5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 5 years" for the SEI Series; the manual prints no warranty term, and no conditions are stated.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: SEI Series front view from the dimension drawing in Dawnice's own SEI-8K-UP/10K-UP/12K-UP user manual, page 8; the three models share this drawing. Figure from the manufacturer's document, page 8.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 42 kg / 93 lb converted | Printed as "Weight 42kg"; the datasheet prints "42kg (92.59lb)". Where: Manual, 9. Datasheet (printed page 60), Basic data, Weight | [1] |
| MPPT count | 2 | Printed as "Num. of MPP Trackers 2". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, PV input, Num. of MPP Trackers | [1] |
| AC output | 10,000 W | Printed as "Rated Output Power 8800W 10,000W @240V 12000W @208V 10400W" in the manual (SEI-8K-UP, SEI-10K-UP and SEI-12K-UP columns; the 240 V and 208 V figures belong to the SEI-12K-UP); the SEI-10K-UP figure is 10,000W, also printed as "10,000W" in the datasheet. No separate continuous figure is printed, so this rated output is also recorded as the continuous output. Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Rated Output Power | [1] [2] |
| Peak output | 20,000VA | Printed as "Max. Peak Power 17,600VA 20,000VA 24,000VA" in the datasheet; the SEI-10K-UP figure is 20,000VA. The manual prints "2 times rated power" with no duration. Where: Datasheet, INVERTER OUTPUT, Max. Peak Power, SEI-10K-UP column | [2] |
| Max charge | 200 A | Printed as "Max. Hybrid Charging Current 200A" (PV and grid together). Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Battery, Max. Hybrid Charging Current | [1] |
| Dimensions | W 440 × H 750 × D 240 mm / W 17.3 × H 29.5 × D 9.45 in converted | Printed as "Dimensions 750*440*240mm"; the dimension drawing on page 8 shows 750 mm as the body height, 440 mm as the width and 240 mm as the depth (830 mm high with the mounting brackets, 499 mm wide with the handles). Where: Manual, 9. Datasheet (printed page 60), Basic data, Dimensions; 2.5 Dimension drawing (page 8) | [1] |
| Communications | RS485; CAN; USB; Dry contact; Wi-Fi (optional); GPRS (optional) | Printed as "Communication port RS485 / CAN / USB / Dry contact" and "External Modules (Optional) Wi-Fi / GPRS". Where: Manual, 9. Datasheet (printed page 60), Communication | [1] |
| Efficiency | 97.5 % | Printed as "Max Efficiency 97.5%". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Efficiency, Max Efficiency | [1] |
| MPPT voltage | 125 to 450 V | Printed as "MPPT Voltage Range 125-450Vdc/125-450Vdc". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, PV input, MPPT Voltage Range | [1] |
| Solar array | 5500W/5500W | Printed as "Max. PV array power 5500W/5500W 5500W/5500W 6600W/6600W" in the manual (SEI-8K-UP, SEI-10K-UP and SEI-12K-UP columns); the SEI-10K-UP figure is 5500W per tracker. The datasheet prints "5,500W+5,500W" across the SEI-8K-UP and SEI-10K-UP columns. Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, PV input, Max. PV array power | [1] [2] |
| AC frequency | 50/60Hz | Printed as "Rated AC Frequency 50/60Hz". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Rated AC Frequency | [1] |
| Max AC charge | 120 A | Printed as "Max. Grid Charging Current 120A"; the datasheet calls it "Max. Mains Charging Current 120A". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Battery, Max. Grid Charging Current | [1] |
| Max PV charge | 200 A | Printed as "Max. PV Charging Current 200A". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Battery, Max. PV Charging Current | [1] |
| Output waveform | Pure sine wave | Printed as "Waveform Pure Sine Wave". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Waveform | [1] |
| AC configuration | Split phase, 120/240 Vac; three phase 120/208 V (parallel) | Printed as "Rated Output Voltage 120/240Vac(Split-phase) 120/208V(Three-phase)" in the manual and "120/240Vac, single-phase / split-phase / three-phase(parallel)" in the datasheet. Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Rated Output Voltage | [1] [2] |
| Enclosure rating | IP65 | Printed as "Protection Degree IP65". Where: Manual, 9. Datasheet (printed page 60), Basic data, Protection Degree | [1] |
| Max PV current | 25 A | Printed as "Max. input current 25A+25A": 25 A for each of the two trackers. Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, PV input, Max. input current | [1] |
| Max PV voltage | 550 V | Printed as "Max. Voltage of Open Circuit 550Vdc+550Vdc": 550 V for each tracker. Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, PV input, Max. Voltage of Open Circuit | [1] |
| Nominal voltage | 48 V | Printed as "Rated Battery Voltage 48Vdc". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Battery, Rated Battery Voltage | [1] |
