Charged ReviewsSaved 0Compare 0Login
Enphase
Microinverter

Enphase IQ8X Microinverter IQ8X-80-M-DOM-US

Key specs

Max PV voltage79.5 V
Weight1.1 kg / 2.4 lb converted
Efficiency97.3 %
Weighted efficiency96.5 %
Apparent power384 VA
Max PV short circuit16 A

All specifications

Identity

BrandEnphase · Website
ModelIQ8X-80-M-DOM-US
MarketUS
Manufacturer SKUIQ8X-80-M-DOM-US
About brandMicroinverters, home batteries and energy management systems.
SKU detail
locator: Key specifications table, column heading
conditions: Printed as a column heading alongside IQ8X-80-M-US in the IQ8X Microinverter data sheet.
Sources: [1]
FieldValueConditionsSource
GroundingNo grounding electrode conductor, equipment grounding conductor or grounded conductor (neutral) required; Class II double-insulated with ground fault protection; the AHJ may require bonding the mounting bracket to the racking
Printed as "do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductors (neutral)." and "The microinverter has a Class II double-insulated rating, including ground fault protection (GFP)." in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 2.2 Grounding considerations.
Where: PDF page 13, section 2.2 Grounding considerations
[2]
Weight1.1 kg / 2.4 lb converted
Printed as "Weight 2.42 lb (1.1 kg)" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Weight row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 44, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Weight row
[2] [1]
Voltage thd<5%
Printed as "Total harmonic distortion % <5" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, AC parameters, Total harmonic distortion row.
Where: PDF page 43, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, AC parameters, Total harmonic distortion row
[2]
ClearancesAt least 1.9 cm (3/4 in) between the roof and the microinverter and 1.3 cm (1/2 in) between the back of the PV module and the top of the microinverter; for a vertical mount, more than 30 cm (12 in) from the edges of the PV module
Printed as "Allow a minimum of ¾ in (1.9 cm) between the roof and the microinverter. Also, allow ½ in (1.3 cm) between the back of the PV module and the top of the microinverter." and "For a vertical mount, maintain a clearance of >12 in (30 cm) from the edges of the PV module" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 4.3 Mount the microinverters.
Where: PDF page 18, section 4.3 Mount the microinverters
[2]
DimensionsW 175 × H 212 × D 30.2 mm / W 6.89 × H 8.35 × D 1.19 in converted
Printed as "Dimensions (W × H × D) 6.9" × 8.3" × 1.2" (175 mm × 212 mm × 30.2 mm)" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Dimensions (W × H × D) row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 44, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Dimensions (W × H × D) row
[2] [1]
Efficiency97.3 %
Peak efficiency for the 240 V configuration.
Where: Output data (AC), row "Peak efficiency", 240 V column
Sources
97 %

The 208 V configuration prints a peak efficiency of 97.0%.

[1]
[1]
MPPT voltage43 to 60 V
Printed as "MPPT voltage range V 43–60" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, MPPT voltage range row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 42, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, MPPT voltage range row
[2] [1]
AC configuration240 V split-phase (L-L) or 208 V single-phase (L-L)
Printed as "8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications"; "Nominal grid voltage (L-L) V Split-phase (L-L), 180° @ 240 VAC Single-phase (L-L), 120° @ 208 VAC"; "do not require grounding electrode conductors (GEC), equipment grounding conductors (EGC), or grounded conductors (neutral)" in Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (PDF page 42; PDF page 13). Revised on 16 October 2026: Owner report 2026-10-16 (inverter filter AC output 120/240 V): the earlier text read as a 120/240 V unit; the manual prints a 240 V (or 208 V) output between the two lines only, with no 120 V output.
Where: PDF page 42; PDF page 13
Sources
208 V, single-phase (L-L), 120 degrees

The same row prints a 208 V single-phase configuration for this SKU.

[1]
[2]
Enclosure ratingNEMA Type 6
Printed as "NEMA Type 6/Outdoor".
Where: Mechanical data, row "Environmental category/UV exposure rating"
[1]
Max PV current10 A
Printed as "Maximum continuous operating DC A 10" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum continuous operating DC row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 42, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum continuous operating DC row
[2] [1]
Max PV voltage79.5 V
Printed as "Maximum input DC voltage V 79.5" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC voltage row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 42, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC voltage row
[2] [1]
Apparent power384 VA
Peak output power for the 240 V configuration.
Where: Output data (AC), row "Peak output power", 240 V column
Sources
366 VA

The 208 V configuration prints a peak output power of 366 VA.

