5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "We provide a 5-year warranty service for materials and workmanship on this product."
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Callsun 12KW Split-Phase Pure Sine Wave Hybrid Solar Inverter (HS-LV12KNA), the first image Callsun's own US store page shows for it, captured on October 21, 2026.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 48 kg / 110 lb converted | Printed as "Weight 48kg"; the store page prints "Weight 48 kg". Where: Manual 10. Datasheet, Weight | [2] [1] |
| MPPT count | 2 | Printed as "Num. of MPPT Trackers 2". Where: Manual 10. Datasheet, Num. of MPPT Trackers | [2] [1] |
| AC output | 12,000 W | Printed as "@240V 12000W" and "@208V 10400W" in the HS-LV12KNA column (paired from the rendered page) and "Rated output power @240V 12000W/ @208V 10400W" on the store page; the 240 V figure is recorded. No separate continuous figure is printed, so this rated output is also recorded as the continuous output. Where: Manual 10. Datasheet, Rated Output Power, HS-LV12KNA column; store Specs tab | [2] [1] |
| Peak output | 1.5 times rated power (10s) | Printed as "Max. Peak Power 1.5 times rated power (10s)", one row for every model. Where: Manual 10. Datasheet, Max. Peak Power | [2] [1] |
| Max charge | 240 A | Printed as "Max. Hybrid Charging Current 240A" (paired from the rendered page); the store page prints "Max. hybrid charge current 240 A". Where: Manual 10. Datasheet, Max. Hybrid Charging Current | [2] [1] |
| Dimensions | W 440 × H 260 × L 840 mm / W 17.3 × H 10.2 × L 33.1 in converted | Printed as "840*440*260mm"; recorded in printed order. Where: Manual 10. Datasheet, Dimensions | [2] [1] |
| Communications | RS485; CAN; USB; Dry contact; Wi-Fi (optional module); GPRS (optional module) | Printed as "Communication port RS485 / CAN / USB / Dry contact" and "External Modules (Optional) Wi-Fi /GPRS". Where: Manual 10. Datasheet, Communication port; External Modules (Optional) | [2] |
| Efficiency | 97.5 % | Printed as "Max Efficiency 97.5%"; the store page prints "Max. efficiency of battery inverter 97.5%". Where: Manual 10. Datasheet, Max Efficiency | [2] [1] |
| MPPT voltage | 125 to 450 V | Printed as "MPPT Voltage Range 125-450Vdc/125-450Vdc" for the two inputs. Where: Manual 10. Datasheet, MPPT Voltage Range | [2] [1] |
| Solar array | 18 kWConverted: 9000 W + 9000 W = 18000 W; 18000 W / 1000 = 18 kW | Printed as "Max. PV array power 6600W/6600W 7500W/7500W 9000W/9000W"; the HS-LV12KNA column prints 9000 W for each of the two MPPT inputs (the store page prints "Max. input power 9000W+9000W"), 18,000 W in all. Where: Manual 10. Datasheet, Max. PV array power, HS-LV12KNA column SourcesConverted: 9000 W + 9000 W = 18000 W; 18000 W / 1000 = 18 kW | [2] [1] |
| AC frequency | 50/60Hz | Printed as "Rated AC Frequency 50/60Hz" (settable). Where: Manual 10. Datasheet, Rated AC Frequency | [2] |
| Max AC charge | 200 A | Printed as "Max. Grid Charging Current 200A"; the generator charging current is printed separately as 90A. The store page prints "Max. grid/generator charge current 200 A/90 A". Where: Manual 10. Datasheet, Max. Grid Charging Current | [2] [1] |
| Output waveform | Pure Sine Wave | Printed as "Waveform Pure Sine Wave". Where: Manual 10. Datasheet, Waveform | [2] |
| AC configuration | 120/240Vac (Split-phase); 120/208V (Three-phase) | Printed as "Rated Output Voltage 120/240Vac (Split-phase) 120/208V(Three-phase)". Where: Manual 10. Datasheet, Rated Output Voltage | [2] [1] |
| Enclosure rating | IP65 | Printed as "Protection Degree IP65". Where: Manual 10. Datasheet, Protection Degree | [2] [1] |
| Max PV current | 32 A | Printed as "Max. input current 32A+32A": 32 A for each of the two MPPT inputs. Where: Manual 10. Datasheet, Max. input current | [2] [1] |
| Max PV voltage | 550 V | Printed as "Max. Voltage of Open Circuit 550Vdc+550Vdc": 550 V for each MPPT input; the store page prints "550Vdc/550Vdc". Where: Manual 10. Datasheet, Max. Voltage of Open Circuit | [2] [1] |
| Nominal voltage | 48 V | Printed as "Rated Battery Voltage 48Vdc". Where: Manual 10. Datasheet, Rated Battery Voltage | [2] [1] |
| Grid passthrough | 200 A | Printed as "Continuous Grid Passthrough Current 200A" (paired from the rendered page). Where: Manual 10. Datasheet, Continuous Grid Passthrough Current | [2] |
