Charged ReviewsSaved 0Compare 0Login
No photo yet
AIMS Power
Off-grid inverter

AIMS Power PILF30W12V120V 3000W 12V Low Frequency Pure Sine Power Inverter

Key specs

Weight26 kg / 57 lb converted Check note
Nominal voltage12 V
Efficiency88 %
Surge AC output9,000 W
AC voltage120 V
Continuous AC output3,000 W

All specifications

Identity

BrandAIMS Power · Website
ModelPILF30W12V120V
MarketUnknown
Manufacturer SKUPILF30W12V120V
About brandDesigns and sells off-grid and renewable energy equipment: DC to AC inverters, solar panels, deep-cycle batteries, solar charge controllers, cables, fuse kits and portable generators. AIMS Power says it was founded by Bruce de Jong, who built its first inverter in 2001.
SKU detail
locator: Store page Quick Comparison, SKU row; PDF page 15, 3.3 DC Wiring & Fusing table
conditions: AIMS Power's store page prints SKU PILF30W12V120V (first column of its Quick Comparison table, the page's own product); the PILF Series manual prints the PILF30W12V120V in its DC wiring table.
Sources: [1] [2]
FieldValueConditionsSource
Weight26 kg / 57 lb converted Check note
Needs confirmation: AIMS Power documents print two weights. The PILF Series manual prints 57.3 lb (26Kg) for this model's column (shown); the store page prints 57 lb.
Printed as 26Kg 57.3lbs in the 3012 column (column 6 of 7) of the spec sheet, whose columns are headed 0612, 1012, 1512, 2012, 2412, 3012, 4012; the kilogram figure is recorded. A different value is printed elsewhere and kept as an alternative; the manual value is shown.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Inverter Weight row
Sources
25.85 kg

Printed as 57 lb on the store page.

[1]
[2] [1]
Voltage thdTypically <3%, max 10% under full linear load
Printed in the THD row for every model as typically under 3% and at most 10% under full linear load.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, THD row
[2]
AC voltage120 V
The DC wiring table row for the PILF30W12V120V prints its specifications as 3000W, 120Vac, 12Vdc; the spec sheet prints "Nominal Output Voltage 120Vac (Single Phase) or 120/240Vac (Split Phase)".
Where: PDF page 15, 3.3 DC Wiring & Fusing table, PILF30W12V120V row
[2]
ClearancesWe recommend 1 foot of clearance around the inverter for air flow.
Printed as "We recommend 1 foot of clearance around the inverter for air flow".
Where: PDF page 3, 1.1 General Safety Precautions
[2]
DimensionsW 344 × H 184 × L 480 mm / W 13.5 × H 7.24 × L 18.9 in converted Check note
Needs confirmation: AIMS Power documents print two sets of dimensions. The PILF Series manual prints 480*344*184mm (18.9*13.5*7.2 in) for the PILF 2000-3000W models (shown); the store page prints 19 x 13.75 x 7.25 in for the PILF30W12V120V.
Printed as 480*344*184mm (18.9*13.5*7.2 in) in the PILF 2000-3000W column of the Inverter Dimensions (L*W*H) row. A different value is printed elsewhere and kept as an alternative; the manual value is shown.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Inverter Dimensions (L*W*H) row, PILF 2000-3000W column
Sources
W 349.2 × H 184.1 × L 482.6 mm

Printed as 19 x 13.75 x 7.25 in (L x W x H) on the store page.

