About brandDesigns and sells off-grid and renewable energy equipment: DC to AC inverters, solar panels, deep-cycle batteries, solar charge controllers, cables, fuse kits and portable generators. AIMS Power says it was founded by Bruce de Jong, who built its first inverter in 2001.
SKU detail
locator: Store page Quick Comparison, SKU row; PDF page 15, 3.3 DC Wiring & Fusing table
conditions: AIMS Power's store page prints SKU PILF30W12V120V (first column of its Quick Comparison table, the page's own product); the PILF Series manual prints the PILF30W12V120V in its DC wiring table.
Needs confirmation: AIMS Power documents print two weights. The PILF Series manual prints 57.3 lb (26Kg) for this model's column (shown); the store page prints 57 lb.
Printed as 26Kg 57.3lbs in the 3012 column (column 6 of 7) of the spec sheet, whose columns are headed 0612, 1012, 1512, 2012, 2412, 3012, 4012; the kilogram figure is recorded. A different value is printed elsewhere and kept as an alternative; the manual value is shown.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Inverter Weight row
The DC wiring table row for the PILF30W12V120V prints its specifications as 3000W, 120Vac, 12Vdc; the spec sheet prints "Nominal Output Voltage 120Vac (Single Phase) or 120/240Vac (Split Phase)".
Where: PDF page 15, 3.3 DC Wiring & Fusing table, PILF30W12V120V row
W 344 × H 184 × L 480 mm / W 13.5 × H 7.24 × L 18.9 in convertedCheck note
Needs confirmation: AIMS Power documents print two sets of dimensions. The PILF Series manual prints 480*344*184mm (18.9*13.5*7.2 in) for the PILF 2000-3000W models (shown); the store page prints 19 x 13.75 x 7.25 in for the PILF30W12V120V.
Printed as 480*344*184mm (18.9*13.5*7.2 in) in the PILF 2000-3000W column of the Inverter Dimensions (L*W*H) row. A different value is printed elsewhere and kept as an alternative; the manual value is shown.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Inverter Dimensions (L*W*H) row, PILF 2000-3000W column
Sources
W 349.2 × H 184.1 × L 482.6 mm
Printed as 19 x 13.75 x 7.25 in (L x W x H) on the store page.
Printed as "Nominal Efficiency Up to 88%" for every model (an upper bound, said so), and the same on the store page; the manual's 2.5.1 Inverter section also says "The Peak efficiency of the PILF series is 92%" (peak, not nominal).
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Nominal Efficiency row
Printed as "Connect an 8 AWG gauge or greater copper wire between the grounding terminal on the inverter and the earth grounding system or the vehicle chassis".
1/0 AWG for DC cable runs up to 1.5 m (60 in); 1/0 AWG for 1.5 to 3.0 m (60 to 120 in)
Read from the PILF30W12V120V row of the manual's DC wiring table, which gives the minimum cable for 5% voltage drop at full output, at 25 °C (77 °F), by estimated cable length.
Where: PDF page 15, 3.3 DC Wiring & Fusing table, PILF30W12V120V row
Printed as 9000 in the 3012 column (column 6 of 7) of the spec sheet, whose columns are headed 0612, 1012, 1512, 2012, 2412, 3012, 4012, for 20 seconds; the store page prints "Surge Rating(20s) Watt 9000".
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Surge Rating(20s) row
Read from the PILF30W12V120V row of the manual's DC wiring table (maximum fusing guide); the table notes that the fuse size must be smaller than the maximum cable rating, but large enough for full inverter performance.
Where: PDF page 15, 3.3 DC Wiring & Fusing table, PILF30W12V120V row
Printed as 3000 in the 3012 column (column 6 of 7) of the spec sheet, whose columns are headed 0612, 1012, 1512, 2012, 2412, 3012, 4012, and as "Continuous Power Watt 3000" on the store page; 3000 W expressed in kW.
Where: PDF page 25, Appendix 1 - PILF Series Spec Sheet, Continuous Power row; store page Specifications tab
30.38 L* (Calculated from published dimensions)W: 344 × H: 184 × L: 480 mm / W: 13.5 × H: 7.24 × L: 18.9 inWeight26 kg / 57 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
Linked from the Manual tab of AIMS Power's product page; captured Nov 2, 2026 (archived copy).
Location: PDF page 15, 3.3 DC Wiring & Fusing; PDF pages 16 and 17, AC wiring and grounding; PDF page 25, Appendix 1 - PILF Series Spec Sheet
Retrieved Nov 2, 2026
The PILF Series user's manual (file dated 071725), linked from the Manual tab of AIMS Power's product page and fetched directly from www.aimscorp.net with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 10:45:31.538 UTC). Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
AIMS Power store page; captured Nov 2, 2026 (archived copy).
Location: Specifications tab; Additional information table; Manual tab
Retrieved Nov 2, 2026
AIMS Power's own store page for the PILF30W12V120V on www.aimscorp.net (its Additional information, Specifications and Manual tabs), fetched directly with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 09:50:43.499 UTC). A product page, cited as such; manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
PILF Series DC to AC Power Inverter User's Manual (071725) (November 2, 2026 capture)
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].