Image source: Duracell Power Center's own front-view drawing of the D700-M2 dual microinverter, under the heading "3.1.2 D700-M2: Terminals / Dimensions" in its microinverter installation manual (June 2024 file), with its AC lead and two pairs of DC leads. A drawing, not a photo. Figure from the manufacturer's document, page 6.Microinverter
Duracell Power Center D700-M2 Dual Microinverter
Key specs
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 2.6 kg / 5.7 lb converted | Printed as 2.60 in the Weight (kg) row, D700-M2 column, of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4. Read from rendered page 21 (the manual has no text layer). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Power Center (Duracell Power Center) (duracellpowercenter.com), which stays listed as an additional source. Where: PDF page 21, 10 Technical Data, Weight (kg) row, D700-M2 column | [2] [1] |
| Peak output | 700 VA | Printed as 700 in the Peak output power (VA) row, D700-M2 column, of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4. Read from rendered page 21 (the manual has no text layer). Where: PDF page 21, 10 Technical Data, Peak output power (VA) row, D700-M2 column | [2] |
| AC voltage | 208/183-229 V; 240/211-264 V | Printed as "208/183-229" and "240/211-264" in the Nominal output voltage/range (V) row of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4, one entry for all three models; a note says the voltage and frequency ranges can be extended beyond nominal if required by the utility. Read from rendered page 21 (the manual has no text layer). Where: PDF page 21, 10 Technical Data, Nominal output voltage/range (V) row, printed once for all three models | [2] |
| Dimensions | W 250 × H 170 × D 28 mm / W 9.84 × H 6.69 × D 1.1 in converted | Printed as "250 x 170 x 28" in the Dimensions (W×H×D mm) row, D700-M2 column, of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4. Read from rendered page 21 (the manual has no text layer). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Power Center (Duracell Power Center) (duracellpowercenter.com), which stays listed as an additional source. Where: PDF page 21, 10 Technical Data, Dimensions (WxHxD mm) row, D700-M2 column | [2] [1] |
| Communications | 2.4 GHz proprietary RF (Nordic) | Exact brochure wording. Where: Features, "Communication" | [1] |
| Efficiency | 96.7 % | Printed as 96.70% in the Peak inverter efficiency row of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4, one value for all three models. Read from rendered page 21 (the manual has no text layer). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Power Center (Duracell Power Center) (duracellpowercenter.com), which stays listed as an additional source. Where: PDF page 21, 10 Technical Data, Peak inverter efficiency row, printed once for all three models | [2] [1] |
| MPPT voltage | 33 to 48 V Check note | The brochure and the installation manual print different MPPT voltage figures. Duracell Power Center's microinverter brochure and spec sheet prints 16-60 V for the MPPT voltage range of the D350-M1, D700-M2 and D1500-M4; the Installation Manual's technical data prints 33~48 V as the peak power MPPT voltage range for the D700-M2 and 16~60 V as the operating voltage range. Printed as "33~48" in the Peak power MPPT voltage range (Vdc) row, D700-M2 column, of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4. The manual prints the 16~60 figure separately as the Operating voltage range (Vdc). Read from rendered page 21 (the manual has no text layer). Revised on 1 October 2026: The installation manual prints a peak power MPPT voltage range of 33 to 48 V for the D700-M2 and lists 16 to 60 V as the operating voltage range; the manual comes first in the owner's source order.Where: PDF page 21, 10 Technical Data, Peak power MPPT voltage range (Vdc) row, D700-M2 column Sources16 to 60 V Printed once for all three models as 16-60. [1] | [2] |
| AC frequency | 55-65 Hz | Printed as 55-65 in the Nominal frequency/range (Hz) row of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4; the label on PDF page 4 prints a nominal output frequency of 60 Hz. Read from rendered page 21 (the manual has no text layer). Where: PDF page 21, 10 Technical Data, Nominal frequency/range (Hz) row, printed once for all three models | [2] |
