Charged ReviewsSaved 0Compare 0Login
No photo yet
AIMS Power
Off-grid inverter

AIMS Power PWRIX200012SUL 2000W 12V Pure Sine Inverter with Transfer Switch

Key specs

Weight6.53 kg / 14.4 lb converted
Nominal voltage12 V
Efficiency90 %
Surge AC output4,000 W
AC voltage120 V
Continuous AC output2,000 W

All specifications

Identity

BrandAIMS Power · Website
ModelPWRIX200012SUL
MarketUS
Manufacturer SKUPWRIX200012SUL
About brandDesigns and sells off-grid and renewable energy equipment: DC to AC inverters, solar panels, deep-cycle batteries, solar charge controllers, cables, fuse kits and portable generators. AIMS Power says it was founded by Bruce de Jong, who built its first inverter in 2001.
SKU detail
locator: Store page Quick Comparison, SKU row; PDF page 1, manual cover
conditions: AIMS Power's store page prints SKU PWRIX200012SUL (first column of its Quick Comparison table, the page's own product); the instruction manual names it on its cover.
Sources: [1] [2]
FieldValueConditionsSource
GroundingGround terminal to the vehicle chassis, the boat's ground system or earth
The manual says to connect the rear panel ground terminal to the vehicle chassis in a vehicle, to the boat's ground system in a boat, and to earth in a fixed location.
Where: PDF page 6, Connection, 1. Grounding
[2]
Weight6.53 kg / 14.4 lb converted
Printed as 14.4 lb in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL; converted to kilograms. The store page prints the same unit weight.
Where: PDF page 11, Specifications, Net Weight row
Sources
Converted: 14.4 lb x 0.45359237 kg/lb, rounded to 0.01 kg
[2] [1]
Voltage thd<3%
Printed as Pure Sine Wave THD <3% in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL.
Where: PDF page 11, Specifications, Output Wave Form row
[2]
AC voltage120 VPrinted as "Output voltage 120VAC, 60HZ".
Where: Store page Specifications tab
[1]
ClearancesAllow 12 inches of space around the inverter to prevent objects from blocking the vents and to provide enough air to circulate.
Printed as "Allow 12 inches of space around the inverter to prevent objects from blocking the vents and to provide enough air to circulate".
Where: PDF page 5, Installation
[2]
DimensionsW 241.3 × H 88.9 × L 508 mm / W 9.5 × H 3.5 × L 20 in converted Check note
Needs confirmation: AIMS Power documents print two sets of dimensions. The PWRIX instruction manual prints 20 x 9.5 x 3.5 in (shown); the store page prints 21.5 x 9.5 x 3.8 in.
Printed only in inches, as 20 x 9.5 x 3.5 in in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL; converted to millimeters. A different value is printed elsewhere and kept as an alternative; the manual value is shown.
Where: PDF page 11, Specifications, Dimensions (LxWxH) row
Sources
Converted: 20 x 9.5 x 3.5 in x 25.4 mm/in, rounded to 0.1 mm
W 241.3 × H 96.5 × L 546.1 mm

Printed as 21.5 x 9.5 x 3.8 in (L x W x H) on the store page.

