2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "This product is covered by a full 2-year warranty from the date of purchase".
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Grounding | Ground terminal to the vehicle chassis, the boat's ground system or earth | The manual says to connect the rear panel ground terminal to the vehicle chassis in a vehicle, to the boat's ground system in a boat, and to earth in a fixed location. Where: PDF page 5, Connection, 1. Grounding | [2] |
| AC voltage | 120 V | Printed as "Output voltage: 120 Volts ac". Where: Store page Specifications tab, output voltage | [1] |
| Clearances | Allow 12 inches of space around the inverter to prevent objects from blocking the vents and to provide enough air to circulate. | Printed as "Allow 12 inches of space around the inverter to prevent objects from blocking the vents and to provide enough air to circulate". Where: PDF page 4, Installation | [2] |
| Dimensions | W 140 × H 73.9 × L 213.1 mm / W 5.51 × H 2.91 × L 8.39 in converted | Printed only in inches as "Product size (L x W x H): 8.39″ x 5.51″ x 2.91″"; converted to millimeters. Where: Store page Specifications tab, size SourcesConverted: 8.39 x 5.51 x 2.91 in x 25.4 mm/in, rounded to 0.1 mm | [1] |
| Efficiency | 85 % | Printed as "Full load efficiency: 85%". Where: Store page Specifications tab, efficiency | [1] |
| AC frequency | 60 Hz | Printed as "Output frequency: 60 Hz". Where: Store page Specifications tab, output frequency | [1] |
| Output waveform | Pure sine wave | Printed as "Output wave form: pure sine wave". Where: Store page Specifications tab, output wave form | [1] |
| Nominal voltage | 12 V | The store page title prints "600W Pure Sine Power Inverter 12VDC to 120VAC". Where: Store page title | [1] |
| Surge AC output | 1,200 W | Printed as "Surge power capability (peak power): 1200 Watts"; no duration is printed. Where: Store page Specifications tab, surge power | [1] |
| Certification claims | ETL Listed to UL 458 & CSA 22.2 Standards | The manual cover prints "PWRI60012120S INSTRUCTION MANUAL ETL Listed to UL 458 & CSA 22.2 Standards". Manufacturer claims; no issuer directory was checked. Where: Manual cover | [2] |
| Continuous output | 0.6 kWConverted: 600 W / 1000 = 0.6 kW | Printed as "Continuous output power: 600 Watts"; expressed in kW. Where: Store page Specifications tab, continuous output power SourcesConverted: 600 W / 1000 = 0.6 kW | [1] |
| Mounting orientation | Any orientation except upside down | Printed as "Do not mount the inverter upside down". Where: PDF page 3, Installation | [2] |
| Continuous AC output | 600 W | Printed as "Continuous output power: 600 Watts". Where: Store page Specifications tab, continuous output power | [1] |
| Battery voltage range | 10 to 15 V | Printed as "DC input / operating voltage: 10 to 15 Volts". Where: Store page Specifications tab, DC input voltage range | [1] |
| Operating temperature | 0 to 40 °C / 32 to 104 °F converted | The manual says the ambient temperature should be 32 to 104 °F (50 to 77 °F preferred); expressed in °C. Where: PDF page 3, Installation SourcesConverted: (32 °F - 32) x 5/9 = 0 °C; (104 °F - 32) x 5/9 = 40 °C | [2] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "This product is covered by a full 2-year warranty from the date of purchase".
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 2 years | Printed as "This product is covered by a full 2-year warranty from the date of purchase". Where: PDF page 10, Warranty | [2] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Linked from the Manual tab of AIMS Power's product page; captured Nov 2, 2026 (archived copy).
Location: PDF page 1, cover; PDF pages 3 to 5, installation; PDF page 10, warranty
Retrieved Nov 2, 2026
The PWRI60012120S instruction manual (file dated 022026), linked from the Manual tab of AIMS Power's product page and fetched directly from www.aimscorp.net with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 10:44:34.221 UTC). Manufacturer claims, not independent tests.
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2011/02/PWRI60012120S-022026.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: e8a7b237d533167ccde0679b6ee7347dba1db069e485bb1f0d2cba829d352040
AIMS Power store page; captured Nov 2, 2026 (archived copy).
Location: Specifications tab; Additional information table; Manual tab
Retrieved Nov 2, 2026
AIMS Power's own store page for the PWRI60012120S on www.aimscorp.net (its Additional information, Specifications and Manual tabs), fetched directly with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 10:34:38.116 UTC). A product page, cited as such; manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2011/02/PWRI60012120S-022026.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: e8a7b237d533167ccde0679b6ee7347dba1db069e485bb1f0d2cba829d352040
No sourced accessories or replacement parts listed yet.
Manufacturer SKU PWRI60012120S · US market
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 2 unit: Unknown shown: 2 years shown detail: Unknown state: documented points: 2.4 ceiling: 30 weight: 30 share: 8 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [2] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details