Model number as printed in the DMX Power N Series page tables; the N Series Owner's Manual (Form 122187, 08/28/12), which the page links for this code, prints the 12/1800N and not the 12/1800AN code.
Converted: 42 lb x 0.45359237 kg/lb, rounded to 0.01 kg
Printed as 42 lb in the 12/1800N column (column 4 of 7) of the Weight row. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Printed as <5% beside the output waveform in the Output Wave Form row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Output voltage, printed as "120 VAC ± 5%" in the Output Voltage row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Converted: 15.5 x 16 x 7.5 in x 25.4 mm/in, rounded to 0.1 mm
Printed as 15.5 by 16 by 7.5 inches in the Dimensions column of the DMX Power page row for the 12/1800AN; the page names no axes, so the figures are kept in printed order as length, width and height. The N Series Owner's Manual (Form 122187, 08/28/12) prints no per-model dimensions.
Printed as "Up to 88%" in the inverter efficiency row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Output frequency, printed as "60 Hz ± 0.05%" in the Output Frequency row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Printed as "Pure Sine Wave" in the Output Wave Form row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Printed as <5% beside the output waveform in the Output Wave Form row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Output voltage, printed as "120 VAC ± 5%" in the Output Voltage row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Printed as "Up to 88%" in the inverter efficiency row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Output frequency, printed as "60 Hz ± 0.05%" in the Output Frequency row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Printed as "Pure Sine Wave" in the Output Wave Form row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Printed as 3960 W in the Surge column of the DMX Power page row for the 12/1800AN; the page names no surge duration. The N Series Owner's Manual (Form 122187, 08/28/12) prints no per-model peak power in watts.
Printed as 1800 W continuous on the DMX Power page row for the 12/1800AN; the N Series Owner's Manual (Form 122187, 08/28/12) prints 1800 watts continuous in the 12/1800N column (column 4 of 7) of the Output Power row, for the 12/1800N. 1800 W expressed in kW.
Location: Page Power & Output table; PDF page 13, 12 Specifications, General Specifications table
Converted
Battery operating voltage
10.5 to 20 V
Needs confirmation: DMX Power documents print two battery voltage ranges
The N Series Owner's Manual (Form 122187, 08/28/12) prints an input voltage of 10.5 to 20 VDC (shown); the DMX Power family page prints an operating range of 11 to 20 V for the 12/1800AN.
Input voltage, printed as "10.5 to 20" volts DC in the Input Voltage row, printed once for every model of the table. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N. The DMX Power page prints a different value, kept as an alternative; the owner's manual value is shown.
11 to 20 V
Printed as 11 to 20 V in the Operating Range column of the DMX Power page row for the 12/1800AN.
Converted: 42 lb x 0.45359237 kg/lb, rounded to 0.01 kg
Printed as 42 lb in the 12/1800N column (column 4 of 7) of the Weight row. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Converted: 15.5 x 16 x 7.5 in x 25.4 mm/in, rounded to 0.1 mm
Printed as 15.5 by 16 by 7.5 inches in the Dimensions column of the DMX Power page row for the 12/1800AN; the page names no axes, so the figures are kept in printed order as length, width and height. The N Series Owner's Manual (Form 122187, 08/28/12) prints no per-model dimensions.
Operating temperature, printed as 0 to 140 °F (-20 to 60 °C) in the Operating Temperature row, printed once for every model of the table; the Celsius figures are recorded. The manual prints the 12/1800N and not the 12/1800AN code, so the figure is read for the 12/1800N.
Location: PDF page 13, 12 Specifications, General Specifications table
Documented
Published claims and calculations, not independent test results.
Documents
2 on file
PDF
N Series Owner's Manual (Form 122187, 08/28/12) (November 2, 2026 capture)OfficialDMX PowerOfficial instruction manual
Source details
Revision
Form 122187 (08/28/12)
Revision date
Not stated
Linked from DMX Power's N Series page; captured 2026-11-02T08:19:13.625Z (archived copy).
Location: PDF page 13, Specifications
Retrieved
The N Series inverter Owner's Manual of the Sensata Technologies period (Form 122187, dated 08/28/12), which the page links as the manual of the 12/1800AN, linked from DMX Power's N Series page and fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 08:19:13.625 UTC). DMX Power bought the Magnum Energy, Dimensions and CSW product lines from Sensata Technologies in April 2025. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
DMX Power N Series inverter page (November 2, 2026 capture)OfficialDMX PowerOfficial product page
Source details
Revision
Not stated
Revision date
Not stated
DMX Power catalog page; captured 2026-11-02T06:13:52.241Z (archived copy).
Location: Models & Specifications tables
Retrieved
DMX Power's catalog page for the N Series inverters (formerly the Dimensions N Series), whose Models & Specifications tables list every N code with its status, fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:13:52.241 UTC). DMX Power bought the Magnum Energy, Dimensions and CSW product lines from Sensata Technologies in April 2025. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
N Series Owner's Manual (Form 122187, 08/28/12) (November 2, 2026 capture)
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5