[1]
[2] [1]
Efficiency90 %
Printed as 90% in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL; the store page prints "Efficiency 86-90%" (a range).
Where: PDF page 11, Specifications, Efficiency row
[2] [1]
AC frequency60 HzPrinted as "Output voltage 120VAC, 60HZ".
Where: Store page Specifications tab
[1]
Output waveformPure sine wave
Printed as Pure Sine Wave THD <3% in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL.
Where: PDF page 11, Specifications, Output Wave Form row
[2]
Surge duration s0.04 s
Printed as "for 40 milsec"; 40 ms expressed in seconds.
Where: PDF page 11, Specifications, Surge Power Capacity row
Sources
Converted: 40 ms / 1000 = 0.04 s
[2]
Transfer time20 ms
Printed as 25 AMP <20msecs in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL; 20 ms is an upper bound, said so.
Where: PDF page 11, Specifications, Transfer Switch- Automatic Bypass row
[2]
Battery wire size2 AWG or larger
Printed as 2 AWG or larger in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL.
Where: PDF page 11, Specifications, Recommended Cable Size row
[2]
Nominal voltage12 V
Printed as 12V (10-16V) in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL.
Where: PDF page 11, Specifications, DC Input Voltage row
[2]
Surge AC output4,000 W
Printed as 4000W for 40 milsec in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL.
Where: PDF page 11, Specifications, Surge Power Capacity row
[2]
Grid passthrough25 A
Printed as 25 AMP in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL; the manual adds "The inverter's transfer switch is able to bypass the same amperage as the inverter".
Where: PDF page 11, Specifications, Transfer Switch- Automatic Bypass row
[2]
Certification claimsETL Listed to UL 458; CSA 22.2 NO 107.1
The manual cover prints "PWRIX120012SUL / PWRIX200012SUL INSTRUCTION MANUAL ETL Listed to UL 458 and CSA 22.2 NO 107.1". Manufacturer claims; no issuer directory was checked.
Where: PDF page 1, manual cover
[2]
Continuous output2 kW
Converted: 2000 W / 1000 = 2 kW
Printed as 2000W in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL; expressed in kW.
Where: PDF page 11, Specifications, Output Power row
Sources
Converted: 2000 W / 1000 = 2 kW
[2]
Mounting orientationAny orientation except upside downPrinted as "Do not mount the inverter upside down".
Where: PDF page 5, Installation
[2]
Continuous AC output2,000 W
Printed as 2000W in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL.
Where: PDF page 11, Specifications, Output Power row
[2]
Battery voltage range10 to 16 V
Printed as 12V (10-16V) in the second column of two of the specifications table, which heads its columns PWRIX120012120SUL and PWRIX200012120SUL.
Where: PDF page 11, Specifications, DC Input Voltage row
[2]
Operating temperature0 to 40 °C / 32 to 104 °F converted
The manual says the ambient temperature should be 32 to 104 °F (50 to 77 °F preferred); expressed in °C.
Where: PDF page 5, Installation
Sources
Converted: (32 °F - 32) x 5/9 = 0 °C; (104 °F - 32) x 5/9 = 40 °C
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
2 kW
Battery voltage
10 to 16 V
Solar input
Not statedMPPT trackers Not stated
AC output
120 V
Warranty
2 years
Size
10.9 L* (Calculated from published dimensions)W: 241.3 × H: 88.9 × L: 508 mm / W: 9.5 × H: 3.5 × L: 20 inWeight 6.53 kg / 14.4 lb

Evidence score

2/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term2 years2.4 / 30.0

2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "This product is covered by a full 2-year warranty from the date of purchase".

[2]

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Warranty term2 years
Printed as "This product is covered by a full 2-year warranty from the date of purchase".
Where: PDF page 12, Warranty
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • PWRIX120012SUL / PWRIX200012SUL Instruction Manual (022026) (November 2, 2026 capture)Official · AIMS Power · Official instruction manual · PDF
    Source details
    Revision
    022026
    Revision date
    Not stated

    Linked from the Manual tab of AIMS Power's product page; captured Nov 2, 2026 (archived copy).

    Location: PDF page 1, cover; PDF page 5, installation; PDF page 11, specifications; PDF page 12, warranty

    Retrieved Nov 2, 2026

    The PWRIX120012SUL and PWRIX200012SUL instruction manual (file dated 022026), linked from the Manual tab of AIMS Power's product page and fetched directly from www.aimscorp.net with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 10:44:48.117 UTC). Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup022026 · 1.17 MB

    Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2016/07/PWRIX-022026.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    12

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 221ac838be7091e9869315695ab49cc0fedaf750a847478523ec20168f8b2dcd

    Open
  • Other documents

  • AIMS Power product page for the PWRIX200012SUL (November 2, 2026 capture)Official · AIMS Power · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    AIMS Power store page; captured Nov 2, 2026 (archived copy).

    Location: Specifications tab; Additional information table; Manual tab

    Retrieved Nov 2, 2026

    AIMS Power's own store page for the PWRIX200012SUL on www.aimscorp.net (its Additional information, Specifications and Manual tabs), fetched directly with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 10:19:38.251 UTC). A product page, cited as such; manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

PWRIX120012SUL / PWRIX200012SUL Instruction Manual (022026) (November 2, 2026 capture)

Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup022026 · 1.17 MB

Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2016/07/PWRIX-022026.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
12

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 221ac838be7091e9869315695ab49cc0fedaf750a847478523ec20168f8b2dcd

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
PWRIX200012SUL

Manufacturer SKU PWRIX200012SUL · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 2
unit: Unknown
shown: 2 years
shown detail: Unknown
state: documented
points: 2.4
ceiling: 30
weight: 30
share: 8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. AIMS Power product page for the PWRIX200012SUL (November 2, 2026 capture) (AIMS Power · manufacturer · observed Nov 2, 2026)
  2. PWRIX120012SUL / PWRIX200012SUL Instruction Manual (022026) (November 2, 2026 capture) (AIMS Power · manufacturer · 022026 · observed Nov 2, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details