Printed as "Peak output power VA 480" in the IQ8P Microinverter data sheet (DSH-00058-4.0), captured on September 25, 2026. No duration is printed; the figure is in VA, not W.
Printed as "Dimensions (H × W × D) 263.5 mm (10.4 in) × 194.3 mm (7.7 in) × 36.1 mm (1.4 in) (without mounting brackets)" in the IQ8P Microinverter data sheet (DSH-00058-4.0), captured on September 25, 2026.
Printed as "Peak efficiency % 97.6" in the IQ8P Microinverter data sheet (DSH-00058-4.0), captured on September 25, 2026. Manufacturer rating; test conditions are not stated.
Printed as "MPPT voltage range | 36–55 V" on page 1 of "IQ8P Microinverter data sheet", row "MPPT voltage range"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Nominal voltage (L-L) V 240, split-phase (L-L), 180°" in the IQ8P Microinverter data sheet (DSH-00058-4.0), captured on September 25, 2026.
Printed as "Max. continuous output power VA 475" in Enphase's IQ8P Microinverter installation and operation manual (IQ8P-72-2-US column) and as "Maximum continuous output power VA 475" in the IQ8P Microinverter data sheet (DSH-00058-4.0). Stored in VA as printed.
Printed as "Peak output power VA 480" in the IQ8P Microinverter data sheet (DSH-00058-4.0), captured on September 25, 2026. No duration is printed; the figure is in VA, not W.
Printed as "Peak efficiency % 97.6" in the IQ8P Microinverter data sheet (DSH-00058-4.0), captured on September 25, 2026. Manufacturer rating; test conditions are not stated.
Printed as "Nominal voltage (L-L) V 240, split-phase (L-L), 180°" in the IQ8P Microinverter data sheet (DSH-00058-4.0), captured on September 25, 2026.
Printed as "Max. continuous output power VA 475" in Enphase's IQ8P Microinverter installation and operation manual (IQ8P-72-2-US column) and as "Maximum continuous output power VA 475" in the IQ8P Microinverter data sheet (DSH-00058-4.0). Stored in VA as printed.
Printed as "CEC weighted efficiency | 97.5% | • Faster installation with simple two-" on page 1 of "IQ8P Microinverter data sheet", row "CEC weighted efficiency"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "MPPT voltage range | 36–55 V" on page 1 of "IQ8P Microinverter data sheet", row "MPPT voltage range"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Printed as "Dimensions (H × W × D) 263.5 mm (10.4 in) × 194.3 mm (7.7 in) × 36.1 mm (1.4 in) (without mounting brackets)" in the IQ8P Microinverter data sheet (DSH-00058-4.0), captured on September 25, 2026.
Printed as "Ambient temperature range | –40°C to 65°C (–40°F to 149°F)" on page 39 of "IQ8P Microinverter installation and operation manual", row "Ambient temperature range"; a manufacturer figure as printed, not an independent test. No value was taken from another model.
Location: instruction manual page 39, row "Ambient temperature range"
Documented
Published claims and calculations, not independent test results.
Documents
4 on file
WEB
IQ8P Microinverter data sheetOfficialEnphase EnergyOfficial datasheet
Certificate & compliance claims (6)
CA Rule 21 (UL 1741-SA)Manufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "CA Rule 21 (UL 1741-SA)" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 62109-1Manufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "UL 62109-1" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Enphase's own IQ8P Microinverter data sheet prints "IEEE 1547:2018 (UL 1741-SB 3rd Ed.)" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
FCC Part 15 Class BManufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "FCC Part 15 Class B" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
ICES-0003 Class BManufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "ICES-0003 Class B" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
CAN/CSA-C22.2 NO. 107.1-01Manufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "CAN/CSA-C22.2 NO. 107.1-01" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Listed by Enphase under "Data sheets" for product media 13076.
Location: IQ8P Microinverter data sheet
Retrieved
Original Enphase PDF preserved byte for byte, taken from the download list Enphase publishes for its own IQ8P store page at https://enphase.com/store/microinverters/iq8-series/iq8p-microinverter. It is a series document: it establishes what Enphase published for the IQ8P series on the access date, and it is attached only to catalog models whose own series code the document's title names. The revision is whatever was published at this URL on that date; no later revision was checked and no issuer record was read.
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
IQ8P Microinverter installation and operation manualOfficialEnphase EnergyOfficial installation manual
Source details
Revision
08/06/2026
Revision date
Not stated
Listed by Enphase under "Installation" for product media 13076.
Location: IQ8P Microinverter installation and operation manual
Retrieved
Original Enphase PDF preserved byte for byte, taken from the download list Enphase publishes for its own IQ8P store page at https://enphase.com/store/microinverters/iq8-series/iq8p-microinverter. It is a series document: it establishes what Enphase published for the IQ8P series on the access date, and it is attached only to catalog models whose own series code the document's title names. The revision is whatever was published at this URL on that date; no later revision was checked and no issuer record was read.
