Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Enphase IQ8X Microinverter, manufacturer product image from the enphase.com IQ8X Microinverter store page og:image tag (September 28, 2026 capture). The same physical product image applies to the domestic-content IQ8X-80-M-DOM-US SKU.Microinverter
Enphase IQ8X Microinverter IQ8X-80-M-DOM-US
Key specs
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Grounding | No grounding electrode conductor, equipment grounding conductor or grounded conductor (neutral) required; Class II double-insulated with ground fault protection; the AHJ may require bonding the mounting bracket to the racking | Printed as "do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductors (neutral)." and "The microinverter has a Class II double-insulated rating, including ground fault protection (GFP)." in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 2.2 Grounding considerations. Where: PDF page 13, section 2.2 Grounding considerations | [2] |
| Weight | 1.1 kg / 2.4 lb converted | Printed as "Weight 2.42 lb (1.1 kg)" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Weight row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source. Where: PDF page 44, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Weight row | [2] [1] |
| Voltage thd | <5% | Printed as "Total harmonic distortion % <5" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, AC parameters, Total harmonic distortion row. Where: PDF page 43, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, AC parameters, Total harmonic distortion row | [2] |
| Clearances | At least 1.9 cm (3/4 in) between the roof and the microinverter and 1.3 cm (1/2 in) between the back of the PV module and the top of the microinverter; for a vertical mount, more than 30 cm (12 in) from the edges of the PV module | Printed as "Allow a minimum of ¾ in (1.9 cm) between the roof and the microinverter. Also, allow ½ in (1.3 cm) between the back of the PV module and the top of the microinverter." and "For a vertical mount, maintain a clearance of >12 in (30 cm) from the edges of the PV module" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 4.3 Mount the microinverters. Where: PDF page 18, section 4.3 Mount the microinverters | [2] |
| Dimensions | W 175 × H 212 × D 30.2 mm / W 6.89 × H 8.35 × D 1.19 in converted | Printed as "Dimensions (W × H × D) 6.9" × 8.3" × 1.2" (175 mm × 212 mm × 30.2 mm)" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Dimensions (W × H × D) row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source. Where: PDF page 44, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Dimensions (W × H × D) row | [2] [1] |
| Efficiency | 97.3 % | Peak efficiency for the 240 V configuration. Where: Output data (AC), row "Peak efficiency", 240 V column Sources97 % The 208 V configuration prints a peak efficiency of 97.0%. [1] | [1] |
| MPPT voltage | 43 to 60 V | Printed as "MPPT voltage range V 43–60" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, MPPT voltage range row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source. Where: PDF page 42, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, MPPT voltage range row | [2] [1] |
| AC configuration | 240 V split-phase (L-L) or 208 V single-phase (L-L) | Printed as "8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications"; "Nominal grid voltage (L-L) V Split-phase (L-L), 180° @ 240 VAC Single-phase (L-L), 120° @ 208 VAC"; "do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductors (neutral)" in Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (PDF page 42; PDF page 13). Revised on 16 October 2026: Owner report 2026-10-16 (inverter filter AC output 120/240 V): the earlier text read as a 120/240 V unit; the manual prints a 240 V (or 208 V) output between the two lines only, with no 120 V output. Where: PDF page 42; PDF page 13 Sources208 V, single-phase (L-L), 120 degrees The same row prints a 208 V single-phase configuration for this SKU. [1] | [2] |
| Enclosure rating | NEMA Type 6 | Printed as "NEMA Type 6/Outdoor". Where: Mechanical data, row "Environmental category/UV exposure rating" | [1] |
| Max PV current | 10 A | Printed as "Maximum continuous operating DC A 10" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum continuous operating DC row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source. Where: PDF page 42, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum continuous operating DC row | [2] [1] |
| Max PV voltage | 79.5 V | Printed as "Maximum input DC voltage V 79.5" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC voltage row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source. Where: PDF page 42, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC voltage row | [2] [1] |
| Apparent power | 384 VA | Peak output power for the 240 V configuration. Where: Output data (AC), row "Peak output power", 240 V column Sources366 VA The 208 V configuration prints a peak output power of 366 VA. [1] | [1] |
| Idle consumption | 0.026 W | Nighttime power consumption printed as 26 mW for the 240 V configuration. Where: Output data (AC), row "Nighttime power consumption", 240 V column SourcesConverted: 26 mW / 1000 = 0.026 W 0.012 W The 208 V configuration prints a nighttime power consumption of 12 mW. [1] | [1] |
| Continuous output | 0.38 kWConverted: 384 VA x power factor 1.0 / 1000 = 0.384 kW | Printed as 384 VA maximum continuous output power for the 240 V configuration; stored at the power factor setting of 1.0 the same document prints as default. Where: Output data (AC), row "Maximum continuous output power", 240 V column SourcesConverted: 384 VA x power factor 1.0 / 1000 = 0.384 kW 0.36 kW The 208 V configuration of the same SKU prints a maximum continuous output power of 360 VA. [1] | [1] |
| Mounting orientation | Under the PV module, horizontally bracket side up or vertically; never upside down | Printed as "The microinverters should be mounted beneath the modules, either horizontally bracketed side up or vertically oriented." and "Do not mount the microinverter upside down." in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 4.3 Mount the microinverters. Where: PDF page 18, section 4.3 Mount the microinverters | [2] |
| Max PV short circuit | 16 A | Printed as "Maximum input DC short-circuit current A 16" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC short-circuit current row. This is the microinverter input limit; the maximum module Isc is printed separately. Where: PDF page 42, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC short-circuit current row | [2] |
| Operating temperature | -40 to 65 °C / -40 to 149 °F converted | Printed as "Ambient temperature range –40°F to 149°F (–40°C to 65°C)" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Ambient temperature range row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source. Where: PDF page 43, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Ambient temperature range row | [2] [1] |
| Weighted efficiency | 96.5 % | Printed as "CEC weighted efficiency % 96.5 @ 240 VAC 96.5 @ 208 VAC" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, AC parameters, CEC weighted efficiency row. The same figure is printed at 240 VAC and 208 VAC. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source. Where: PDF page 43, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, AC parameters, CEC weighted efficiency row | [2] [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Continuous output
- 0.38 kW
- Battery voltage
- Not stated
- Solar input
- Not statedMPPT trackers Not statedMPPT range 43 to 60 V
- AC output
- 240 V split-phase (L-L) or 208 V single-phase (L-L)
- Warranty
- Not stated
- Size
- 1.12 L* (Calculated from published dimensions)W: 175 × H: 212 × D: 30.2 mm / W: 6.89 × H: 8.35 × D: 1.19 inWeight 1.1 kg / 2.4 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
0.026 against 0.021 W, the lowest documented for an inverter in the 0 to 1.5 kW output band (printed by the maker): Enphase IQ8M Microinverter IQ8M-72-2-US
Nighttime power consumption printed as 26 mW for the 240 V configuration.