| AC configuration | Single-phase, 240 V or 208 V | The D700-M2 column prints 240 V (211-264 V) and 208 V (183-228 V) rows. Where: Output Data (AC), D700-M2 column, "Nominal output voltage(V)" | [1] |
| Enclosure rating | Outdoor NEMA 6 | Printed once for all three models; page 1 prints "NEMA 6 (IP67) enclosure". Where: Mechanical Data, "Enclosure rating" | [1] |
| Max PV voltage | 60 V | Printed as 60 in the Maximum input voltage (Vdc) row of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4, one value for all three models. Read from rendered page 21 (the manual has no text layer). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Power Center (Duracell Power Center) (duracellpowercenter.com), which stays listed as an additional source. Where: PDF page 21, 10 Technical Data, Maximum input voltage (Vdc) row, printed once for all three models | [2] [1] |
| AC output breaker | 20A branch: up to 4 units at 208V, 5 at 240V; 30A branch: up to 7 units at 208V, 8 at 240V | Printed as 4@208V and 5@240V in the Maximum units per 20A branch row and 7@208V and 8@240V in the Maximum units per 30A branch row, D700-M2 column, of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4. Appendix D describes a single 10 AWG trunk cable as one AC branch with a 30 Amp circuit protection rating. Read from rendered pages 21 and 27. Where: PDF page 21, 10 Technical Data, Maximum units per 20A branch and Maximum units per 30A branch row, D700-M2 column; PDF page 27, Appendix D: AC branch limit calculator | [2] |
| Apparent power | 696 VA | Printed in VA at 240 V; the D700-M2 group prints peak output 700 VA and maximum continuous output 696 VA, with 2.9 A and 8 units per 10 AWG branch at 240 V, and 3.35 A and 7 units at 208 V. Where: Output Data (AC), D700-M2 column, "Maximum continuous output power (VA)" | [1] |
| PV start voltage | 22 V | Printed as 22 in the Start-up voltage (Vdc) row of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4, one value for all three models. Read from rendered page 21 (the manual has no text layer). Where: PDF page 21, 10 Technical Data, Start-up voltage (Vdc) row, printed once for all three models | [2] |
| AC output wire size | 10 AWG trunk cable | Printed as "a single 10 AWG trunk cable as a single AC branch with a 30 Amp circuit protection rating" in Appendix D of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4. Read from rendered page 27. Where: PDF page 27, Appendix D: AC branch limit calculator, introduction | [2] |
| Night consumption | <50 mW | Printed as <50 in the Night time power consumption (mW) row of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4, one value for all three models. Read from rendered page 21 (the manual has no text layer). Where: PDF page 21, 10 Technical Data, Night time power consumption (mW) row, printed once for all three models | [2] |
| Mounting orientation | Hung on a screw fixed to the racking rail at the center of each panel or panel cluster, silver cover side facing the panel | Printed as "Hang the microinverter on the screw (see picture below), and tighten the screw(s).The silver cover side of the Microinverter should be facing the panel." after "Mark the approximate center of each panel / panel cluster on the frame." and "Fix the screw(s) on the rail." in Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4. Read from rendered page 13. Where: PDF page 13, 5.7 Installation: mounting the microinverter, steps 1 to 3 | [2] |
| Max PV input current | 11.5 A | Printed once for all three models; the maximum input short-circuit current is printed as 15 A. Where: Input Data (DC), "Maximum input current (A)" | [1] |
| Max PV short circuit | 15 A | Printed as 15 in the Max. input short circuit current (Adc), per port row of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4, one value for all three models. Read from rendered page 21 (the manual has no text layer). Where: PDF page 21, 10 Technical Data, Max. input short circuit current (Adc), per port row, printed once for all three models | [2] |
| Operating temperature | -40 to 65 °C / -40 to 149 °F converted | Printed as "-40 ~ +65" in the Ambient temperature range (°C) row of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4, one value for all three models. Read from rendered page 21 (the manual has no text layer). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Power Center (Duracell Power Center) (duracellpowercenter.com), which stays listed as an additional source. Where: PDF page 21, 10 Technical Data, Ambient temperature range (°C) row, printed once for all three models | [2] [1] |