[1]
[1]
Idle consumption0.026 W
Nighttime power consumption printed as 26 mW for the 240 V configuration.
Where: Output data (AC), row "Nighttime power consumption", 240 V column
Sources
Converted: 26 mW / 1000 = 0.026 W
0.012 W

The 208 V configuration prints a nighttime power consumption of 12 mW.

[1]
[1]
Continuous output0.38 kW
Converted: 384 VA x power factor 1.0 / 1000 = 0.384 kW
Printed as 384 VA maximum continuous output power for the 240 V configuration; stored at the power factor setting of 1.0 the same document prints as default.
Where: Output data (AC), row "Maximum continuous output power", 240 V column
Sources
Converted: 384 VA x power factor 1.0 / 1000 = 0.384 kW
0.36 kW

The 208 V configuration of the same SKU prints a maximum continuous output power of 360 VA.

[1]
[1]
Mounting orientationUnder the PV module, horizontally bracket side up or vertically; never upside down
Printed as "The microinverters should be mounted beneath the modules, either horizontally bracketed side up or vertically oriented." and "Do not mount the microinverter upside down." in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 4.3 Mount the microinverters.
Where: PDF page 18, section 4.3 Mount the microinverters
[2]
Max PV short circuit16 A
Printed as "Maximum input DC short-circuit current A 16" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC short-circuit current row. This is the microinverter input limit; the maximum module Isc is printed separately.
Where: PDF page 42, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, DC parameters, Maximum input DC short-circuit current row
[2]
Operating temperature-40 to 65 °C / -40 to 149 °F converted
Printed as "Ambient temperature range –40°F to 149°F (–40°C to 65°C)" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Ambient temperature range row. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 43, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, Features and specifications, Ambient temperature range row
[2] [1]
Weighted efficiency96.5 %
Printed as "CEC weighted efficiency % 96.5 @ 240 VAC 96.5 @ 208 VAC" in Enphase's IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters installation and operation manual (IOM-00108-7.0-EN, September 2026), section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, AC parameters, CEC weighted efficiency row. The same figure is printed at 240 VAC and 208 VAC. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Enphase (enphase.com), which stays listed as an additional source.
Where: PDF page 43, section 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US Microinverter specifications, AC parameters, CEC weighted efficiency row
[2] [1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
0.38 kW
Battery voltage
Not stated
Solar input
Not statedMPPT trackers Not statedMPPT range 43 to 60 V
AC output
240 V split-phase (L-L) or 208 V single-phase (L-L)
Warranty
Not stated
Size
1.12 L* (Calculated from published dimensions)W: 175 × H: 212 × D: 30.2 mm / W: 6.89 × H: 8.35 × D: 1.19 inWeight 1.1 kg / 2.4 lb

Evidence score

22/100Missing details55% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Warranty term needed; Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741 SB +9Claimed14.2 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[3]

Idle consumption0.03 W8.1 / 10.0

0.026 against 0.021 W, the lowest documented for an inverter in the 0 to 1.5 kW output band (printed by the maker): Enphase IQ8M Microinverter IQ8M-72-2-US

Nighttime power consumption printed as 26 mW for the 240 V configuration.

[1]

Research pending, 0 points: Warranty term, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
CA Rule 21 (UL 1741-SA)manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
CAN/CSA-C22.2 No. 107.1-01, 330manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
CAN/CSA-C22.3 No. 9manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
FCC Part 15 Class Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
ICES-0003 Class Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEEE 1547:2018 (UL 1741-SB 3rd Ed.)manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 62109-1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 62109-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Listed by Enphase in the Compliance row of Enphase's IQ8X Microinverter data sheet DSH-00185-8.0, printed for IQ8X-80-M-DOM-US alongside IQ8X-80-M-US. No certificate number, certification body or file number is printed beside it, and no issuer record was read.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741 SBauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ8X-80-M-DOM-US {208V}": UL 1741 SB, certifying entity UL, certificate date 2026-05-13, CEC listing date 2024-10-01. A state equipment list entry, not the certification body's own record.
Record detail
Issued: Not stated
Valid from: May 13, 2026
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[3]
CECauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
IQ8X-80-M-DOM-US
Limitations
Model IQ8X-80-M-DOM-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ8X-80-M-DOM-US {208V}"; "IQ8X-80-M-DOM-US {240V}", CEC listing date 2024-10-01. This is an equipment listing, not UL certification or complete-system approval.
Record detail
Issued: Not stated
Valid from: Oct 1, 2024
Expiry: Not stated
Issuer checked: Oct 11, 2026
Source
[3]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026)Official · Enphase Energy · Official installation manual · September 2026 · Web page
    Source details
    Revision
    IOM-00108-7.0-EN
    Revision date
    September 2026

    Archived copy captured on 2026-10-01.

