Printed as "Weight (kg) 48 48 54 54 54" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Weight row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 282, Technical Data, Weight row, GW25K-ET column
Printed as "Number of MPPT 2 2 3 3 3" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Number of MPPT row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 277, Technical Data, Number of MPPT row, GW25K-ET column
Printed as "Max. Output Apparent Power without Grid (VA)*5 15000 (18000@60s, 24000@3s) 20000 (24000@60s, 32000@3s) 25000 (30000@60s) 30000 (36000@60s) 30000 (36000@60s)" in the GoodWe ET 15-30kW Series datasheet (footer dated 2024-12-03, V2.1), AC output (back-up) table, GW25K-ET column, captured on September 25, 2026. The datasheet footnote says this can be reached only if PV and battery power is enough; the figure is backup (off-grid) apparent power in VA, not W.
Where: GoodWe ET 15-30kW Series datasheet, Technical Data, AC output (back-up) table, GW25K-ET column
Printed as "Output THDv (@Linear Load) <3% <3% <3% <3% <3%" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, AC Output Data (Back-up), Output THDv (@Linear Load) row, GW25K-ET column.
Where: PDF page 280, Technical Data, AC Output Data (Back-up), Output THDv (@Linear Load) row, GW25K-ET column
Printed as "Nominal Output Voltage (V) 380 / 400, 3L / N / PE" in the GoodWe ET 15-30kW Series datasheet (footer dated 2024-12-03, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe ET 15-30kW Series datasheet, Technical Data, AC output table, merged cell
Printed as "Max. Continuous Charging Current (A) 50 50 50 × 2 50 × 2 50 × 2" in the GoodWe ET 15-30kW Series datasheet (footer dated 2024-12-03, V2.1), Battery input table, GW25K-ET column, captured on September 25, 2026.
Where: GoodWe ET 15-30kW Series datasheet, Technical Data, Battery input table, GW25K-ET column
Printed as "industry-standard outdoor photovoltaic cables" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), 5.3.2 Cable Preparation, PVDC cable row.
Where: PDF page 133, 5.3.2 Cable Preparation, PVDC cable row
W 520 × H 660 × D 220 mm / W 20.5 × H 26 × D 8.66 in converted
Printed as "Dimension W×H×D (mm) 520×660 ×220" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Dimension W×H×D (mm) row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Printed as "Max. Efficiency 98.0% 98.0% 98.0% 98.0% 98.0%" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Max. Efficiency row, GW25K-ET column. Printed as 98.0%; recorded as 98. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Printed as "MPPT Operating Voltage Range (V) 200~850 200~850 200~850 200~850 200~850" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, MPPT Operating Voltage Range row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 276, Technical Data, MPPT Operating Voltage Range row, GW25K-ET column
Printed as "Max. Input Power (W)*1 22500 30000 37500 45000 45000" in the GoodWe ET 15-30kW Series datasheet (footer dated 2024-12-03, V2.1), PV input table, GW25K-ET column, captured on September 25, 2026. Maximum PV input power; the datasheet footnotes limit how long it may be sustained.
Where: GoodWe ET 15-30kW Series datasheet, Technical Data, PV input table, GW25K-ET column
Printed as "Nominal AC Grid Frequency (Hz) 50 / 60" in the GoodWe ET 15-30kW Series datasheet (footer dated 2024-12-03, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe ET 15-30kW Series datasheet, Technical Data, AC output table, merged cell
Printed as "Max. Continuous Discharging Current (A) 50 50 50 × 2 50 × 2 50 × 2" in the GoodWe ET 15-30kW Series datasheet (footer dated 2024-12-03, V2.1), Battery input table, GW25K-ET column, captured on September 25, 2026.
Where: GoodWe ET 15-30kW Series datasheet, Technical Data, Battery input table, GW25K-ET column
Printed as "Ingress Protection Rating IP66 IP66 IP66 IP66 IP66" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Ingress Protection Rating row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Printed as "S=6mm²" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), 5.3.2 Cable Preparation, Inverter Protection Ground Wire row.
