Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Enphase IQ9N-3P-277 Commercial Microinverter, manufacturer product image from the enphase.com IQ9N (277 V) for Commercial Solar store page og:image tag (September 28, 2026 capture).Enphase IQ9N Commercial Microinverter IQ9N-3P-277-A-DOM-US
Key specs
All specifications
No spec by that name.
Show all 16 specifications
Identity
SKU detail
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 1.2 kg / 2.6 lb converted | Printed as 2.65 lb (1.2 kg). Where: Mechanical data, row "Weight" | [1] |
| Dimensions | W 192.1 × H 215.5 × D 32.3 mm / W 7.56 × H 8.48 × D 1.27 in converted | Printed as H x W x D without mounting brackets. Where: Mechanical data, row "Dimensions (H x W x D)" | [1] |
| MPPT voltage | 28 to 45 V | Peak power tracking voltage. Where: Input data (DC), row "Peak power tracking voltage" | [1] |
| AC configuration | 277 V (L-N) | Printed as 277 V (L-N); the microinverter outputs single-phase AC and is used in a 480 VAC WYE three-phase branch circuit with phase balancing achieved through a three-phase QD Cable, as the document's footnote states. Where: Output data (AC), row "Nominal grid voltage" | [1] |
| Enclosure rating | NEMA Type 6 | Printed as "NEMA Type 6; outdoor". Where: Mechanical data, row "Environmental category/UV exposure rating" | [1] |
| Max PV current | 16 A | Maximum DC continuous current (module Imp). Where: Input data (DC), row "Maximum DC continuous current (module Imp)" | [1] |
| Max PV voltage | 60 V | Maximum input DC voltage. Where: Input data (DC), row "Maximum input DC voltage" | [1] |
| Apparent power | 427 VA | Peak output power. Where: Key specifications / Output data (AC), row "Peak output power" | [1] |
| Continuous output | 0.427 kW | Maximum continuous output power, printed as the same figure as peak output power for this SKU. Where: Output data (AC), row "Maximum continuous output power" | [1] |
| Operating temperature | -40 to 65 °C / -40 to 149 °F converted | Ambient air temperature range. Where: Mechanical data, row "Ambient air temperature range" | [1] |
| Weighted efficiency | 97.5 % | CEC weighted efficiency. Where: Output data (AC), row "CEC weighted efficiency" | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Continuous output
- 0.43 kW
- Battery voltage
- Not stated
- Solar input
- Not statedMPPT trackers Not statedMPPT range 28 to 45 V
- AC output
- 277 V (L-N)
- Warranty
- Not stated
- Size
- 1.34 L* (Calculated from published dimensions)W: 192.1 × H: 215.5 × D: 32.3 mm / W: 7.56 × H: 8.48 × D: 1.27 inWeight 1.2 kg / 2.6 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Research pending, 0 points: Warranty term, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
How it worksCertificates
A green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.
CA Rule 21 and IEEE 1547 (UL 1741-SA/SB)manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ9N-3P-277-A-DOM-US
- Limitations
- Listed by Enphase under Standards / Grid compliance in Enphase's IQ9N Commercial Microinverter data sheet DSH-00712-7.0, printed for IQ9N-3P-277-A-DOM-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
CAN/CSA-C22.2 No. 107.1-01manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ9N-3P-277-A-DOM-US
- Limitations
- Listed by Enphase under Standards / Grid compliance in Enphase's IQ9N Commercial Microinverter data sheet DSH-00712-7.0, printed for IQ9N-3P-277-A-DOM-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
FCC Part 15 Class Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ9N-3P-277-A-DOM-US
- Limitations
- Listed by Enphase under Standards / Grid compliance in Enphase's IQ9N Commercial Microinverter data sheet DSH-00712-7.0, printed for IQ9N-3P-277-A-DOM-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
ICES-0003 Class Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ9N-3P-277-A-DOM-US
- Limitations
- Listed by Enphase under Standards / Grid compliance in Enphase's IQ9N Commercial Microinverter data sheet DSH-00712-7.0, printed for IQ9N-3P-277-A-DOM-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741/IEEE 1547manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ9N-3P-277-A-DOM-US
- Limitations
- Listed by Enphase under Standards / Grid compliance in Enphase's IQ9N Commercial Microinverter data sheet DSH-00712-7.0, printed for IQ9N-3P-277-A-DOM-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 62109-1manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ9N-3P-277-A-DOM-US
- Limitations
- Listed by Enphase under Standards / Grid compliance in Enphase's IQ9N Commercial Microinverter data sheet DSH-00712-7.0, printed for IQ9N-3P-277-A-DOM-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741 SBauthority listing reportedlisted as of snapshot[2]
- Scope
- equipment listing
- Covered models
- IQ9N-3P-277-A-DOM-US
- Limitations
- Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ9N-3P-277-A-DOM-US {277V}": UL 1741 SB, certifying entity Intertek, certificate date 2025-11-18, CEC listing date 2025-12-22. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Nov 18, 2025Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [2]
CECauthority listing reportedlisted as of snapshot[2]
- Scope
- equipment listing
- Covered models
- IQ9N-3P-277-A-DOM-US
- Limitations
- Model IQ9N-3P-277-A-DOM-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ9N-3P-277-A-DOM-US {277V}", CEC listing date 2025-12-22. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Dec 22, 2025Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [2]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Datasheets
- Enphase IQ9 Commercial Microinverters data sheetOpen
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Retrieved Sep 27, 2026
Archived copies
Archived copy of a document published by Enphase. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 1.49 MBArchived copy, unaltered, kept as a record of what Enphase published. Original address: https://enphase.com/download/iq9-commercial-microinverters-data-sheet. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 09f1de1a9bb655fbc866a7224da3abcd7c53bde5d3851be4001db846daa1cb28
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Enphase IQ9 Commercial Microinverters data sheet
Archived copy of a document published by Enphase. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Enphase published. Original address: https://enphase.com/download/iq9-commercial-microinverters-data-sheet. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 09f1de1a9bb655fbc866a7224da3abcd7c53bde5d3851be4001db846daa1cb28
Matched on printed specifications
Not documented: Battery voltage range.
Matched on printed specifications only: each maker's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a maker does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- IQ9N-3P-277-A-DOM-US
Manufacturer SKU IQ9N-3P-277-A-DOM-US · US market
Observed Oct 11, 2026
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ9N-3P-277-A-DOM-US {277V}": UL 1741 SB, certifying entity Intertek, certificate date 2025-11-18, CEC listing date 2025-12-22. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model IQ9N-3P-277-A-DOM-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ9N-3P-277-A-DOM-US {277V}", CEC listing date 2025-12-22. This is an equipment listing, not UL certification or complete-system approval.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 45 basis: Unknown missing: Warranty term needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 31.5 unit: Unknown shown: UL 1741 SB +7 shown detail: Claimed state: claimed points: 14.2 ceiling: 45 weight: 45 share: 31.5 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [2] key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Enphase IQ9 Commercial Microinverters data sheet (Enphase · manufacturer · observed Sep 27, 2026)
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
Sign in to report an error on this page
Similar products
All with a priceEnphase IQ8HC Microinverter IQ8HC-72-M-DOM-US
Duracell Power Center D350-M1A Microinverter
Enphase IQ8A Microinverter IQ8A-72-2-US
Enphase IQ8M Microinverter IQ8M-72-2-US
* Missing details