    Location: PDF pages 39 and 42, specifications sections 8.3 IQ8HC-72-M-US/IQ8HC-72-M-DOM-US and 8.4 IQ8X-80-M-US/IQ8X-80-M-DOM-US

    Retrieved Oct 1, 2026

    Enphase's own installation and operation manual for the IQ8MC, IQ8AC, IQ8HC and IQ8X Microinverters (North America), captured 1 October 2026 from enphase.com; revision printed as IOM-00108-7.0-EN, September 2026. Its specifications sections name IQ8MC-72-M-US, IQ8AC-72-M-US, IQ8HC-72-M-US/IQ8HC-72-M-DOM-US and IQ8X-80-M-US/IQ8X-80-M-DOM-US. Manufacturer instructions, not independent tests.

    Archived copies

    Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupIOM-00108-7.0-EN · 1.53 MB

    Archived copy, unaltered, kept as a record of what Enphase Energy published. Original address: https://enphase.com/download/iq8mc-iq8ac-iq8hc-and-iq8x-microinverters-installation-and-operation-manual. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    47

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 91a3ba3659327a4bb728da8e89aa431c8d73fd42ebe7a1a6343d89796b800b2e

    Open
  • Datasheets

  • Enphase IQ8X Microinverter data sheetOfficial · Enphase · Official datasheet · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-28.

    Retrieved Sep 27, 2026

    Archived copies

    Archived copy of a document published by Enphase. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.61 MB

    Archived copy, unaltered, kept as a record of what Enphase published. Original address: https://enphase.com/download/iq8x-microinverter-data-sheet. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    5

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: cde78f0ca20acd3d0260ecd55dd696bc07f42964b72d44da53b3b26bb3bc7b7f

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Enphase IQ8X Microinverter data sheet

Archived copy of a document published by Enphase. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.61 MB

Archived copy, unaltered, kept as a record of what Enphase published. Original address: https://enphase.com/download/iq8x-microinverter-data-sheet. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
5

Embedded dates are file metadata, not independent proof of publication.

SHA-256: cde78f0ca20acd3d0260ecd55dd696bc07f42964b72d44da53b3b26bb3bc7b7f

Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026)

Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupIOM-00108-7.0-EN · 1.53 MB

Archived copy, unaltered, kept as a record of what Enphase Energy published. Original address: https://enphase.com/download/iq8mc-iq8ac-iq8hc-and-iq8x-microinverters-installation-and-operation-manual. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
47

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 91a3ba3659327a4bb728da8e89aa431c8d73fd42ebe7a1a6343d89796b800b2e

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
IQ8X-80-M-DOM-US

Manufacturer SKU IQ8X-80-M-DOM-US · US market

  1. Observed Oct 11, 2026

    UL 1741 SB: claimed

    Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ8X-80-M-DOM-US {208V}": UL 1741 SB, certifying entity UL, certificate date 2026-05-13, CEC listing date 2024-10-01. A state equipment list entry, not the certification body's own record.

    [3]

  2. Observed Oct 11, 2026

    CEC: claimed

    Product / system scope unresolved. Model IQ8X-80-M-DOM-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ8X-80-M-DOM-US {208V}"; "IQ8X-80-M-DOM-US {240V}", CEC listing date 2024-10-01. This is an equipment listing, not UL certification or complete-system approval.

    [3]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 55
basis: Unknown
missing:
Warranty term needed
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 31.5
unit: Unknown
shown: UL 1741 SB +9
shown detail: Claimed
state: claimed
points: 14.2
ceiling: 45
weight: 45
share: 31.5
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [3]
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 0.026
unit: Unknown
shown: 0.03 W
shown detail: Unknown
state: documented
points: 8.1
ceiling: 10
weight: 10
share: 80.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Enphase IQ8X Microinverter data sheet (Enphase · manufacturer · observed Sep 27, 2026)
  2. Enphase IQ8MC, IQ8AC, IQ8HC, and IQ8X Microinverters Installation and Operation Manual (IOM-00108-7.0-EN, September 2026) (Enphase Energy · manufacturer · IOM-00108-7.0-EN · observed Oct 1, 2026)
  3. CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details