Printed as "Max. Input Voltage (V)*2 1000 1000 1000 1000 1000" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Max. Input Voltage row, GW25K-ET column. Footnote 2 on PDF page 283 reads "For 1000V system,Maximum operating voltage is 950V." Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 276, Technical Data, Max. Input Voltage row, GW25K-ET column
ON-GRID circuit breaker: Rated Current ≥50A when the BACK-UP port is unloaded, ≥63A when it is loaded; Nominal Voltage ≥400V
Printed as "GW25K-ET: Rated Current≥50A; Nominal Voltage≥400V" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), 5.3.1 Circuit breaker preparation, ON-GRID circuit breaker row, GW25K-ET lines. The BACK-UP circuit breaker row on PDF page 130 gives Rated Current ≥50A for this model.
Printed as "Max Discharge Power (W) 15000 20000 25000 30000 30000" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Max Discharge Power row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 276, Technical Data, Max Discharge Power row, GW25K-ET column
Single-core outdoor copper cable, 10mm² (outer diameter 6.0mm- 9.5mm for terminal type I, 5mm- 8.5mm for terminal type II)
Printed as "Terminal typeI Single-core outdoor copper cable" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), 5.3.2 Cable Preparation, Battery DC cable rows (terminal type I on PDF page 133, terminal type II on PDF page 134).
Where: PDF page 133, 5.3.2 Cable Preparation, Battery DC cable rows (terminal type I on PDF page 133, terminal type II on PDF page 134)
Printed as "Nominal Battery Voltage (V) 500 500 500 500 500" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Nominal Battery Voltage row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 276, Technical Data, Nominal Battery Voltage row, GW25K-ET column
2P DC Switch, Rated Current ≥63A, Nominal Voltage ≥1000V
Printed as "2PDC Switch• Rated Current≥63A• Nominal Voltage≥1000V" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), 5.3.1 Circuit breaker preparation, Battery Switch row. The manual says to select the battery switch according to local laws and regulations.
Printed as "Start-up Voltage (V) 200 200 200 200 200" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, PV String Input Data, Start-up Voltage row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 276, Technical Data, PV String Input Data, Start-up Voltage row, GW25K-ET column
Printed as "Multi-core outdoor copper core cable" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), 5.3.2 Cable Preparation, AC cable row.
Where: PDF page 134, 5.3.2 Cable Preparation, AC cable row
Printed as "Self-consumption at Night (W)*7 <15" in the GoodWe ET 15-30kW Series datasheet (footer dated 2024-12-03, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026. Its footnote *7 reads "No Back-up Output."
Where: GoodWe ET 15-30kW Series datasheet, Technical Data, General data table, merged cell
Printed as "Noise Emission (dB) <45 <45 <45 <60 <60" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Noise Emission (dB) row, GW25K-ET column. The bound is kept as printed; the manual prints the unit as dB.
Printed as "Nominal Output Power (W) 15000 20000 25000 29900 30000" in the GoodWe ET 15-30kW Series datasheet (footer dated 2024-12-03, V2.1), AC output table, GW25K-ET column, captured on September 25, 2026.
Where: GoodWe ET 15-30kW Series datasheet, Technical Data, AC output table, GW25K-ET column
GoodWe prints no standby consumption figure for this model in the GoodWe ET 15-30kW Series datasheet; its "Self-consumption at Night" row is recorded as night consumption. Revised on 30 September 2026: The 15 W figure is printed as consumption at night ("Self-consumption at Night"), not as standby consumption; it moves to night consumption and standby consumption is unknown.
Where: GoodWe ET 15-30kW Series datasheet, Technical Data, General data table, merged cell
Printed as "Max. Battery to AC Efficiency 97.5% 97.5% 97.5% 97.5% 97.5%" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Max. Battery to AC Efficiency row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 280, Technical Data, Max. Battery to AC Efficiency row, GW25K-ET column
Printed as "Max. Short Circuit Current per MPPT (A) 38 38 38 38 38" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Max. Short Circuit Current per MPPT row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 277, Technical Data, Max. Short Circuit Current per MPPT row, GW25K-ET column
Printed as "Battery voltage range (V) 200~800 200~800 200~800 200~800 200~800" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Battery voltage range row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 276, Technical Data, Battery voltage range row, GW25K-ET column
Printed as "Operating Temperature Range (℃) -35~+60 -35~+60 -35~+60 -35~+60 -35~+60" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Operating Temperature Range row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 281, Technical Data, Operating Temperature Range row, GW25K-ET column
Printed as "European Efficiency 97.5% 97.5% 97.5% 97.5% 97.5%" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, European Efficiency row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 280, Technical Data, European Efficiency row, GW25K-ET column
75.5 L* (Calculated from published dimensions)W: 520 × H: 660 × D: 220 mm / W: 20.5 × H: 26 × D: 8.66 inWeight54 kg / 120 lb
Evidence score
21/100Missing details45% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed in item 1 of the GOODWE Limited Warranty for Inverter System (for Global market), Rev: 5.3 20260917, captured on September 25, 2026, which lists the ET 15-30K series under a 5-year limited warranty. The policy names series, not models, and applies only in the international market its Geographical Scope clause defines (it excludes America, Canada, Brazil, Europe, Australia, New Zealand and greater China); exclusions and claim steps apply.
