10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 10 Years".
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 40 kg / 88 lb converted | Printed as 40 kg (88 lb). Where: PDF page 2, technical data, General | [1] |
| MPPT count | 2 | The number of MPPTs. Where: PDF page 2, technical data, Input PV | [1] |
| Peak output | 12,000 VA (1 s) | The backup peak power for one second. Where: PDF page 2, technical data, Output Backup | [1] |
| AC voltage | 120/240 V (split phase); 208 V (2/3 phase) | The nominal grid voltage row. Where: PDF page 2, technical data, Output Grid | [1] |
| Max charge | 210 A | The first figure of the maximum charge/discharge current row. Where: PDF page 2, technical data, Input/Output BAT | [1] |
| Dimensions | W 420 × H 800 × D 240 mm / W 16.5 × H 31.5 × D 9.45 in converted | Printed as 420 x 800 x 240 mm (W x H x D). Where: PDF page 2, technical data, General | [1] |
| Efficiency | 98 % | The maximum PV to AC efficiency (the sheet spells it "Efficency"). Where: PDF page 2, technical data, Efficiency | [1] |
| MPPT voltage | 70 to 540 V | The MPPT operating voltage range. Where: PDF page 2, technical data, Input PV | [1] |
| Solar input | 9 kWConverted: 9000 W / 1000 W/kW | The maximum PV input power, printed as 9,000 W. Where: PDF page 2, technical data, Input PV SourcesConverted: 9000 W / 1000 W/kW | [1] |
| Max discharge | 130 A | The second figure of the maximum charge/discharge current row. Where: PDF page 2, technical data, Input/Output BAT | [1] |
| Enclosure rating | NEMA 3R | The ingress protection row. Where: PDF page 2, technical data, General | [1] |
| Max PV voltage | 600 V | The maximum PV voltage. Where: PDF page 2, technical data, Input PV | [1] |
| Transfer time | 10 ms | Printed as less than 10 ms (typical); 10 ms is the stated upper bound. Where: PDF page 2, technical data, Output Backup | [1] |
| Apparent power | 6,600 VA | The maximum AC output apparent power. Where: PDF page 2, technical data, Output Grid | [1] |
| Nominal voltage | 48 V | The nominal battery voltage. Where: PDF page 2, technical data, Input/Output BAT | [1] |
| Max parallel units | 9 count | Printed as "Stack up to 9 inverters in parallel". Where: PDF page 1, features | [1] |
| PV start voltage | 90 V | The PV start-up voltage. Where: PDF page 2, technical data, Input PV | [1] |
| Certification claims | UL 1741; CSA C22.2; UL 1699B; UL1741SB; IEEE1547: 2018 | Standards printed in the certification rows (safety and grid); manufacturer claims, no issuer directory was checked. Where: PDF page 2, technical data, Certification | [1] |
| Continuous output | 6 kWConverted: 6000 W / 1000 W/kW | The nominal AC output power, printed as 6,000 W. Where: PDF page 2, technical data, Output Grid SourcesConverted: 6000 W / 1000 W/kW | [1] |
| Battery voltage range | 40 to 64 V | The battery voltage range. Where: PDF page 2, technical data, Input/Output BAT | [1] |
| Operating temperature | -25 to 60 °C / -13 to 140 °F converted | Printed as -25 to 60 °C, derating above 45 °C. Where: PDF page 2, technical data, General | [1] |
| Other compliance claims | HECO SRD 2.0; FCC Part 15 Class B | Grid and EMC marks printed beside the numbered standards. Where: PDF page 2, technical data, Certification | [1] |
| Weighted efficiency | 96.5 % | The CEC efficiency. Where: PDF page 2, technical data, Efficiency | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 10 Years".
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 10 years | Printed as "Warranty 10 Years". Where: PDF page 2, technical data, Warranty | [1] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Captured Nov 2, 2026 (archived copy).
Location: PDF page 1, overview and specifications; PDF page 2, technical data
Retrieved Nov 2, 2026
Fortress Power's EdgeOn Duo 9 split-phase hybrid inverter data sheet (V.EDGE9_0126), listed on fortresspower.com (product page downloads or the WP File Download document pages) and fetched directly from fortresspower.com with the paced research fetcher on November 3, 2026 (robots.txt checked first; request ended 04:04:43.901 UTC). Manufacturer claims, not independent tests.
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Fortress Power published. Original address: https://www.fortresspower.com/download/955/edgeon-duo/48042/fortress-power-edgeon-duo-9-data-sheet-english.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: cc0dbf4eabd8808e76869b14f9e174ccc97a1bef24cd17461abf9936e9b621d5
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Fortress Power published. Original address: https://www.fortresspower.com/download/955/edgeon-duo/48042/fortress-power-edgeon-duo-9-data-sheet-english.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: cc0dbf4eabd8808e76869b14f9e174ccc97a1bef24cd17461abf9936e9b621d5
No sourced accessories or replacement parts listed yet.
US market
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Listing stated, none checked shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 10 unit: Unknown shown: 10 years shown detail: Unknown state: documented points: 12 ceiling: 30 weight: 30 share: 40 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.