Research pending, 0 points: Warranty term, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
How it worksCertificates
CA Rule 21 (UL 1741-SA)manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
CAN/CSA-C22.2 No. 107.1-01, 330manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
CAN/CSA-C22.3 No. 9manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
FCC Part 15 Class Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
ICES-0003 Class Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
IEEE 1547:2018 (UL 1741-SB 3rd Ed.)manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 62109-1manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 62109-2manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741 SBauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ8X-80-M-DOM-US {208V}": UL 1741 SB, certifying entity UL, certificate date 2026-05-13, CEC listing date 2024-10-01. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: May 13, 2026Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
CECauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- IQ8X-80-M-DOM-US
- Limitations
- Model IQ8X-80-M-DOM-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ8X-80-M-DOM-US {208V}"; "IQ8X-80-M-DOM-US {240V}", CEC listing date 2024-10-01. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Oct 1, 2024Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026)Open
Source details
Archived copy captured on 2026-10-01.
Location: PDF pages 39 and 42, specifications sections 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US and 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US
Retrieved Oct 1, 2026
Enphase's own installation and operation manual for the IQ8MC, IQ8AC, IQ8HC and IQ8X Microinverters (North America), captured 1 October 2026 from enphase.com; revision printed as IOM-00108-7.0-EN, September 2026. Its specifications sections name IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US/IQ8HC-72-M-DOM-US and IQ8X-80-M-US/IQ8X-80-M-DOM-US. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupIOM-00108-7.0-EN · 1.53 MBArchived copy, unaltered, kept as a record of what Enphase Energy published. Original address: https://enphase.com/download/iq8mc-iq8ac-iq8hc-and-iq8x-microinverters-installation-and-operation-manual. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 91a3ba3659327a4bb728da8e89aa431c8d73fd42ebe7a1a6343d89796b800b2e
Datasheets
- Enphase IQ8X Microinverter data sheetOpen
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.
Retrieved Sep 27, 2026
Archived copies
Archived copy of a document published by Enphase. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 0.61 MBArchived copy, unaltered, kept as a record of what Enphase published. Original address: https://enphase.com/download/iq8x-microinverter-data-sheet. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: cde78f0ca20acd3d0260ecd55dd696bc07f42964b72d44da53b3b26bb3bc7b7f
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Enphase IQ8X Microinverter data sheet
Archived copy of a document published by Enphase. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Enphase published. Original address: https://enphase.com/download/iq8x-microinverter-data-sheet. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: cde78f0ca20acd3d0260ecd55dd696bc07f42964b72d44da53b3b26bb3bc7b7f
Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026)
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Enphase Energy published. Original address: https://enphase.com/download/iq8mc-iq8ac-iq8hc-and-iq8x-microinverters-installation-and-operation-manual. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 91a3ba3659327a4bb728da8e89aa431c8d73fd42ebe7a1a6343d89796b800b2e
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- IQ8X-80-M-DOM-US
Manufacturer SKU IQ8X-80-M-DOM-US · US market
Observed Oct 11, 2026
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ8X-80-M-DOM-US {208V}": UL 1741 SB, certifying entity UL, certificate date 2026-05-13, CEC listing date 2024-10-01. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model IQ8X-80-M-DOM-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ8X-80-M-DOM-US {208V}"; "IQ8X-80-M-DOM-US {240V}", CEC listing date 2024-10-01. This is an equipment listing, not UL certification or complete-system approval.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 55 basis: Unknown missing: Warranty term needed Battery conversion efficiency needed criteria: key: certificates label: Certificates value: 31.5 unit: Unknown shown: UL 1741 SB +9 shown detail: Claimed state: claimed points: 14.2 ceiling: 45 weight: 45 share: 31.5 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [3] key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: 0.026 unit: Unknown shown: 0.03 W shown detail: Unknown state: documented points: 8.1 ceiling: 10 weight: 10 share: 80.8 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Enphase IQ8X Microinverter data sheet (Enphase · manufacturer · observed Sep 27, 2026)
- Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (Enphase Energy · manufacturer · IOM-00108-7.0-EN · observed Oct 1, 2026)
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
Sign in to report an error on this page
Similar products
All with a priceEnphase IQ8HC Microinverter IQ8HC-72-M-DOM-US
Duracell Power Center D350-M1A Microinverter
Enphase IQ8A Microinverter IQ8A-72-2-US
Enphase IQ8M Microinverter IQ8M-72-2-US