| Grid passthrough | 63 A | Printed as "Bypass phase current 63A". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Grid / Generator input, Bypass phase current | [1] |
| Max parallel units | 6 count | Printed as "Parallel capacity 6"; the datasheet prints "Num. of Parallel 1~6 units". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Parallel capacity | [1] |
| Certification claims | UL1741; IEEE1547.1-2020; CEC; RULE 21; HECO; FCC 15 class B; RoHS | The manual's Certified specifications rows list the safety standards UL1741, IEEE1547.1-2020, CEC, Rule 21 and HECO, EMC FCC 15 class B and RoHS (see the printed text). These are Dawnice's claims; no certificate was checked. Where: Manual, 9. Datasheet (printed page 60), Certified specifications | [1] |
| Continuous output | 10 kWConverted: 10000 W / 1000 = 10 kW | Printed as "Rated Output Power 8800W 10,000W @240V 12000W @208V 10400W" in the manual (SEI-8K-UP, SEI-10K-UP and SEI-12K-UP columns; the 240 V and 208 V figures belong to the SEI-12K-UP); the SEI-10K-UP figure is 10,000W, also printed as "10,000W" in the datasheet. The maker prints no separate continuous figure, so the rated output is recorded as continuous output. 10,000 W expressed in kW. Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Rated Output Power SourcesConverted: 10000 W / 1000 = 10 kW | [1] [2] |
| Battery voltage range | 40 to 60 V | Printed as "Voltage Range 40-60Vdc". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Battery, Voltage Range | [1] |
| Operating temperature | -25 to 60 °C / -13 to 140 °F converted | Printed as "Operating Temperature Range -25~60℃,>45℃ derated": output is derated above 45 °C. Where: Manual, 9. Datasheet (printed page 60), Basic data, Operating Temperature Range | [1] |
| Weighted efficiency | 96.5 % | Printed as "CEC Efficiency 96.5%". Where: Manual, 9. Datasheet (printed page 59), SEI-10K-UP column, Efficiency, CEC Efficiency | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 5 years" for the SEI Series; the manual prints no warranty term, and no conditions are stated.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 5 years | Printed as "Warranty 5 years" for the SEI Series; the manual prints no warranty term, and no conditions are stated. Where: Datasheet, GENERAL, Warranty | [2] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-21.
Location: 9. Datasheet (printed pages 59 and 60), SEI-10K-UP column; 2.5 Dimension drawing (page 8)
Retrieved Oct 21, 2026
Dawnice's own user manual for the SEI-8K-UP, SEI-10K-UP and SEI-12K-UP hybrid inverters (PDF), linked from Dawnice's US store (energydawnice.us) and served from the store's file CDN, captured on October 21, 2026. Manufacturer document, not an independent test.
Archived copy of a document published by Dawnice. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Dawnice published. Original address: https://cdn.shopify.com/s/files/1/0916/9980/6527/files/User-manual-Dawnice-Inverter-SEI-8K-UP-12K.pdf?v=1772264663. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 284049cd1b06978e77762c42e5f5b5e577856db3d2b2ae95b64b0db92f0db79b
Archived copy captured on 2026-10-21.
Location: Specification table, SEI-10K-UP column
Retrieved Oct 21, 2026
Dawnice's own SEI Series hybrid inverter datasheet (PDF), linked from Dawnice's US store (energydawnice.us) and served from the store's file CDN, captured on October 21, 2026. Manufacturer document, not an independent test.
Archived copy of a document published by Dawnice. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Dawnice published. Original address: https://cdn.shopify.com/s/files/1/0916/9980/6527/files/Dawnice-Hybrid-Inverter-Datasheet-SEI-8K-UP-12K.pdf?v=1772264663. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 10029ea144d2a70ec1ac8d3a42947b50ba5e86c6db14f5904f277e3a5b42b7c0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Dawnice. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Dawnice published. Original address: https://cdn.shopify.com/s/files/1/0916/9980/6527/files/User-manual-Dawnice-Inverter-SEI-8K-UP-12K.pdf?v=1772264663. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 284049cd1b06978e77762c42e5f5b5e577856db3d2b2ae95b64b0db92f0db79b
Archived copy of a document published by Dawnice. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Dawnice published. Original address: https://cdn.shopify.com/s/files/1/0916/9980/6527/files/Dawnice-Hybrid-Inverter-Datasheet-SEI-8K-UP-12K.pdf?v=1772264663. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 10029ea144d2a70ec1ac8d3a42947b50ba5e86c6db14f5904f277e3a5b42b7c0
No sourced accessories or replacement parts listed yet.
Manufacturer SKU SEI-10K-UP · US market
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 5 unit: Unknown shown: 5 years shown detail: Unknown state: documented points: 6 ceiling: 30 weight: 30 share: 20 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [2] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details