| Other compliance claims | UL 1741, IEEE 1547, UL 1741 SA, UL 1741 SB (240 Vac), CA Rule 21 (240 Vac), CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C | Exact brochure wording; manufacturer claims with no certificate numbers or certification bodies printed. Where: Features, "Compliance" | [1] |
| Weighted efficiency | 96.5 % | Printed as 96.50% in the CEC weighted efficiency row of Duracell Power Center's Installation Manual for models D350-M1 / D700-M2 / D1500-M4, one value for all three models. Read from rendered page 21 (the manual has no text layer). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Power Center (Duracell Power Center) (duracellpowercenter.com), which stays listed as an additional source. Where: PDF page 21, 10 Technical Data, CEC weighted efficiency row, printed once for all three models | [2] [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- AC output (VA)
- 696 VA
- Battery voltage
- Not stated
- Solar input
- Not statedMPPT trackers Not statedMPPT range 33 to 48 V
- AC output
- Single-phase, 240 V or 208 V
- Warranty
- Not stated
- Size
- 1.19 L* (Calculated from published dimensions)W: 250 × H: 170 × D: 28 mm / W: 9.84 × H: 6.69 × D: 1.1 inWeight 2.6 kg / 5.7 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Research pending, 0 points: Warranty term, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
How it worksCertificates
CSA C22.2 No. 107.1-16manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- D350-M1; D700-M2; D1500-M4
- Limitations
- Printed in the Compliance row of the M Series brochure exactly as recorded. No certificate number, certification body or file number is printed, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
IEEE 1547manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- D350-M1; D700-M2; D1500-M4
- Limitations
- Printed in the Compliance row of the M Series brochure; the edition is not printed. No certificate or issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- D350-M1; D700-M2; D1500-M4
- Limitations
- Printed once in the Compliance row of the M Series brochure for all three models. No certificate number, certification body or file number is printed, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741 SAmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- D350-M1; D700-M2; D1500-M4
- Limitations
- Printed once in the Compliance row of the M Series brochure for all three models. No certificate number, certification body or file number is printed, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741 SB (240 Vac)manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- D350-M1; D700-M2; D1500-M4
- Limitations
- Printed as "UL 1741 SB (240 Vac)", limited to 240 Vac, in the Compliance row of the M Series brochure. No certificate number, certification body or file number is printed, and no issuer record was read.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741 SAauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- D700-M2
- Limitations
- Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Power Center "D700-M2 {240V}": UL 1741 SA, certifying entity CSA Group, certificate date 2022-05-13, CEC listing date 2022-09-12. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: May 13, 2022Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
UL 1741 SBauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- D700-M2
- Limitations
- Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Power Center "D700-M2 {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2023-03-17, CEC listing date 2022-09-12. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Mar 17, 2023Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
CECauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- D700-M2
- Limitations
- Model D700-M2 listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Power Center, as "D700-M2 {240V}", CEC listing date 2022-09-12. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Sep 12, 2022Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- Duracell Power Center Installation Manual, Models: D350-M1 / D700-M2 / D1500-M4Open
Source details
Archived copy captured on 2026-10-01.
