2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "This product is covered by a full 2-year warranty from the date of purchase".
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 9.75 kg / 21.5 lb converted | Printed as 21.5 lbs in the PRM2KWN48120S column (column 2 of 2); converted to kilograms. The store page prints the same value. Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Weight row SourcesConverted: 21.5 lb x 0.45359237 kg/lb, rounded to 0.01 kg | [2] [1] |
| AC voltage | 120 V | Printed as 120Vac (120V ±3%) with no load for both models. Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Output voltage no load row | [2] |
| Dimensions | W 419.1 × H 88.9 × D 530.9 mm / W 16.5 × H 3.5 × D 20.9 in converted Check note | Needs confirmation: AIMS Power documents print two sets of dimensions. The rack mount inverter operation manual prints 16.5 x 20.9 x 3.5 in (W x D x H) (shown); the store page prints 16.5 x 17.5 x 3.75 in. Printed only in inches with the axes named (W, D, H) as 16.5 in wide, 20.9 in deep and 3.5 in high in the PRM2KWN48120S column (column 2 of 2); converted to millimeters. A different value is printed elsewhere and kept as an alternative; the primary document value is shown.Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Dimensions row SourcesConverted: 16.5 x 20.9 x 3.5 in x 25.4 mm/in, rounded to 0.1 mm W 419.1 × H 95.2 × D 444.5 mm Printed as 16.5 x 17.5 x 3.75 in (W x D x H) on the store page. [1] | [2] [1] |
| Efficiency | 92 % | Printed as 92% in the PRM2KWN48120S column (column 2 of 2). Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Output continuous efficiency row | [2] |
| AC frequency | 60 Hz | The manual says the frequency is fine-tuned at 60Hz at the factory; its specifications list a 60 Hz or 50 Hz selection. Where: PDF page 16, Operating procedure, step F | [2] |
| Output waveform | Pure sine wave | Printed as pure sine wave (single type). Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Output wave form row | [2] |
| AC input breaker | 20 A city power input circuit breaker | Printed as a city power input circuit breaker of 20A in the PRM2KWN48120S column (column 2 of 2). Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), City power input row | [2] |
| Ground wire size | 8 AWG | Printed as Earth 8 AWG in the explanation of the rear panel. Where: PDF page 15, Explanation of each section, item 14 | [2] |
| Surge duration s | 0.5 s | The manual says the maximum surge ability is 200% of the output capacity for 500 milliseconds; expressed in seconds. Where: PDF page 17, Troubleshooting SourcesConverted: 500 ms / 1000 = 0.5 s | [2] |
| AC output breaker | 20 A output circuit breaker | Printed as an output circuit breaker of 20A in the PRM2KWN48120S column (column 2 of 2). Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Overload protection row | [2] |
| Battery wire size | 10 AWG minimum | The manual's minimum cable size recommendations for negative 48Vdc list 10 AWG for the 2000 W model, with cables under 12 ft. Where: PDF page 16, Operating procedure, step C | [2] |
| Nominal voltage | 48 V | The table heading prints Negative DC 48V; the magnitude is recorded, said so. Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), table heading | [2] |
| Surge AC output | 4,000 W Check note | Needs confirmation: AIMS Power documents print two surge ratings. The rack mount inverter operation manual prints 4000 W (shown); the store page prints 6000 W. Printed as 4KW in the PRM2KWN48120S column (column 2 of 2); expressed in watts. A different value is printed elsewhere and kept as an alternative; the primary document value is shown.Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Surge rating row | [2] [1] |
| Communication ports | RS485 communication port (input DC voltage, output AC voltage, AC current and frequency) | The row prints an RS485 port, with RS232 for the 1000 W model. Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), RS485 Communication port row | [2] |
| Continuous output | 2 kW | Printed as 2KW in the PRM2KWN48120S column (column 2 of 2). Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Output power continuous row | [2] |
| Storage temperature | -35 to 68 °C / -31 to 154 °F converted | Printed as storage -35 to 68 °C in that row. Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Over temperature protection / return row | [2] |
| Continuous AC output | 2,000 W | Printed as 2KW in the PRM2KWN48120S column (column 2 of 2); expressed in watts. Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), Output power continuous row SourcesConverted: 2 kW x 1000 = 2000 W | [2] |
| Battery voltage range | 41 to 60 V | Printed as DC -41V to -60V, a negative 48 V DC input (positive ground); the magnitudes are recorded, said so. The store page prints the same range. Where: PDF page 3, Specifications (1000W, 2000W Negative DC 48V 120Vac), DC input voltage (negative) row | [2] [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "This product is covered by a full 2-year warranty from the date of purchase".
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 2 years | Printed as "This product is covered by a full 2-year warranty from the date of purchase". Where: PDF page 20, Warranty | [2] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Linked from the Manual tab of AIMS Power's product page; captured Nov 2, 2026 (archived copy).
Location: PDF pages 3 and 4, specifications; PDF page 15, earth wire; PDF page 16, operating procedure; PDF page 17, troubleshooting; PDF page 20, warranty
Retrieved Nov 2, 2026
The negative 48 V DC rack mount inverter operation manual for the PRM1KWN48120S, PRM2KWN48120S, PRM3KWN48120S and PRM5KWN48120S (file dated 022026), linked from the Manual tab of AIMS Power's product page and fetched directly from www.aimscorp.net with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 12:49:45.979 UTC). Manufacturer claims, not independent tests.
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2025/02/AIMS-48Vdc-RackMount-022026.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: fb882b1bd1fdda4a66fad636da9718448f3ca397cd7b8539ec11dd285cd35e52
AIMS Power store page; captured Nov 2, 2026 (archived copy).
Location: Specifications tab; Additional information table; Manual tab
Retrieved Nov 2, 2026
AIMS Power's own store page for the PRM2KWN48120S on www.aimscorp.net (its Additional information, Specifications and Manual tabs), fetched directly with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 09:52:59.688 UTC). A product page, cited as such; manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2025/02/AIMS-48Vdc-RackMount-022026.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: fb882b1bd1fdda4a66fad636da9718448f3ca397cd7b8539ec11dd285cd35e52
No sourced accessories or replacement parts listed yet.
Manufacturer SKU PRM2KWN48120S
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 2 unit: Unknown shown: 2 years shown detail: Unknown state: documented points: 2.4 ceiling: 30 weight: 30 share: 8 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [2] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details