| Max parallel units | 6 | Printed as "Parallel capacity 6". Where: Manual 10. Datasheet, Parallel capacity | [2] [1] |
| Certification claims | UL1741; IEEE1547.1-2020; CEC; Rule 21; HECO | The Safety standards row prints UL1741, IEEE1547.1-2020, CEC, Rule 21 and HECO (EMC: FCC 15 class B). A maker claim; no listing or certificate was checked. Where: Manual 10. Datasheet, Certified specifications, Safety standards | [2] [1] |
| Continuous output | 12 kWConverted: 12000 W / 1000 = 12 kW | Printed as "@240V 12000W" and "@208V 10400W" in the HS-LV12KNA column (paired from the rendered page) and "Rated output power @240V 12000W/ @208V 10400W" on the store page; the 240 V figure is recorded. The maker prints no separate continuous figure, so the rated output is recorded as continuous output. 12,000 W expressed in kW. Where: Manual 10. Datasheet, Rated Output Power, HS-LV12KNA column; store Specs tab SourcesConverted: 12000 W / 1000 = 12 kW | [2] [1] |
| Battery compatibility | Li-ion / Lead-Acid / User Defined | Printed as "Battery Type Li-ion / Lead-Acid / User Defined" (settable). Where: Manual 10. Datasheet, Battery Type | [2] |
| Max PV short circuit | 40 A | Printed as "Short current Isc 40A+40A": 40 A for each MPPT input. Where: Manual 10. Datasheet, Short current Isc | [2] |
| Battery voltage range | 40 to 60 V | Printed as "Voltage Range 40-60Vdc" (settable). Where: Manual 10. Datasheet, Voltage Range | [2] |
| Operating temperature | -25 to 60 °C / -13 to 140 °F converted | Printed as "-25~60°C, >45°C derated" in the manual. The store page prints "−25°C−65°C, >45°C derating"; the manual is recorded. Where: Manual 10. Datasheet, Operating Temperature Range | [2] |
| Weighted efficiency | 96.5 % | Printed as "CEC Efficiency 96.5%". Where: Manual 10. Datasheet, CEC Efficiency | [2] [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "We provide a 5-year warranty service for materials and workmanship on this product."
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 5 years | Printed as "We provide a 5-year warranty service for materials and workmanship on this product." Where: PDF page 62, 11. Warranty Policy | [2] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-21.
Location: Cover; printed pages 55 and 56 (PDF pages 58 and 59), 10. Datasheet; PDF page 62, 11. Warranty Policy
Retrieved Oct 21, 2026
Callsun's 62-page user manual for its HS-LV8KNA, HS-LV10KNA and HS-LV12KNA hybrid inverters, the file Callsun's 12KW store page links as its User Manual, served from cdn.shopify.com and captured on October 21, 2026; the pages print File version: V2.0. The PDF's text layer uses an unreadable font encoding, so the cover, the 10. Datasheet (printed pages 55 and 56, PDF pages 58 and 59) and the 11. Warranty Policy (PDF page 62) were read from the rendered pages, with an OCR reading used to check the quoted strings. The HS-LV12KNA column and the merged rows are cited. Manufacturer claims, not independent tests.
Archived copy of a document published by Callsun. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Callsun published. Original address: https://cdn.shopify.com/s/files/1/0651/5965/9688/files/CS-12KW_Solar_Hybrid_Inverter_User_Manual-V2.0.pdf?v=1791527674. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: fff8c219a988af2c23c20a61a4cb30f81f10f992134dde52943532ccb1952c0a
Archived copy captured on 2026-10-21.
Location: Product title; Key Features; Description; Specs tab
Retrieved Oct 21, 2026
Callsun's own US store page (callsunsolar.com), captured on October 21, 2026 with the paced research fetcher; the content is whatever the address served on that date. Manufacturer claims, not independent tests; the page carries no revision date.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Callsun. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Callsun published. Original address: https://cdn.shopify.com/s/files/1/0651/5965/9688/files/CS-12KW_Solar_Hybrid_Inverter_User_Manual-V2.0.pdf?v=1791527674. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: fff8c219a988af2c23c20a61a4cb30f81f10f992134dde52943532ccb1952c0a
No sourced accessories or replacement parts listed yet.
US market
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 5 unit: Unknown shown: 5 years shown detail: Unknown state: documented points: 6 ceiling: 30 weight: 30 share: 20 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [2] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details