Image source: Chilicon Power CP-250E-60/72-208/240-MC4, the product photograph on page 1 of Chilicon Power's CP-250E datasheet (REV250 11.24.20), a single-SKU datasheet whose specification page names it "CP-250E-60-72-208/240-MC4". The yellow label on the unit prints "CP-250E-60/72-208/240-MC4" with its ratings, certification mark and barcode; cropped to the unit, without the page heading. Figure from the manufacturer's document, page 1.Chilicon Power CP-250E-60/72-208/240-MC4 microinverter
Key specs
All specifications
Show all 9 specifications
Identity
SKU detail
| Field | Value | Conditions | Source |
|---|---|---|---|
| AC voltage | 208 Vac; 240 Vac Check note | From the California Energy Commission list, not a maker document. This figure is printed on the California Energy Commission Solar Equipment List (data unchanged since October 1, 2026) as submitted for the listing. No maker document in the catalog prints it for this model yet. Listed as "208; 240" under "Nominal Voltage (Vac)" on the California Energy Commission list (data unchanged since October 1, 2026; downloaded October 11, 2026). One list row per nominal AC voltage option (2 rows).Where: Row 243, Nominal Voltage (Vac) | [1] |
| Night consumption | 0.06 W Check note | From the California Energy Commission list, not a maker document. This figure is printed on the California Energy Commission Solar Equipment List (data unchanged since October 1, 2026) as submitted for the listing. No maker document in the catalog prints it for this model yet. Listed as "0.06" under "Night Tare Loss (W)" on the California Energy Commission list (data unchanged since October 1, 2026; downloaded October 11, 2026). Solar Inverters list for the 240 Vac option.Where: Solar Inverters list, Row 244, Night Tare Loss (W) Sources0.02 W Listed as "0.02" under "Night Tare Loss (W)" on the California Energy Commission list (data unchanged since October 1, 2026; downloaded October 11, 2026). Solar Inverters list for the 208 Vac option. [1] | [1] |
| Continuous output | 0.289 kW Check note | From the California Energy Commission list, not a maker document. This figure is printed on the California Energy Commission Solar Equipment List (data unchanged since October 1, 2026) as submitted for the listing. No maker document in the catalog prints it for this model yet. Listed as "0.289" under "Maximum Continuous Output Power at Unity Power Factor (kW)" on the California Energy Commission list (data unchanged since October 1, 2026; downloaded October 11, 2026). Solar Inverters list for the 240 Vac option.Where: Solar Inverters list, Row 244, Maximum Continuous Output Power at Unity Power Factor (kW) Sources0.277 kW Listed as "0.277" under "Maximum Continuous Output Power at Unity Power Factor (kW)" on the California Energy Commission list (data unchanged since October 1, 2026; downloaded October 11, 2026). Solar Inverters list for the 208 Vac option. [1] | [1] |
| Weighted efficiency | 96 % Check note | From the California Energy Commission list, not a maker document. This figure is printed on the California Energy Commission Solar Equipment List (data unchanged since October 1, 2026) as submitted for the listing. No maker document in the catalog prints it for this model yet. Listed as "96" under "Weighted Efficiency (%)" on the California Energy Commission list (data unchanged since October 1, 2026; downloaded October 11, 2026). Solar Inverters list for the 240 Vac option. The list's CEC weighted efficiency.Where: Solar Inverters list, Row 244, Weighted Efficiency (%) Sources95.5 % Listed as "95.5" under "Weighted Efficiency (%)" on the California Energy Commission list (data unchanged since October 1, 2026; downloaded October 11, 2026). Solar Inverters list for the 208 Vac option. The list's CEC weighted efficiency. [1] | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Research pending, 0 points: Warranty term, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
How it worksCertificates
A green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.