[1]
[2] [1]
Efficiency88 %
Printed as "Nominal Efficiency Up to 88%" for every model (an upper bound, said so), and the same on the store page; the manual's 2.5.1 Inverter section also says "The Peak efficiency of the PILF series is 92%" (peak, not nominal).
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Nominal Efficiency row
[2] [1]
AC frequency50/60 Hz ± 0.3 Hz
Printed as "Output Frequency 50/60Hz ± 0.3Hz" for every model.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Output Frequency row
[2]
Output waveformPure sine wave
Printed as "Output Waveform Pure Sine wave" for every model.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Output Waveform row
[2]
Ground wire size8 AWG or greater copper
Printed as "Connect an 8 AWG gauge or greater copper wire between the grounding terminal on the inverter and the earth grounding system or the vehicle chassis".
Where: PDF page 17, 3.5 Grounding
[2]
Surge duration s20 s
The surge row is headed "Surge Rating(20s)".
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Surge Rating(20s) row
[2]
Battery wire size1/0 AWG for DC cable runs up to 1.5 m (60 in); 1/0 AWG for 1.5 to 3.0 m (60 to 120 in)
Read from the PILF30W12V120V row of the manual's DC wiring table, which gives the minimum cable for 5% voltage drop at full output, at 25 °C (77 °F), by estimated cable length.
Where: PDF page 15, 3.3 DC Wiring & Fusing table, PILF30W12V120V row
[2]
Nominal voltage12 V
Printed as "DC Input Nominal Input Voltage 12.0Vdc".
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, DC Input, Nominal Input Voltage row
[2]
Surge AC output9,000 W
Printed as 9000 in the 3012 column (column 6 of 7) of the spec sheet, whose columns are headed 0612, 1012, 1512, 2012, 2412, 3012, 4012, for 20 seconds; the store page prints "Surge Rating(20s) Watt 9000".
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Surge Rating(20s) row
[2] [1]
Battery protection300 A fuse
Read from the PILF30W12V120V row of the manual's DC wiring table (maximum fusing guide); the table notes that the fuse size must be smaller than the maximum cable rating, but large enough for full inverter performance.
Where: PDF page 15, 3.3 DC Wiring & Fusing table, PILF30W12V120V row
[2]
Continuous output3 kW
Converted: 3000 W / 1000 = 3 kW
Printed as 3000 in the 3012 column (column 6 of 7) of the spec sheet, whose columns are headed 0612, 1012, 1512, 2012, 2412, 3012, 4012, and as "Continuous Power Watt 3000" on the store page; 3000 W expressed in kW.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Continuous Power row; store page Specifications tab
Sources
Converted: 3000 W / 1000 = 3 kW
[2] [1]
Mounting orientationAny orientation except upside down
Printed as "Do not mount upside down (top side facing down)".
Where: PDF page 23, Troubleshooting, Common FAQs
[2]
Standby consumption2.5 W
Printed as under 2.5 W in search mode with Power Saver on (an upper bound, said so), for every model.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Idle Consumption-Search Mode row
[2]
Storage temperature-40 to 70 °C / -40 to 158 °F convertedPrinted in Celsius as -40 to 70 °C for storage in 3.2 Location.
Where: PDF page 15, 3.2 Location
[2]
Continuous AC output3,000 W
Printed as 3000 in the 3012 column (column 6 of 7) of the spec sheet, whose columns are headed 0612, 1012, 1512, 2012, 2412, 3012, 4012.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Continuous Power row
[2] [1]
Battery terminal torque12.5 to 20.5 N·m
Printed as a DC terminal torque range of 12.5 to 20.5 N·m (9.25 to 15.19 lb-ft), with 17 N·m (12.6 lb-ft) suggested.
Where: PDF page 16, 3.3 DC Wiring & Fusing, warning
[2]
Operating temperature-10 to 40 °C / 14 to 104 °F convertedPrinted in Celsius as -10 to 40 °C for operation in 3.2 Location.
Where: PDF page 15, 3.2 Location
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
3 kW
Battery voltage
12 V
Solar input
Not statedMPPT trackers Not stated
AC output
120 V
Warranty
Not stated
Size
30.38 L* (Calculated from published dimensions)W: 344 × H: 184 × L: 480 mm / W: 13.5 × H: 7.24 × L: 18.9 inWeight 26 kg / 57 lb

Evidence score

Research pending0% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • PILF Series DC to AC Power Inverter User's Manual (071725) (November 2, 2026 capture)Official · AIMS Power · Official instruction manual · PDF
    Source details
    Revision
    071725
    Revision date
    Not stated

    Linked from the Manual tab of AIMS Power's product page; captured Nov 2, 2026 (archived copy).

    Location: PDF page 15, 3.3 DC Wiring & Fusing; PDF pages 16 and 17, AC wiring and grounding; PDF page 25, Appendix 1 - PILF Series Spec Sheet

    Retrieved Nov 2, 2026

    The PILF Series user's manual (file dated 071725), linked from the Manual tab of AIMS Power's product page and fetched directly from www.aimscorp.net with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 10:45:31.538 UTC). Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup071725 · 5.42 MB

    Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2025/07/AIMS-PILF-MAN-071725.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    27

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 57a4f31d2ed1a852577c909b67af49a1326445be6759409e6cc3cc6c5759d9c6

    Open
  • Other documents

  • AIMS Power product page for the PILF30W12V120V (November 2, 2026 capture)Official · AIMS Power · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    AIMS Power store page; captured Nov 2, 2026 (archived copy).

    Location: Specifications tab; Additional information table; Manual tab

    Retrieved Nov 2, 2026

    AIMS Power's own store page for the PILF30W12V120V on www.aimscorp.net (its Additional information, Specifications and Manual tabs), fetched directly with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 09:50:43.499 UTC). A product page, cited as such; manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

PILF Series DC to AC Power Inverter User's Manual (071725) (November 2, 2026 capture)

Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup071725 · 5.42 MB

Archived copy, unaltered, kept as a record of what AIMS Power published. Original address: https://www.aimscorp.net/wp-content/uploads/2025/07/AIMS-PILF-MAN-071725.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
27

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 57a4f31d2ed1a852577c909b67af49a1326445be6759409e6cc3cc6c5759d9c6

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
PILF30W12V120V

Manufacturer SKU PILF30W12V120V

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 0
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. AIMS Power product page for the PILF30W12V120V (November 2, 2026 capture) (AIMS Power · manufacturer · observed Nov 2, 2026)
  2. PILF Series DC to AC Power Inverter User's Manual (071725) (November 2, 2026 capture) (AIMS Power · manufacturer · 071725 · observed Nov 2, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details