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Enphase Limited Warranty, U.S., IQ Microinverters and related products, effective on or after May 2, 2026 (WRTY-00148-1.0)OfficialEnphase EnergyOfficial warranty
Source details
Revision
WRTY-00148-1.0
Revision date
Not stated
Location: Covered Products Schedule; Sections 1 to 4
Retrieved
Recorded document/effective date: May 2, 2026
Enphase Energy's own U.S. limited warranty for IQ Microinverters, IQ Gateway, IQ Combiner, IQ System Controller and communication products, for systems activated on or after May 2, 2026, served as a PDF from enphase.com (linked from enphase.com/warranty/us) and captured on September 25, 2026. Its Covered Products Schedule sets the warranty period by exact SKU. Coverage is conditioned on registration and other terms in the document.
Archived copies
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Listed by Enphase under "Installation" for product media 13076.
Location: IQ8P Microinverter quick install guide
Retrieved
Original Enphase PDF preserved byte for byte, taken from the download list Enphase publishes for its own IQ8P store page at https://enphase.com/store/microinverters/iq8-series/iq8p-microinverter. It is a series document: it establishes what Enphase published for the IQ8P series on the access date, and it is attached only to catalog models whose own series code the document's title names. The revision is whatever was published at this URL on that date; no later revision was checked and no issuer record was read.
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Matched to the catalog record because the manufacturer's documented SKU for this product appears on this page and on no other page captured from this site.
Manufacturer-operated product page, captured byte for byte with a plain HTTPS GET and a desktop user agent. It establishes what the manufacturer published at this URL on the access date for this exact model: the specification table it shows, the page photo and the documents it links. Values rendered only by client-side scripts are not part of the capture. Marketing text, certification wording and stock state remain manufacturer claims that were not independently verified, and nothing on it was applied to any other model.
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
IQ8P Microinverter installation and operation manual
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Enphase Limited Warranty, U.S., IQ Microinverters and related products, effective on or after May 2, 2026 (WRTY-00148-1.0)
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Enphase U.S. limited warranty WRTY-00148-1.0 (effective for systems activated on or after May 2, 2026) lists this SKU in its "Enphase IQ8 Microinverters" row with the period "25 years from the Activation Date", captured on September 25, 2026. Coverage is conditioned on registration within 45 days and the document's other terms; systems activated before May 2, 2026 fall under earlier warranty versions.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
CertificatesUL 1741 SB +7Claimed14.2 / 45.0
Manufacturer claim; issuer verification pending. Applies to the exact inverter.
This is the best documented for an inverter, printed by the maker. 47 inverters share this value.
The Enphase U.S. limited warranty WRTY-00148-1.0 (effective for systems activated on or after May 2, 2026) lists this SKU in its "Enphase IQ8 Microinverters" row with the period "25 years from the Activation Date", captured on September 25, 2026. Coverage is conditioned on registration within 45 days and the document's other terms; systems activated before May 2, 2026 fall under earlier warranty versions.
Research pending, 0 points: Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
CA Rule 21 (UL 1741-SA)Product / system scope unresolvedClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "CA Rule 21 (UL 1741-SA)" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026.
UL 62109-1Product / system scope unresolvedClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "UL 62109-1" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026.
IEEE 1547:2018 (UL 1741-SB 3rd Ed.)Product / system scope unresolvedClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "IEEE 1547:2018 (UL 1741-SB 3rd Ed.)" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026.
FCC Part 15 Class BProduct / system scope unresolvedClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "FCC Part 15 Class B" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026.
ICES-0003 Class BProduct / system scope unresolvedClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "ICES-0003 Class B" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026.
CAN/CSA-C22.2 NO. 107.1-01Product / system scope unresolvedClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "CAN/CSA-C22.2 NO. 107.1-01" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026.
UL 1741 SBProduct / system scope unresolvedClaimedListed when checked
Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ8P-72-2-US {240V}": UL 1741 SB, certifying entity UL, certificate date 2026-05-13, CEC listing date 2024-02-01. A state equipment list entry, not the certification body's own record.
CECProduct / system scope unresolvedClaimedListed when checked
Model IQ8P-72-2-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ8P-72-2-US {240V}", CEC listing date 2024-02-01. This is an equipment listing, not UL certification or complete-system approval.
CA Rule 21 (UL 1741-SA)Manufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "CA Rule 21 (UL 1741-SA)" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
UL 62109-1Manufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "UL 62109-1" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
Enphase's own IQ8P Microinverter data sheet prints "IEEE 1547:2018 (UL 1741-SB 3rd Ed.)" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
FCC Part 15 Class BManufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "FCC Part 15 Class B" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
ICES-0003 Class BManufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "ICES-0003 Class B" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
CAN/CSA-C22.2 NO. 107.1-01Manufacturer claim · equipment listingClaimedListed when checked
Enphase's own IQ8P Microinverter data sheet prints "CAN/CSA-C22.2 NO. 107.1-01" in its Compliance, Certifications row for the model columns that include IQ8P-72-2-US. Recorded as the manufacturer prints it, captured on September 25, 2026; no issuer directory, file number or certificate was read in this pass, so the claim is not issuer-verified.
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
IQ8P-72-2-US
Manufacturer SKU IQ8P-72-2-US
Observed
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Enphase Energy, Inc. "IQ8P-72-2-US {240V}": UL 1741 SB, certifying entity UL, certificate date 2026-05-13, CEC listing date 2024-02-01. A state equipment list entry, not the certification body's own record.
Product / system scope unresolved. Model IQ8P-72-2-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ8P-72-2-US {240V}", CEC listing date 2024-02-01. This is an equipment listing, not UL certification or complete-system approval.