CECauthority listing reportedlisted as of snapshot[1]
- Scope
- equipment listing
- Covered models
- CP-250E-60/72-208/240-MC4
- Limitations
- Model CP-250E-60/72-208/240-MC4 listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) under Chilicon Power, LLC, as "CP-250E-60/72-208/240-MC4 {208V}", "CP-250E-60/72-208/240-MC4 {240V}", grid support listing date 2017-12-15. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Dec 15, 2017Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [1]
UL 1741 SAauthority listing reportedlisted as of snapshot[2] [1]
- Scope
- equipment listing
- Covered models
- CP-250E-60/72-208/240-MC4
- Limitations
- On the CEC list as certified to UL 1741 SA. California Energy Commission official workbook checked November 6, 2026 Pacific (November 7 UTC). Solar_Inverters row 243, CP-250E-60/72-208/240-MC4 {208V}; Solar_Inverters row 244, CP-250E-60/72-208/240-MC4 {240V}. The SA8-SA13 flag (column E) and the certification group at Q:S were read together; a testing flag alone is insufficient. This reported claim is limited to SA8-SA13 and the voltage configurations in these rows. This is CEC-reported equipment evidence, not an issuer listing verification. No lab/file number, installation approval, regional transfer or complete-kit certification is established. Other maker claims and historical evidence remain separate. Earlier dated CEC observation retained below; any certifying-entity/date wording in that observation is the earlier CEC report, not a new issuer check: Listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) as Chilicon Power, LLC "CP-250E-60/72-208/240-MC4 {208V}": UL 1741 SA, certifying entity Intertek, certificate date 2020-01-08. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Jan 8, 2020Expiry: Not statedIssuer checked: Nov 6, 2026
- Source
- [2] [1]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Other documents
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026)Open
Source details
Archived copy captured on 2026-10-11.
Location: Model Number row
Retrieved Oct 10, 2026
Recorded document/effective date: Oct 1, 2026
California Energy Commission Solar Equipment List as downloaded on October 11, 2026 (its data key says updated October 1, 2026). It records that a listed model was submitted with the stated certification, certifying entity and dates; it is a state equipment list, not the certification body's own record, and absence from it says nothing about a product.
Matched on printed specifications
Not documented: Battery voltage range.
Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- CP-250E-60/72-208/240-MC4
Manufacturer SKU unknown · US market
Observed Nov 6, 2026
UL 1741 SA: claimed
Product / system scope unresolved. On the CEC list as certified to UL 1741 SA. California Energy Commission official workbook checked November 6, 2026 Pacific (November 7 UTC). Solar_Inverters row 243, CP-250E-60/72-208/240-MC4 {208V}; Solar_Inverters row 244, CP-250E-60/72-208/240-MC4 {240V}. The SA8-SA13 flag (column E) and the certification group at Q:S were read together; a testing flag alone is insufficient. This reported claim is limited to SA8-SA13 and the voltage configurations in these rows. This is CEC-reported equipment evidence, not an issuer listing verification. No lab/file number, installation approval, regional transfer or complete-kit certification is established. Other maker claims and historical evidence remain separate. Earlier dated CEC observation retained below; any certifying-entity/date wording in that observation is the earlier CEC report, not a new issuer check: Listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) as Chilicon Power, LLC "CP-250E-60/72-208/240-MC4 {208V}": UL 1741 SA, certifying entity Intertek, certificate date 2020-01-08. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model CP-250E-60/72-208/240-MC4 listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) under Chilicon Power, LLC, as "CP-250E-60/72-208/240-MC4 {208V}", "CP-250E-60/72-208/240-MC4 {240V}", grid support listing date 2017-12-15. This is an equipment listing, not UL certification or complete-system approval.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 45 basis: Unknown missing: Warranty term needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 28 unit: Unknown shown: UL 1741 SA · CEC shown detail: Claimed state: claimed points: 12.6 ceiling: 45 weight: 45 share: 28 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
- California Energy Commission InvertersList full official workbook, data 2026-10-21 (California Energy Commission · government equipment registry · Data unchanged since 2026-10-21 · observed Nov 6, 2026 · effective Oct 21, 2026)
Sign in to report an error on this page
Similar products
All with a priceEnphase IQ8+ Microinverter IQ8PLUS-72-M-US
Enphase IQ8M Microinverter IQ8M-72-2-US
Enphase IQ8A Microinverter IQ8A-72-2-US
Duracell Power Center D350-M1A Microinverter
* Missing details