 270 (printed page 269), 10.1 Inverter Parameters, PV Side section, Max. Input Voltage (V) row, GW3.6K-EHA-G20 column
Printed as "3.96" in the GW3.6K-EHA-G20 column of the Max. Discharging Power (kW) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 269 (printed page 268); read from the rendered page and checked against the text layer.
Where: User manual PDF page 269 (printed page 268), 10.1 Inverter Parameters, Battery Side section, Max. Discharging Power (kW) row, GW3.6K-EHA-G20 column
Printed as "380" in the GW3.6K-EHA-G20 column of the Nominal Battery Voltage (V) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 269 (printed page 268); read from the rendered page and checked against the text layer.
Where: User manual PDF page 269 (printed page 268), 10.1 Inverter Parameters, Battery Side section, Nominal Battery Voltage (V) row, GW3.6K-EHA-G20 column
Printed as "50" in the GW3.6K-EHA-G20 column of the Start-up Voltage (V) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 270 (printed page 269); read from the rendered page and checked against the text layer.
Where: User manual PDF page 270 (printed page 269), 10.1 Inverter Parameters, PV Side section, Start-up Voltage (V) row, GW3.6K-EHA-G20 column
Printed as "5.4" in the GW3.6K-EHA-G20 column of the Max. Charging Power (kW) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 269 (printed page 268); read from the rendered page and checked against the text layer.
Where: User manual PDF page 269 (printed page 268), 10.1 Inverter Parameters, Battery Side section, Max. Charging Power (kW) row, GW3.6K-EHA-G20 column
Printed as "≤10" in the GW3.6K-EHA-G20 column of the Power Self-consumption at Night (W) row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 275 (printed page 274); read from the rendered page and checked against the text layer. Printed with a less-than-or-equal sign ("≤10"): the figure is an upper limit, recorded as 10 W.
Where: User manual PDF page 275 (printed page 274), 10.1 Inverter Parameters, General Data section, Power Self-consumption at Night (W) row, GW3.6K-EHA-G20 column
Printed as "1/1" in the GW3.6K-EHA-G20 column of the Number of Strings per MPPT row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 270 (printed page 269); read from the rendered page and checked against the text layer. One figure per MPPT, in MPPT order.
Where: User manual PDF page 270 (printed page 269), 10.1 Inverter Parameters, PV Side section, Number of Strings per MPPT row, GW3.6K-EHA-G20 column
Printed as "3.6" in the GW3.6K-EHA-G20 column of the Nominal Power (kW) row (AC Side (On-grid)) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 270 (printed page 269); read from the rendered page and checked against the text layer.
Where: User manual PDF page 270 (printed page 269), 10.1 Inverter Parameters, AC Side (On-grid) section, Nominal Power (kW) row, GW3.6K-EHA-G20 column
Printed as "Wall/Floor Mounted" in the GW3.6K-EHA-G20 column of the Mounting Method row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 276 (printed page 275); read from the rendered page and checked against the text layer.
Where: User manual PDF page 276 (printed page 275), 10.1 Inverter Parameters, General Data section, Mounting Method row, GW3.6K-EHA-G20 column
Printed as "98.0%" in the GW3.6K-EHA-G20 column of the Max. Battery to AC Efficiency row (Efficiency) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 273 (printed page 272); read from the rendered page and checked against the text layer.
Where: User manual PDF page 273 (printed page 272), 10.1 Inverter Parameters, Efficiency section, Max. Battery to AC Efficiency row, GW3.6K-EHA-G20 column
Printed as "26" in the GW3.6K-EHA-G20 column of the Max. MPPT Short Circuit Current (A) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 270 (printed page 269); read from the rendered page and checked against the text layer. Printed once for the model; read as the per-MPPT figure the row label gives (Max. MPPT ...).
Where: User manual PDF page 270 (printed page 269), 10.1 Inverter Parameters, PV Side section, Max. MPPT Short Circuit Current (A) row, GW3.6K-EHA-G20 column
Printed as "350~550" in the GW3.6K-EHA-G20 column of the Battery Voltage Range (V) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 269 (printed page 268); read from the rendered page and checked against the text layer.
Where: User manual PDF page 269 (printed page 268), 10.1 Inverter Parameters, Battery Side section, Battery Voltage Range (V) row, GW3.6K-EHA-G20 column
Printed as "-35~+60 (Derating at +40)" in the GW3.6K-EHA-G20 column of the Operating Temperature Range (℃) row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 274 (printed page 273); read from the rendered page and checked against the text layer. The manual adds "(Derating at +40)": output is reduced above 40 °C.
Where: User manual PDF page 274 (printed page 273), 10.1 Inverter Parameters, General Data section, Operating Temperature Range (℃) row, GW3.6K-EHA-G20 column
Printed as "96.5%" in the GW3.6K-EHA-G20 column of the European Efficiency row (Efficiency) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 273 (printed page 272); read from the rendered page and checked against the text layer.
Where: User manual PDF page 273 (printed page 272), 10.1 Inverter Parameters, Efficiency section, European Efficiency row, GW3.6K-EHA-G20 column
64.8 L* (Calculated from published dimensions)W: 800 × H: 300 × D: 270 mm / W: 31.5 × H: 11.8 × D: 10.6 inWeight24 kg / 53 lb
Evidence score
15/100Missing details15% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Warranty term needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Battery conversion efficiency98 %15.0 / 15.0
98 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10
Printed as "98.0%" in the GW3.6K-EHA-G20 column of the Max. Battery to AC Efficiency row (Efficiency) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 273 (printed page 272); read from the rendered page and checked against the text layer.
Research pending, 0 points: Certificates, Warranty term, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
Location: Applicable Products; 10.2 Battery Technical Data
Retrieved Sep 28, 2026
GoodWe's user manual for the single-phase ESA Series, linked as "User Manual" from the ESA 3-10kW page; the link resolves to en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_ESA-3-10kW_User-Manual-EN.pdf. Captured September 29, 2026. Section 10.2 prints Battery Technical Data for the six GW...-BAT-D-G20/G21 modules. Where it differs from the later ESA 5-30kW manual (V1.5, 2026-09-04) its value is kept as an alternative. Manufacturer claims, not independently verified.
Archived copies
Archived copy of a document published by GoodWe Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
ESA Series 3-10kW user manual (GoodWe, V1.8, 2026-07-28)
Archived copy of a document published by GoodWe Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].