About brandDesigns and sells off-grid and renewable energy equipment: DC to AC inverters, solar panels, deep-cycle batteries, solar charge controllers, cables, fuse kits and portable generators. AIMS Power says it was founded by Bruce de Jong, who built its first inverter in 2001.
SKU detail
locator: Store page Quick Comparison, SKU row; manual model table
The store page prints "Output voltage 100-110-120Vac" and its features "Single phase 120Vac output"; the manual prints "100-110-120Vac / 220-230-240Vac" for the series.
The store page prints a lower idle consumption. AIMS Power's ETL 4-6 kW manual prints 90 W idle (power saver off) for the PICOGLF6024120UL; the store page prints 52.5 W. The manual value is recorded.
The manual prints "PICOGLF6024120UL 90W 25W" (Power Saver Off, Power Saver On (3Secs)); 25 W applies with power saver on.
Where: PDF page 12, idle consumption table, PICOGLF6024120UL row
Sources
52.5 W
The store page prints "Idle consumption: 52.5 watts" and "Idle consumption with power saver mode ON: <25 watts".
ETL certified to UL 1741 and CSA C22.2 No. 107.1 (manual); listed to UL 458, 1741, 1012 and CSA 22.2 No. 107.1 & 107.2 (store page)
The manual cover prints "ETL Certified to UL 1741 & CSA STDC 22.2 NO. 107.1"; the page prints "Listed to UL 458, 1741, 1012 and CSA 22.2 NO. 107.1 & 107.2". A claim in the maker's documents; no certificate or listing record was read.
Printed as "Model PICOGLF40W PICOGLF60W Continuous Output Power 4000W 6000W"; 6000 W expressed in kW. The page prints "Continuous output power: 6000 Watts".
Printed on the store page as "Ambient operating temperature: 14°F to 122°F (-10°C to 50°C)"; the manual prints no ambient range in its specification table.
Where: Specifications tab, Ambient Operating Temperature
40.5 L* (Calculated from published dimensions)W: 415 × H: 200 × L: 488 mm / W: 16.3 × H: 7.87 × L: 19.2 inWeight49 kg / 110 lb
Evidence score
3/100Missing details40% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term2 years2.4 / 30.0
2 years is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 25 years, the best documented for an inverter, printed by the maker: APsystems DS3
The spec sheet prints "Standard Warranty 2 Year" and the warranty section "You have a full 2 Year warranty from date of purchase"; the page's Specifications tab prints "2 Year warranty".
The maker's documents disagree; the less favorable printed figure, 2 years, is scored. Warning: The store page prints two warranty terms
90 W is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 1 W, the lowest documented for an inverter in the 3.5 to 7 kW output band, printed by the maker: Fronius Primo 3.8-1 208-240. The bar is a printed bound: less than 1 W, as printed.
The manual prints "PICOGLF6024120UL 90W 25W" (Power Saver Off, Power Saver On (3Secs)); 25 W applies with power saver on.
The maker's documents disagree; the less favorable printed figure, 90 W, is scored. Warning: The store page prints a lower idle consumption
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
2 years Check note
The store page prints two warranty terms. AIMS Power's ETL 4-6 kW manual and the page's Specifications tab print 2 years; the page's Additional information table prints 3 years. The manual value is recorded.
The spec sheet prints "Standard Warranty 2 Year" and the warranty section "You have a full 2 Year warranty from date of purchase"; the page's Specifications tab prints "2 Year warranty".
Where: PDF page 30, Appendix 1, Standard Warranty; Warranty section
Sources
3 years
The store page's Additional information table prints "Warranty 3 Year" and its description a 3 year warranty.
AIMS Power's user manual for its ETL certified 4 kW and 6 kW 24 V Global LF inverter chargers (PICOGLF4024120UL, PICOGLF4024240SUL, PICOGLF6024120UL, PICOGLF6024240SUL and their C versions), linked from the PICOGLF6024120UL store page's Manual tab, captured on October 17, 2026. Its spec sheet (PDF pages 29 and 30) has a PICOGLF40W column and a PICOGLF60W column; only the PICOGLF60W column is read. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
AIMS Power's own store page on aimscorp.net, captured on October 17, 2026; the content is whatever the address served on that date. Its Specifications tab and Additional information table are read for this SKU only; the Quick Comparison table lists other models and is read only in this SKU's column. The page carries no revision date. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Global LF Series Pure Sine Wave Inverter Charger User's Manual, Version 2.0, PICOGLF4KW & 6KW, ETL certified (AIMS Power, file CETL 4-6K MANUAL ENGLISH 09172018)
Archived copy of a document published by AIMS Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 90
unit: Unknown
shown: 90 W
shown detail: Unknown
state: documented
points: 0.1
ceiling: 10
weight: 10
share: 1.1
covered: yes
missing: no
folded: no
reason: documents-disagree