10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "generator support yes limited warranty 10 years".
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 40.64 kg / 89.6 lb converted | Printed once for both columns as 40.64 kg (89.59 lb). Where: PDF page 3, Avalon hybrid inverter, General Data | [1] |
| MPPT count | 4 | Four MPPTs, one string each. Where: PDF page 3, Avalon hybrid inverter, DC Input (PV) | [1] |
| Peak output | 12.2 kVA for 10 s (off-grid) | The maximum apparent output power (off-grid) in the 7.6 column, printed as "12.2 kVa, 10 sec". Where: PDF page 3, Avalon hybrid inverter, AC Output | [1] |
| AC voltage | 240 V (L1-L2); 120 V (L1/L2-N) | The rated output voltage rows. Where: PDF page 3, Avalon hybrid inverter, AC Output | [1] |
| Max charge | 50 A | The maximum charge/discharge current. Where: PDF page 3, Avalon hybrid inverter, Energy Storage | [1] |
| Dimensions | W 555.5 × H 866 × D 219 mm / W 21.87 × H 34.1 × D 8.62 in converted | Printed once for both columns as 555.5 x 866 x 219 mm (W x H x D). Where: PDF page 3, Avalon hybrid inverter, General Data | [1] |
| Efficiency | 97.6 % | The PV maximum efficiency. Where: PDF page 3, Avalon hybrid inverter, Efficiency | [1] |
| MPPT voltage | 80 to 520 V | The MPPT voltage range. Where: PDF page 3, Avalon hybrid inverter, DC Input (PV) | [1] |
| Solar array | 18.24 kW | Printed in the feature list as a maximum 18.24 kW PV array; the sheet does not split it by column. Where: PDF page 3, Avalon hybrid inverter, features | [1] |
| Max discharge | 50 A | The maximum charge/discharge current. Where: PDF page 3, Avalon hybrid inverter, Energy Storage | [1] |
| Enclosure rating | TYPE 4X (IP66) | The ingress protection row. Where: PDF page 3, Avalon hybrid inverter, General Data | [1] |
| Max PV voltage | 600 V | The maximum PV input voltage. Where: PDF page 3, Avalon hybrid inverter, DC Input (PV) | [1] |
| Apparent power | 7,600 VA | The maximum apparent output power (grid) in the 7.6 column, printed as 7.6 kVa. Where: PDF page 3, Avalon hybrid inverter, AC Output SourcesConverted: 7.6 kVA x 1000 VA/kVA | [1] |
| Generator support | Yes | Printed as "generator support yes". Where: PDF page 3, Avalon hybrid inverter, General Data | [1] |
| PV start voltage | 80 V | The PV start-up voltage. Where: PDF page 3, Avalon hybrid inverter, DC Input (PV) | [1] |
| Certification claims | UL 1741; UL 1741 SA; UL 1741 SB; UL9540; IEEE 1547-2018; IEEE 1547.1-2020; UL 1699B; UL 1998; CAN/CSA C22.2107.1-1 | Standards printed in the compliance row, which covers both columns. Manufacturer claims, no issuer directory was checked. Where: PDF page 3, Avalon hybrid inverter, General Data, compliance row | [1] |
| Continuous output | 7.6 kW | The rated output power in the 7.6 column, printed as 7.6 kW. Where: PDF page 3, Avalon hybrid inverter, AC Output | [1] |
| Max output current | 31.7 A | The maximum output current (grid) in the 7.6 column. Where: PDF page 3, Avalon hybrid inverter, AC Output | [1] |
| Battery voltage range | 120 to 315 V | The battery voltage range (high-voltage battery). Where: PDF page 3, Avalon hybrid inverter, Energy Storage | [1] |
| Operating temperature | -25 to 60 °C / -13 to 140 °F converted | Printed as -25 to 60 °C (-13 to 140 °F). Where: PDF page 3, Avalon hybrid inverter, General Data | [1] |
| Other compliance claims | California Rule 21; HECO Rule 14H; NEC 690.12-2020; FCC Part 15 Class B | Marks printed beside the numbered standards. Where: PDF page 3, Avalon hybrid inverter, General Data, compliance row | [1] |
| Weighted efficiency | 97.2 % | The PV CEC efficiency. Where: PDF page 3, Avalon hybrid inverter, Efficiency | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "generator support yes limited warranty 10 years".
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 10 years | Printed as "generator support yes limited warranty 10 years". Where: PDF page 3, Avalon hybrid inverter, General Data | [1] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Captured Nov 2, 2026 (archived copy).
Location: PDF page 2, Avalon Smart Energy Panel; PDF page 3, Avalon hybrid inverter; PDF page 4, Avalon BMS and battery pack
Retrieved Nov 2, 2026
Fortress Power's Avalon Energy Storage System data sheet (Avalon Smart Energy Panel, Avalon hybrid inverter and Avalon BMS and battery pack), listed in the Avalon document category of fortresspower.com, listed on fortresspower.com (product page downloads or the WP File Download document pages) and fetched directly from fortresspower.com with the paced research fetcher on November 3, 2026 (robots.txt checked first; request ended 04:05:41.661 UTC). Manufacturer claims, not independent tests.
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Fortress Power published. Original address: https://www.fortresspower.com/download/954/avalon/47989/fortress-power-avalon-data-sheet.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: e58c0ee0358ae8a65dbfc761ac5d7ecc38343299e6ec92e4ca5d55c344780051
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Fortress Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Fortress Power published. Original address: https://www.fortresspower.com/download/954/avalon/47989/fortress-power-avalon-data-sheet.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: e58c0ee0358ae8a65dbfc761ac5d7ecc38343299e6ec92e4ca5d55c344780051
No sourced accessories or replacement parts listed yet.
Manufacturer SKU AVALON HV PC076 · US market
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Listing stated, none checked shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 10 unit: Unknown shown: 10 years shown detail: Unknown state: documented points: 12 ceiling: 30 weight: 30 share: 40 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.