Location: Every page header: Models: D350-M1 / D700-M2 / D1500-M4 Installation Manual; PDF page 21, 10 Technical Data
Retrieved Oct 1, 2026
Duracell Power Center's own installation manual for microinverter models D350-M1, D700-M2 and D1500-M4 (page header and technical data table), linked as MICROINVERTERS Installation Manual from duracellpowercenter.com/resources and captured 1 October 2026; no revision is printed (the file name carries the date 6-18-24). The pages are images without a text layer. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Duracell Power Center. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 14.51 MBArchived copy, unaltered, kept as a record of what Duracell Power Center published. Original address: https://duracellpowercenter.com/wp-content/uploads/2024/06/Duracell_Microinverter_Installation_Manual-6-18-24.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: c7a7b6725af3656a0ada233551e5dabcc147078a691e8ccaf5a080ea9be84795
Other documents
- Resources - Duracell Power Center (September 24, 2026 capture)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Power Center, MA Series and M Series document lists
Retrieved Sep 23, 2026
Duracell Power Center Resources page, captured on September 24, 2026. It links the datasheets and manuals cited here (checked in the page markup) and prints no product figures.
Archive and older revisions
Archive and older revisions1
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
- Duracell Power Center brochure and spec sheet: D350-M1 / D700-M2 / D1500-M4 Solar PV Microinverters (September 21, 2023 file)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Page 2 technical data table, D700-M2 column
Retrieved Sep 23, 2026
Two-page brochure and spec sheet linked from the Resources page as the M Series microinverter datasheet, archived on September 24, 2026; the file name carries the date 09-21-23. Its table sets D350-M1, D700-M2 and D1500-M4 side by side; the text layer runs the values of each row together, with values common to all three models printed once, so every figure read from it names the model column. Its compliance line is a manufacturer claim that no issuer record was read against.
Archived copies
Archived copy of a document published by Power Center (Duracell Power Center). Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 11.72 MBArchived copy, unaltered, kept as a record of what Power Center (Duracell Power Center) published. Original address: https://duracellpowercenter.com/wp-content/uploads/2023/10/Microinverter-Brochure-Spec-Sheet_09-21-23.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 2a2f224c7aa0d0c0dcc1dc8234f13de01304ba715f9670e407c5a83b6597aab6
Archived documents
Duracell Power Center brochure and spec sheet: D350-M1 / D700-M2 / D1500-M4 Solar PV Microinverters (September 21, 2023 file)
Archived copy of a document published by Power Center (Duracell Power Center). Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Power Center (Duracell Power Center) published. Original address: https://duracellpowercenter.com/wp-content/uploads/2023/10/Microinverter-Brochure-Spec-Sheet_09-21-23.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 2a2f224c7aa0d0c0dcc1dc8234f13de01304ba715f9670e407c5a83b6597aab6
Duracell Power Center Installation Manual, Models: D350-M1 / D700-M2 / D1500-M4
Archived copy of a document published by Duracell Power Center. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Duracell Power Center published. Original address: https://duracellpowercenter.com/wp-content/uploads/2024/06/Duracell_Microinverter_Installation_Manual-6-18-24.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: c7a7b6725af3656a0ada233551e5dabcc147078a691e8ccaf5a080ea9be84795
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- D700-M2
Manufacturer SKU D700-M2 · US market
Observed Oct 11, 2026
UL 1741 SA: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Power Center "D700-M2 {240V}": UL 1741 SA, certifying entity CSA Group, certificate date 2022-05-13, CEC listing date 2022-09-12. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Power Center "D700-M2 {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2023-03-17, CEC listing date 2022-09-12. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model D700-M2 listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Power Center, as "D700-M2 {240V}", CEC listing date 2022-09-12. This is an equipment listing, not UL certification or complete-system approval.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 45 basis: Unknown missing: Warranty term needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 31.5 unit: Unknown shown: UL 1741 SB (240 Vac) · UL 1741 +4 shown detail: Claimed state: claimed points: 14.2 ceiling: 45 weight: 45 share: 31.5 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [1] key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Duracell Power Center brochure and spec sheet: D350-M1 / D700-M2 / D1500-M4 Solar PV Microinverters (September 21, 2023 file) (Power Center (Duracell Power Center) · manufacturer · observed Sep 23, 2026)
- Duracell Power Center Installation Manual, Models: D350-M1 / D700-M2 / D1500-M4 (Duracell Power Center · manufacturer · observed Oct 1, 2026)
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)