97.5 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10
Printed as "Max. Battery to AC Efficiency 97.5% 97.5% 97.5% 97.5% 97.5%" in GoodWe's Commercial Smart Inverter Solutions user manual for ET 12-30kW systems (V2.2 2026-09-15), Technical Data, Max. Battery to AC Efficiency row, GW25K-ET column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Research pending, 0 points: Certificates, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 15 to 50 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Territory
International market except China mainland, Hong Kong, Macao, Taiwan, Australia, New Zealand, America, Canada, Brazil and European countries
Printed as "This GOODWE Limited warranty terms and conditions applies for international market except China mainland, Hong Kong, Macao, Taiwan, Australia, New Zealand, America, Canada, Brazil or European countries" in the Geographical Scope clause of the same policy, captured on September 25, 2026; those regions have separate GoodWe terms.
Earlier of first installation or 6 months after production
Printed as "starting from the earlier one of following two dates: 1. The date on which the product was first installed. 2. 6 months after the date of production." in the same policy, captured on September 25, 2026.
Global-market policy; not the United States or Canada
Printed in item 1 of the GOODWE Limited Warranty for Inverter System (for Global market), Rev: 5.3 20260917, captured on September 25, 2026, which lists the ET 15-30K series under a 5-year limited warranty. The policy names series, not models, and applies only in the international market its Geographical Scope clause defines (it excludes America, Canada, Brazil, Europe, Australia, New Zealand and greater China); exclusions and claim steps apply.
Location: PDF page 3, Applicable Products; PDF pages 276 to 291, 9.1 Inverter Parameters
Retrieved Oct 1, 2026
GoodWe's own user manual for energy storage systems built on the ET 12-30kW hybrid inverters, linked as a User Manual from GoodWe's ET 15-30kW product page and captured 1 October 2026 from en.goodwe.com; revision V2.2 2026-09-15 as printed. Its Technical Data tables name GW15K-ET, GW20K-ET, GW25K-ET, GW29.9K-ET and GW30K-ET, and a second table names GW12KL-ET, GW18KL-ET, GW20K-ET and GW30K-ET. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Technical Data table, one column per model
Retrieved Sep 24, 2026
GoodWe family datasheet (ET 15-30kW Series), fetched from en.goodwe.com (the file the series page en.goodwe.com/et-15-30kw links as "Datasheet") and archived on September 25, 2026. Its Technical Data table sets the models side by side, one column per model, so each figure is read from the named model column and the whole row is quoted; a value printed once spans every column. It names models, not ordering SKUs. It is a manufacturer claim; no figure was tested independently.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Overview and Geographical Scope
Retrieved Sep 24, 2026
GoodWe limited warranty for inverters sold in its global market. It names series, not models: 5 years for the on-grid and hybrid series it lists. Fetched from en.goodwe.com (linked from en.goodwe.com/warranty) and archived on September 25, 2026. The policy's Geographical Scope clause limits it to devices bought from authorized channels and installed in the international market it defines, which excludes the regions GoodWe covers with separate terms (the United States and Canada among them). It is the manufacturer's published policy, not a purchaser-specific contract.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
GoodWe ET 15-30kW Series datasheet (GoodWe-Single page-20241203-EN-V2.1)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
GOODWE Limited Warranty for Inverter System (for Global market), Rev: 5.3 20260917
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
GoodWe Commercial Smart Inverter Solutions User Manual, ET 12-30kW systems (V2.2 2026-09-15)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].