Charged Reviews · Quick reference

Enphase IQ8+ Microinverter IQ8PLUS-72-2-US

Brand
Enphase
Model
IQ8PLUS-72-2-US
SKU / part number
IQ8PLUS-72-2-US [1] [2]
Category
Inverters

chargedreviews.com/inverters/enphase-iq8plus-72-2-us

AC output

Continuous output
?
Peak output
300 VA [2]
AC configuration
240 V (no neutral) [2]
AC output voltage
240 V [2]
AC frequency
60 Hz (nominal); extended frequency range 47 to 68 Hz [2]
Grid pass-through
?
Maximum output per leg
?

Battery

Battery voltage
?
Battery voltage range
16 to 58 V [2]
Maximum charge current
?
Maximum discharge current
?
Battery-only output
?
Maximum grid charging
?
Compatible batteries / BMS
?

PV input

PV array limit (connected)
?
PV input limit (converted)
?
Maximum PV voltage (Voc)
60 V [1]
MPPT voltage range
27 to 45 V [1]
MPPT trackers
?
String inputs per MPPT
?
PV current per MPPT
12 A [2]
PV short-circuit current
25 A [2]
PV startup voltage
?

Efficiency and modes

Peak efficiency
97.7 % [1]
CEC weighted efficiency
97 % [1]
Battery conversion efficiency
?
Grid / off-grid modes
?
Generator input
?
Transfer time
?
Idle consumption
0.025 W [2]
Parallel units
?

Communication and environment

Communications
Power line communication (PLC) [2]
Operating temperature
-40 to 60 °C / -40 to 140 °F converted [1]
Enclosure rating
NEMA Type 6 [1]
Operating noise
?

Mechanical

Dimensions
W 175 × H 212 × D 30.2 mm / W 6.89 × H 8.35 × D 1.19 in converted [1]
Weight
1.08 kg / 2.38 lb converted [1]

Installation (from the manual)

Protection

AC input breaker
?
AC output breaker
20 A maximum AC output overcurrent protection device [2]
Battery fuse or breaker
?
PV disconnect
?

Clearances and orientation

Installation clearances
Allow a minimum of 1.9 cm (3/4") between the roof and the microinverter.; Allow 1.3 cm (1/2") between the back of the PV module and the top of the microinverter.; For vertical mount, also maintain >30 cm (12") clearance from the edges of the PV module. [2]
Mounting orientation
Horizontally, bracket side up, or vertically; do not mount the microinverter upside down [2]

Grounding

Grounding and neutral-ground bonding
The DC circuit meets the requirements for ungrounded PV arrays in the NEC.; GFP is integrated into the class II double-insulated microinverter. [2]

Not in the manual: Torque, Conductors, Communication

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Enphase IQ8+ Microinverter IQ8PLUS-72-2-US · IQ8PLUS-72-2-US

Warranty

Warranty term?
Optional extension?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741?
UL 1741 SA?
UL 1741 SBVerified listed as of snapshot [3]
IEEE 1547Claimed present at observation [1]
CA Rule 21?
UL 9540?
FCC Part 15?
CA Rule 21 (UL 1741-SA)Claimed present at observation [1]
CAN/CSA-C22.2 NO. 107.1-01Claimed present at observation [1]
FCC Part 15 Class BClaimed present at observation [1]
ICES-0003 Class BClaimed present at observation [1]
UL 62109-1Claimed present at observation [1]
CECVerified listed as of snapshot [3]

Documents and sources

  1. IQ8 and IQ8+ Microinverters data sheet Manufacturer datasheet (PDF) · Revision 06/03/2026 · Checked Sep 19, 2026 https://enphase.com/download/iq8-and-iq8-microinverters-data-sheet
  2. IQ8, IQ8+, IQ8M, IQ8A, and IQ8H Microinverters installation and opearation manual Manufacturer installation manual (PDF) · Revision 07/09/2026 · Checked Sep 19, 2026 https://enphase.com/download/iq8-iq8-iq8m-iq8a-and-iq8h-microinverters-installation-and-opearation-manual
  3. CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) Government equipment list (spreadsheet) · Revision Data unchanged since October 1, 2026 · Revised Oct 1, 2026 · Checked Oct 10, 2026 https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=InvertersList

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/inverters/enphase-iq8plus-72-2-usSome links pay us a commission. That does not affect what we record.